OMRON E5C2-R20P-D 100-240VAC 0-50 E5C26026D E5C2R20PDAC100240050 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

E5C2-R20P-D 100-240VAC 0-50 E5C26026D E5C2R20PDAC100240050 OMRON ON/OFF Pt 0-50 ° C 48x48

Reference: E5C2-R20P-D 100-240VAC 0-50

Code: E5C26026D

Catalog Number: E5C2R20PDAC100240050

Manufacturer: OMRON

Description:

ON/OFF Pt 0-50 ° C 48x48
ON/OFF Pt 0-50ºC 48x48
Temp. controller, LITE, 1/16 DIN, 48x48mm,Dial knob,On-Off Control,Pt100,0-50deg.,100-240V AC

Categories:

  • Relays > Temperature monitoring relay
  • OMRON > Temperature and Processes > E5C2

Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 125,21 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 4-5 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Features

Easy-to-use, basic temperature controller with analogue dial setting

Omron's basic ON/OFF or PD controller features an analogue setting dial. This compact, low-cost controller has a setting accuracy of 2% of full scale. It incorporates a plug-in socket allowing for DIN-rail or flush mounting.

  • Compact, cost-effective controller
  • Control mode: ON/OFF or P
  • Control output: relay
  • Power supply: 100-120 / 200-240VAC
  • Thermocouple K: 0 to 1200°C, L: 0 to 400°C, Pt100: -50 to 200°C

Applications

ON/OFF control

Hot water supply provided by a boiler can be simply controlled with an E5C2. The water temperature is set by the big and easy to operate dial on the front of the controller.

Ordering information

Standard models (Power supply: 100 to 240 VAC)

Input

Control method

On/OFF

Proportional (P)

Output/Indication method

Relay/No indication

Input/ standard scale (°C)

Thermocouple

K (CA) Chromel vs. Alumel

0 to 200 °C

E5C2-R20K AC100-240 0-200

E5C2-R40K AC100-240 0-200

0 to 300 °C

-

E5C2-R40K AC100-240 0-300

0 to 400 °C

E5C2-R20K AC100-240 0-400

E5C2-R40K AC100-240 0-400

0 to 600 °C

E5C2-R20K AC100-240 0-600

E5C2-R40K AC100-240 0-600

0 to 800 °C

E5C2-R20K AC100-240 0-800

E5C2-R40K AC100-240 0-800

0 to 1000 °C

E5C2-R20K AC100-240 0-1000

-

0 to 1200 °C

E5C2-R20K AC100-240 0-1200

-

J (IC) Iron versus Constantan

0 to 200 °C

E5C2-R20J AC100-240 0-200

-

0 to 300 °C

E5C2-R20J AC100-240 0-300

-

0 to 400 °C

E5C2-R20J AC100-240 0-400

-

Resistance thermometer

Platinum resistance thermometer

-50 to 50 °C

E5C2-R20P-D AC100-240 -50-50

-

0 to 50 °C

E5C2-R20P-D AC100-240 0-50

-

0 to 100 °C

E5C2-R20P-D AC100-240 0-100

-

0 to 200 °C

E5C2-R20P-D AC100-240 0-200

-

0 to 300 °C

E5C2-R20P-D AC100-240 0-300

-

0 to 400 °C

E5C2-R20P-D AC100-240 0-400

-

Thermistor

THE (replaceable element)

0 to 100 °C

E5C2-R20G AC100-240 0-100

-

100 to 200 °C

E5C2-R20G AC100-240 100-200

-

150 to 300 °C

E5C2-R20G AC100-240 150-300

-

Input ranges

Thermocouple1

Platinum resistance thermometer

Thermistor2

K (CA) chromel vs. alumel

J (IC) iron vs. constantan

Pt100

THE

°C

0 to 200 (5),
0 to 400 (10),
0 to 600 (20),
0 to 800 (20),
0 to 1,000 (25),
0 to 1,200 (25)

0 to 200 (5),
0 to 300 (10),
0 to 400 (10)

-50 to 50 (2),
0 to 50 (1),
0 to 100 (2),
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)

0 to 100 (2) (6 kΩ at 0°C),
100 to 200 (2) (550 Ω ☐ 200°C)

150 to 300 (2) (4 kΩ ☐ 200°C)

Accessories

Functions

Order code

Front connecting socket with finger protection

P2CF-08-E

Back connecting socket (for flush mounting)

P3G-08

Finger protection cover (for P3G-08)

Y92A-48G

Protective front cover (IP66)

Y92A-48B

Specifications

Supply voltage

100 to 240 VAC, 50/60 Hz

Thermocouple input type

K, J (with sensor break detection)

RTD input type

Pt100, THE

Control mode

ON/OFF or P control

Setting method

analog setting

Output

Relay, SPDT, 3 A at 250 VAC

Life expectancy

Electrical: 100,000 operations min.

Setting accuracy

±2% FS max.

Hysteresis

Approx. 0.5% FS (fixed)

Proportional band

3% FS (fixed)

Reset range

5 ±1% FS min.

Control period

20 s

IP Rating front panel

IP40 (IP66 cover available)

IP rating terminals

IP00

Ambient temperature

-10 to 55°C

Size in mm (HxWxD)

48×48×96


1.Values in ( ) are the minimum unit.

2.Values in ( ) are the thermistor resistive value.

ETIM for 378354 Relays (EC001446)

Feature nameVoltage type (operating voltage) (EF005294)
Feature valueAC
Feature nameType of electric connection (EF003961)
Feature valuePlug-in connection
Feature nameVoltage type (supply voltage) (EF002991)
Feature valueAC
Feature nameError registration possible (EF003423)
Feature valueNo
Feature nameExternal reset possible (EF003426)
Feature valueNo
Feature nameWith detachable clamps (EF003340)
Feature valueNo
Feature nameNumber of contacts as change-over contact (EF008257)
Feature value1
Feature nameNumber of contacts as normally open contact (EF008256)
Feature value0
Feature nameWidth (EF000008)
Feature value48 mm
Feature nameNumber of contacts as normally closed contact (EF008255)
Feature value0
Feature nameNumber of measuring circuits (EF003425)
Feature value1
Feature nameHeight (EF000040)
Feature value48 mm
Feature nameDepth (EF000049)
Feature value101.7 mm
Feature nameSupply voltage AC 50 Hz (EF007532)
Feature value100 V
Feature nameSupply voltage AC 60 Hz (EF007533)
Feature value100 V

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.