EATON - MOELLER SWD4-3LF8-24-2S 116027 Y7-116027 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

SWD4-3LF8-24-2S 116027 Y7-116027 EATON ELECTRIC Flat cable, SmartWire-DT, 3m, 8-Pole, prefabricated with 2 b..

Reference: SWD4-3LF8-24-2S

Code: 116027

Catalog Number: Y7-116027

Manufacturer: EATON - MOELLER

Description:

Flat cable, SmartWire-DT, 3m, 8-Pole, prefabricated with 2 blade terminals SWD4-8MF2
SWD4-3LF8-24-2S
Eaton SWD4 Flat cable, SmartWire-DT, 3 m, 8-Pole, prefabricated with 2 blade terminals SWD4-8MF2
SmartWire-DT ribbon cable for connecting SmartWire-DT participants within the control panel, 3 m, 8-Pole, prefabricated with 2 blade terminals SWD4-8MF2

Categories:

  • Cables > Data and communication cable
  • EATON - MOELLER > Smartwire Darwin

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 24,77 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

General specifications

Product Name
Eaton SWD4 Accessory Flat cable
Catalog Number
116027
Model Code
SWD4-3LF8-24-2S
EAN
4015081157679
Product Length/Depth
90 mm
Product Height
22 mm
Product Width
90 mm
Product Weight
0.11 kg
Certifications
UL
UL File No.: E29184
UL Category Control No.: NKCR
CSA File No.: 2324643
CSA Class No.: 3211-07
CSA

Features & Functions

Fitted with:
2 blade terminals SWD4-8MF2
Functions
For connecting the SmartWire-DT modules within the control panel

General

Cable length
3 m
Number of Poles
Eight-pole
Outer diameter - approximate
17.5 mm
Outer sheath material
Polyvinyl chloride (PVC)
Permitted bending radius, moving application with forced guidance - min
15 mm
Product category
SmartWire-DT accessories
Suitable as
Signaling cable

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Safety

Flame retardant
In accordance with EN 60332-1-2

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 116027 Cable (EC003249)

Feature nameCable type (EF000081)
Feature valueOther
Feature nameDuplex (EF023003)
Feature valueNo
Feature nameConductor material (EF001622)
Feature valueOther
Feature nameConductor surface (EF010804)
Feature valueTinned
Feature nameDiameter conductor (EF001621)
Feature value1.35 mm
Feature nameNominal cross section conductor (EF000060)
Feature value0.23 mm²
Feature nameAWG size (EF011789)
Feature value24
Feature nameConductor category (EF001632)
Feature valueClass 2 = stranded
Feature nameNumber of cores (EF001792)
Feature value8
Feature nameNumber of stranding elements (EF001688)
Feature value0
Feature nameStranding element (EF001617)
Feature valueNo
Feature nameMaterial core insulation (EF000061)
Feature valuePolyvinyl chloride (PVC)
Feature nameSpecification core insulation (EF011805)
Feature valueOther
Feature nameCore identification according to HD 308 S2 (EF013766)
Feature valueNo
Feature nameCore identification (EF000067)
Feature valueColour
Feature nameScreen over stranding element (EF001623)
Feature valueNone
Feature nameStranding (EF003802)
Feature valueOther
Feature nameScreen over stranding (EF001624)
Feature valueNone
Feature nameLongitudinal water blocking cable (EF011011)
Feature valueNo
Feature nameRadial water blocking cable (EF011012)
Feature valueNo
Feature nameSuitable for underground installation (EF003689)
Feature valueNo
Feature nameApproved type of underground installation (EF015176)
Feature valueOther
Feature nameProtective sheath (EF001691)
Feature valueOther
Feature nameMaterial outer sheath (EF001625)
Feature valuePolyvinyl chloride (PVC)
Feature nameSpecification material outer sheath (EF011806)
Feature valueOther
Feature nameColour outer sheath (EF001618)
Feature valueGreen
Feature nameNumber of sheath layers (EF016997)
Feature value0
Feature nameArmouring/reinforcement (EF001683)
Feature valueNone
Feature nameMaterial armouring (EF013440)
Feature valueOther
Feature nameCable geometry (EF013532)
Feature valueFlat
Feature nameFlame retardant according to IEC 60332-1-2 (EF016492)
Feature valueNo
Feature nameFlame retardant according to IEC 60332-3-21 (Cat A F/R) (EF016493)
Feature valueNo
Feature nameFlame retardant according to IEC 60332-3-22 (Cat A) (EF016494)
Feature valueNo
Feature nameFlame retardant according to IEC 60332-3-23 (Cat B) (EF016495)
Feature valueNo
Feature nameFlame retardant according to IEC 60332-3-24 (Cat C) (EF016496)
Feature valueNo
Feature nameFlame retardant according to IEC 60332-3-25 (Cat D) (EF016497)
Feature valueNo
Feature nameLow smoke according to EN IEC 61034-2 (EF003799)
Feature valueNo
Feature nameHalogen free according to EN IEC 60754-1 (EF016498)
Feature valueNo
Feature nameHalogen free according to EN IEC 60754-2 (EF003792)
Feature valueNo
Feature nameHalogen free according to EN IEC 60754-3 (EF016500)
Feature valueNo
Feature nameReaction-to-fire according to EN 13501-6: Class (EF011577)
Feature valueNone
Feature nameReaction-to-fire according to EN 13501-6: Smoke production (EF011578)
Feature valueNone
Feature nameReaction-to-fire according to EN 13501-6: Flaming droplets/particles (EF011579)
Feature valueNone
Feature nameReaction-to-fire according to EN 13501-6: Acidity (EF011580)
Feature valueNone
Feature nameCircuit integrity according to IEC 60331-23 (EF016619)
Feature valueNo
Feature nameOil resistant according to EN IEC 60811-404 (EF009770)
Feature valueNo
Feature nameOuter diameter approx. (EF003921)
Feature value17.5 mm
Feature nameMin. permitted bending radius, moving application with forced guidance (EF011801)
Feature value15 mm
Feature nameMin. permitted bending radius, moving application/free movement (EF011802)
Feature value15 mm
Feature nameMin. permitted bending radius, stationary application/permanent installation (EF011803)
Feature value7.5 mm
Feature namePermitted cable outer temperature during assembling/handling (EF001685)
Feature value-10 °C
Feature namePermitted cable outer temperature after assembling without vibration (EF001686)
Feature value-30 °C
Feature nameCategory (EF001619)
Feature valueOther
Feature nameNVP value (EF008387)
Feature value66.7 %
Feature nameCertified for shipboard application (EF013772)
Feature valueNo
Feature nameSuitable as telephone cable (EF013768)
Feature valueNo
Feature nameSuitable as computer data cable (EF013769)
Feature valueNo
Feature nameSuitable as signalling cable (EF013770)
Feature valueYes
Feature nameSuitable for use as security alarm cable (EF017089)
Feature valueNo
Feature nameDrain wire (EF001029)
Feature valueNo
Feature nameWith rip cord (EF017088)
Feature valueNo
Feature nameCable width approx. (EF003796)
Feature value17.5 mm
Feature nameCable height approx. (EF003797)
Feature value22 mm
Feature nameCharacteristic impedance (EF001628)
Feature value100 Ohm
Feature nameMax. tensile strength during installation (EF013801)
Feature value0.0115 kN
Feature nameNominal voltage U (EF001615)
Feature value24 V
Feature nameWith rodent protection (EF007960)
Feature valueNo
Feature nameCompatible with Grade2TV according to XP-C 90-483 (EFFR0001)
Feature valueNo
Feature nameCompatible with Grade3TV according to XP-C 90-483 (EFFR0002)
Feature valueNo

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.