5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: TT-UKK5-M-F/60AC
Code: 2788210
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
LAST VIEWED
| Product type | Surge protection for MCR technology |
| IEC test classification | C1 |
| C2 | |
| D1 | |
| Type | Double-level terminal block with disconnect knife |
| Number of positions | 1 |
| Surge protection fault message | none |
| Wire pairs per module | 1 |
| Insulation characteristics | |
| Overvoltage category | III |
| Pollution degree | 2 |
| Nominal voltage UN | 60 V AC |
| Connection method | Screw connection |
| Screw thread | M3 |
| Tightening torque | 0.8 Nm |
| Conductor cross section flexible | 0.2 mm² ... 4 mm² |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Width | 6.2 mm |
| Height | 80 mm |
| Depth | 68 mm |
| Flammability rating according to UL 94 | V-0 |
| Housing material | PA 6.6 |
| Mechanical data | |
| Open side panel | No |
| Direction of action | Line-Line |
| Maximum continuous voltage UC | 30 V DC |
| 120 V AC | |
| Rated current | 2 A AC (85 °C) |
| 300 mA DC (85 °C) | |
| Operating effective current ICat UC | ≤ 2 µA |
| Nominal discharge current In(8/20) µs (line-line) | 5 kA |
| Total discharge current Itotal(8/20) µs | 5 kA |
| Max. discharge current Imax(8/20) µs maximum (line-line) | 5 kA |
| Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 650 V |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 650 V |
| Voltage protection level Up(line-line) | ≤ 650 V (C2 - 10 kV / 5 kA) |
| Response time tA(line-line) | ≤ 100 ns |
| Capacity (Core-Core) | typ. 2 pF |
| Surge protection fault message | none |
| Max. required back-up fuse | 2 A AC (F) |
| 315 mA DC (F) | |
| Impulse durability (line-line) | C2 - 10 kV / 5 kA |
| Alternating current carrying capacity (line-line) | 2.5 A - 1 s |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Standards/specifications | IEC 61643-21 |
| Note | 2000 |
| Standards/specifications | EN 61643-21 |
| Note | 2001 |
| Mounting type | DIN rail: 35 mm |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP