6ES7516-3AN01-0AB0 SIEMENS *** Spare part *** SIMATIC S7-1500, CPU 1516-3 PN/DP, central processing unit wit.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

6ES7516-3AN01-0AB0 SIEMENS *** Spare part *** SIMATIC S7-1500, CPU 1516-3 PN/DP, central processing unit wit..

6ES7516-3AN01-0AB0

SIEMENS

*** Spare part *** SIMATIC S7-1500, CPU 1516-3 PN/DP, central processing unit with work memory 1 MB for program and 5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFIBUS, 10 ns bit performance, SIMATIC Memory Card required

More details


AUTOMATION SYSTEMS > SIMATIC S7-1500 / F Safety / RH Redundant / Open Controller / Software Controller (without I / O)

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC000236 - PLC CPU-module

Value Unit
Category according to EN 954-1 (EF006782) -
Performance level according to EN ISO 13849-1 (EF007399) -
Supply voltage AC 60 Hz (EF007533) -V
Supply voltage AC 50 Hz (EF007532) -V
SIL according to IEC 61508 (EF009889) -
Supply voltage DC (EF007534) ['19.2', '28.8']V
Voltage type of supply voltage (EF002991) DC
Number of relay outputs (EF007348) 0
Max. number of time switches (EF007349) -
Model (EF000010) Modular
Processing time (1K, binary operation) (EF003004) 0.01ms
Number of HW-interfaces industrial Ethernet (EF003020) 2
Number of interfaces PROFINET (EF006932) 2
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 1
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 0
Number of analogue outputs (EF001995) 0
Number of analogue inputs (EF001994) 0
Number of digital inputs (EF001992) 0
Number of digital outputs (EF001993) 0
With optical interface (EF003028) false
Supporting protocol for TCP/IP (EF003050) true
Supporting protocol for PROFIBUS (EF003052) true
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) true
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET IO (EF007525) true
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) false
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) false
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
System accessory (EF004118) true
Redundancy (EF003156) false
With display (EF000458) true
Type of memory (EF002996) Other
Memory size (EF002997) 6000.0kByte
Additional program memory possible (EF003029) false
Rail mounting possible (EF003972) true
Wall mounting/direct mounting (EF007020) false
Front build in possible (EF007016) false
Rack-assembly possible (EF007018) false
Suitable for safety functions (EF001597) false
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust (EF003998) None
Width (EF000008) 70.0mm
Height (EF000040) 147.0mm
Depth (EF000049) 129.0mm


*** Spare part *** SIMATIC S7-1500, CPU 1516-3 PN/DP, central processing unit with work memory 1 MB for program and 5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFIBUS, 10 ns bit performance, SIMATIC Memory Card required
General information
Product type designationCPU 1516-3 PN/DP
HW functional statusFS03
Firmware versionV2.8
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central)
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV16 (FW V2.8) / V13 SP1 Update 4 (FW V1.8) or higher
Configuration control
via datasetYes
Display
Screen diagonal [cm]6.1 cm
Control elements
Number of keys6
Mode selector switch1
Supply voltage
Type of supply voltage24 V DC
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
● Mains/voltage failure stored energy time5 ms
● Repeat rate, min.1/s
Input current
Current consumption (rated value)0.85 A
Inrush current, max.2.4 A; Rated value
I²t0.02 A²·s
Power
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)6.7 W
Power loss
Power loss, typ.7 W
Memory
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
● integrated (for program)1 Mbyte
● integrated (for data)5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
● maintenance-freeYes
CPU processing times
for bit operations, typ.10 ns
for word operations, typ.12 ns
for fixed point arithmetic, typ.16 ns
for floating point arithmetic, typ.64 ns
CPU-blocks
Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range0 ... 65 535
● Size, max.1 Mbyte
FC
● Number range0 ... 65 535
● Size, max.1 Mbyte
OB
● Size, max.1 Mbyte
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 250 µs
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of isochronous mode OBs3
● Number of technology synchronous alarm OBs2
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
Nesting depth
● per priority class24
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
IEC counter
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 times
● Number2 048
Retentivity
— adjustableYes
IEC timer
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Extended retentive data area (incl. timers, counters, flags), max.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Number, max.16 kbyte
● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustableYes
● Retentivity presetNo
Local data
● per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules8 192; max. number of modules / submodules
I/O address area
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
● Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● integrated1
● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated2
● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max.32; CPU + 31 modules
● Number of lines, max.1
PtP CM
● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
● Number16
Clock synchronization
● supportedYes
● to DP, masterYes
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces2
Number of PROFIBUS interfaces1
1. Interface
Interface types
● Number of ports2
● integrated switchYes
● RJ 45 (Ethernet)Yes; X1
Protocols
● IP protocolYes; IPv4
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● SIMATIC communicationYes
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyYes
PROFINET IO Controller
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeYes
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTYes
— MRPYes; MRP Automanager acc. to IEC 62439-2 Edition 2.0; MRP Manager; MRP Client; max. number of devices in the ring: 50
— MRPDYes; Requirement: IRT
— PROFIenergyYes; per user program
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeNo
— IRTYes
— MRPYes; MRP Automanager acc. to IEC 62439-2 Edition 2.0; MRP Manager; MRP Client; max. number of devices in the ring: 50
— MRPDYes; Requirement: IRT
— PROFIenergyYes; per user program
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— Asset management recordYes; per user program
2. Interface
Interface types
● Number of ports1
● integrated switchNo
● RJ 45 (Ethernet)Yes; X2
Protocols
● IP protocolYes; IPv4
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● SIMATIC communicationYes
● Open IE communicationYes; Optionally also encrypted
● Web serverYes
● Media redundancyNo
PROFINET IO Controller
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeNo
— Direct data exchangeNo
— IRTNo
— MRPNo
— MRPDNo
— PROFIenergyYes; per user program
— Prioritized startupNo
— Number of connectable IO Devices, max.32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max.32
— of which in line, max.32
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeNo
— IRTNo
— MRPNo
— MRPDNo
— PROFIenergyYes; per user program
— Prioritized startupNo
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— Asset management recordYes; per user program
3. Interface
Interface types
● Number of ports1
● RS 485Yes; X3
Protocols
● PROFIBUS DP masterYes
● PROFIBUS DP slaveNo
● SIMATIC communicationYes
Interface types
RJ 45 (Ethernet)
● 100 MbpsYes
● AutonegotiationYes
● AutocrossingYes
● Industrial Ethernet status LEDYes
RS 485
● Transmission rate, max.12 Mbit/s
Protocols
Number of connections
● Number of connections, max.256; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces128
● Number of S7 routing paths16
Redundancy mode
● H-Sync forwardingYes
Media redundancy
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC communication
● S7 communication, as serverYes
● S7 communication, as clientYes
● User data per job, max.See online help (S7 communication, user data size)
Open IE communication
● TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
● UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; Max. 5 multicast circuits
● DHCPNo
● SNMPYes
● DCPYes
● LLDPYes
Web server
● HTTPYes; Standard and user pages
● HTTPSYes; Standard and user pages
PROFIBUS DP master
● Number of connections, max.48; for the integrated PROFIBUS DP interface
Services
— PG/OP communicationYes
— S7 routingYes
— Data record routingYes
— Isochronous modeYes
— EquidistanceYes
— Number of DP slaves125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Activation/deactivation of DP slavesYes
OPC UA
● Runtime license requiredYes
● OPC UA ClientYes
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of connections, max.10
— Number of nodes of the client interfaces, max.2 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions per connection (except OPC_UA_ReadList,OPC_UA_WriteList,OPC_UA_MethodCall), max.1
— Number of simultaneous calls of the client instructions OPC_UA_ReadList,OPC_UA_WriteList and OPC_UA_MethodCall, max.5
— Number of registerable nodes, max.5 000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of sessions, max.48
— Number of accessible variables, max.100 000
— Number of registerable nodes, max.20 000
— Number of subscriptions per session, max.20
— Sampling interval, min.100 ms
— Publishing interval, min.200 ms
— Number of server methods, max.50
— Number of inputs/outputs per server method, max.20
— Number of monitored items, max.2 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10; or 20, depending on type of server interface
— Number of nodes for user-defined server interfaces, max.5 000
Further protocols
● MODBUSYes; MODBUS TCP
Isochronous mode
EquidistanceYes
S7 message functions
Number of login stations for message functions, max.64
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.5 000
Number of simultaneously active program alarms
● Number of program alarms1 000
● Number of alarms for system diagnostics200
● Number of alarms for motion technology objects160
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 8 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
Status/control
● Status/control variableYes
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
● Forcing, variablesPeripheral inputs/outputs
● Number of variables, max.200
Diagnostic buffer
● presentYes
● Number of entries, max.3 200
— of which powerfail-proof500
Traces
● Number of configurable Traces4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LEDYes
● ERROR LEDYes
● MAINT LEDYes
● Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes; Note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER
● Number of available Motion Control resources for technology objects2 400
● Required Motion Control resources
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
● Positioning axis
— Number of positioning axes at motion control cycle of 4 ms (typical value)7
— Number of positioning axes at motion control cycle of 8 ms (typical value)14
Controller
● PID_CompactYes; Universal PID controller with integrated optimization
● PID_3StepYes; PID controller with integrated optimization for valves
● PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counterYes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
● vertical installation, min.0 °C
● vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
● min.-40 °C
● max.70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Configuration
Programming
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— GRAPHYes
Know-how protection
● User program protection/password protectionYes
● Copy protectionYes
● Block protectionYes
Access protection
● Password for displayYes
● Protection level: Write protectionYes
● Protection level: Read/write protectionYes
● Protection level: Complete protectionYes
Cycle time monitoring
● lower limitadjustable minimum cycle time
● upper limitadjustable maximum cycle time
Dimensions
Width70 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.845 g
last modified:08/25/2020


Product
Article Number (Market Facing Number)6ES7516-3AN01-0AB0
Product Description*** Spare part *** SIMATIC S7-1500, CPU 1516-3 PN/DP, central processing unit with work memory 1 MB for program and 5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFIBUS, 10 ns bit performance, SIMATIC Memory Card required
Product familyNot available
Product Lifecycle (PLM)PM410:Product cancellation
PLM Effective DateProduct is cancelled since: 02.06.2020
Notes
For this product a successor is available6ES7516-3AN02-0AB0
This product is a Spare Part, please visit the Spares & Service section for more information
If you need assistance please contact our local Siemens office
Successor information
Successor6ES7516-3AN02-0AB0
Successor DescriptionSIMATIC S7-1500, CPU 1516-3 PN/DP, central processing unit with 1 MB work memory for program and 5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFIBUS, 10 ns bit performance, SIMATIC Memory Card required
Price data
Price Group215
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsECCN : EAR99H / AL : N
Standard lead time ex-works1 Day/Days
Net Weight (kg)0,907 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension15,80 x 15,90 x 8,40
Package size unit of measureCM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047623404958
UPC804766167720
Commodity Code85371091
LKZ_FDB/ CatalogIDST9-E5
Product Group4500
Group CodeR111
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 03.08.2015
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

4,4'-isopropylidenediphenol (Bisphenol A, BPA)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
Not available

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.