6AG1134-6JD00-2CA1 SIEMENS SIPLUS ET 200SP, Analog input module, AI 4xRTD/TC High Feature, -40...+60°C start.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

6AG1134-6JD00-2CA1 SIEMENS SIPLUS ET 200SP, Analog input module, AI 4xRTD/TC High Feature, -40...+60°C start..

6AG1134-6JD00-2CA1

SIEMENS

SIPLUS ET 200SP, Analog input module, AI 4xRTD/TC High Feature, -40...+60°C start up -25°C with conformal coating based on 6ES7134-6JD00-0CA1. suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.1% , 2-/3-/4-wire

SIPLUS ET 200SP, analog input, EA 4XRTD/TC HIGH FEATURE, -40 ... +60 ° C with coating formed based on 6ES7134-6JD00-0CA1 . Suitable for type BU A0, A1, color code CC00, channel Diagnosis, 16bit, +/-0,1%, 2-/3-/4-threads

More details


AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $749.68
Unit price: $749.68
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001596 - Fieldbus, decentr. periphery - analogue I/O module

Value Unit
Explosion safety category for gas (EF003997) -
Supply voltage AC 50 Hz (EF007532) -V
Performance level according to EN ISO 13849-1 (EF007399) -
SIL according to IEC 61508 (EF009889) -
Type of electric connection (EF003961) -
Supply voltage AC 60 Hz (EF007533) -V
Category according to EN 954-1 (EF006782) -
Degree of protection (NEMA) (EF011959) -
Explosion safety category for dust (EF003998) -
Supply voltage DC (EF007534) ['19.2', '28.8']V
Voltage type of supply voltage (EF002991) DC
Input, current (EF003204) false
Input, voltage (EF003205) true
Input, resistor (EF003206) true
Input, resistance thermometer (EF003207) true
Input, thermocouple (EF003208) true
Input signal, configurable (EF003209) true
Resolution of the analogue inputs (EF003575) 16Bit
Output, current (EF003212) -
Output, voltage (EF003213) -
Output signal configurable (EF003214) -
Resolution of the analogue outputs (EF003577) -Bit
Number of analogue inputs (EF001994) 4
Number of analogue outputs (EF001995) 0
Analogue inputs configurable (EF008518) true
Analogue outputs configurable (EF008519) -
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) -
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
Supporting protocol for TCP/IP (EF003050) false
Supporting protocol for PROFIBUS (EF003052) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET IO (EF007525) false
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) false
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) false
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
System accessory (EF004118) true
Degree of protection (IP) (EF005474) IP20
Fieldbus connection over separate bus coupler possible (EF004002) true
Rail mounting possible (EF003972) true
Wall mounting/direct mounting (EF007020) false
Front build in possible (EF007016) true
Rack-assembly possible (EF007018) true
Suitable for safety functions (EF001597) false
Appendant operation agent (Ex ia) (EF004141) -
Appendant operation agent (Ex ib) (EF004142) -
Width (EF000008) 15.0mm
Height (EF000040) 73.0mm
Depth (EF000049) 58.0mm


SIPLUS ET 200SP, Analog input module, AI 4xRTD/TC High Feature, -40...+60°C start up -25°C with conformal coating based on 6ES7134-6JD00-0CA1. suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.1% , 2-/3-/4-wire
General information
Product type designationAI 4xRTD/TC 2-/3-/4-wire HF
usable BaseUnitsBU type A0, A1
Color code for module-specific color identification plateCC00
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeNo
Operating mode
● OversamplingNo
● MSINo
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Input current
Current consumption, max.35 mA
Power loss
Power loss, typ.0.75 W
Address area
Address space per module
● Address space per module, max.8 byte; + 1 byte for QI information
Analog inputs
Number of analog inputs4
● For voltage measurement4
● For resistance/resistance thermometer measurement4
● For thermocouple measurement4
permissible input voltage for voltage input (destruction limit), max.30 V
Constant measurement current for resistance-type transmitter, typ.0.7 mA; 1.7 mA for Cu10 sensors
Cycle time (all channels), min.Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels); for line compensation in case of a three-wire connection, an additional cycle is necessary
Technical unit for temperature measurement adjustableYes; °C/°F/K
Input ranges (rated values), voltages
● -1 V to +1 VYes; 16 bit incl. sign
— Input resistance (-1 V to +1 V)1 MΩ
● -250 mV to +250 mVYes; 16 bit incl. sign
— Input resistance (-250 mV to +250 mV)1 MΩ
● -50 mV to +50 mVYes; 16 bit incl. sign
— Input resistance (-50 mV to +50 mV)1 MΩ
● -80 mV to +80 mVYes; 16 bit incl. sign
— Input resistance (-80 mV to +80 mV)1 MΩ
Input ranges (rated values), thermocouples
● Type BYes; 16 bit incl. sign
— Input resistance (Type B)1 MΩ
● Type CYes; 16 bit incl. sign
— Input resistance (Type C)1 MΩ
● Type EYes; 16 bit incl. sign
— Input resistance (Type E)1 MΩ
● Type JYes; 16 bit incl. sign
— Input resistance (type J)1 MΩ
● Type KYes; 16 bit incl. sign
— Input resistance (Type K)1 MΩ
● Type LYes; 16 bit incl. sign
— Input resistance (Type L)1 MΩ
● Type NYes; 16 bit incl. sign
— Input resistance (Type N)1 MΩ
● Type RYes; 16 bit incl. sign
— Input resistance (Type R)1 MΩ
● Type SYes; 16 bit incl. sign
— Input resistance (Type S)1 MΩ
● Type TYes; 16 bit incl. sign
— Input resistance (Type T)1 MΩ
● Type UYes; 16 bit incl. sign
— Input resistance (Type U)1 MΩ
● Type TXK/TXK(L) to GOSTYes; 16 bit incl. sign
— Input resistance (Type TXK/TXK(L) to GOST)1 MΩ
Input ranges (rated values), resistance thermometer
● Cu 10Yes; 16 bit incl. sign
● Ni 100Yes; 16 bit incl. sign
— Input resistance (Ni 100)1 MΩ
● Ni 1000Yes; 16 bit incl. sign
— Input resistance (Ni 1000)1 MΩ
● LG-Ni 1000Yes; 16 bit incl. sign
— Input resistance (LG-Ni 1000)1 MΩ
● Ni 120Yes; 16 bit incl. sign
— Input resistance (Ni 120)1 MΩ
● Ni 200Yes; 16 bit incl. sign
— Input resistance (Ni 200)1 MΩ
● Ni 500Yes; 16 bit incl. sign
— Input resistance (Ni 500)1 MΩ
● Pt 100Yes; 16 bit incl. sign
— Input resistance (Pt 100)1 MΩ
● Pt 1000Yes; 16 bit incl. sign
— Input resistance (Pt 1000)1 MΩ
● Pt 200Yes; 16 bit incl. sign
— Input resistance (Pt 200)1 MΩ
● Pt 500Yes; 16 bit incl. sign
— Input resistance (Pt 500)1 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohmsYes; 15 bit
— Input resistance (0 to 150 ohms)1 MΩ
● 0 to 300 ohmsYes; 15 bit
— Input resistance (0 to 300 ohms)1 MΩ
● 0 to 600 ohmsYes; 15 bit
— Input resistance (0 to 600 ohms)1 MΩ
● 0 to 3000 ohmsYes; 15 bit
— Input resistance (0 to 3000 ohms)1 MΩ
● 0 to 6000 ohmsYes; 15 bit
— Input resistance (0 to 6000 ohms)1 MΩ
● PTCYes; 15 bit
— Input resistance (PTC)1 MΩ
Thermocouple (TC)
Temperature compensation
— parameterizableYes
— Reference channel of the moduleYes
— internal comparison pointYes; with BaseUnit type A1
— Reference channel of the groupYes
— Number of reference channel groups4; Group 0 to 3
— fixed reference temperatureYes
Cable length
● shielded, max.200 m; 50 m with thermocouples
Analog value generation for the inputs
Measurement principleintegrating (Sigma-Delta)
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.16 bit
● Integration time, parameterizableYes
● Basic conversion time, including integration time (ms)
— additional processing time for wire-break check2 ms; In the ranges resistance thermometers, resistors and thermocouples
— additional power line wire-break check2 ms; for 3/4 wire transducer (resistance thermometer and resistor)
● Interference voltage suppression for interference frequency f1 in Hz16.6 / 50 / 60 Hz
● Conversion time (per channel)180 / 60 / 50 ms
Smoothing of measured values
● Number of smoothing levels4; None; 4/8/16 times
● parameterizableYes
Encoder
Connection of signal encoders
● for voltage measurementYes
● for resistance measurement with two-wire connectionYes
● for resistance measurement with three-wire connectionYes
● for resistance measurement with four-wire connectionYes
Errors/accuracies
Linearity error (relative to input range), (+/-)0.01 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, min.50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)0.2 %
● Resistance, relative to input range, (+/-)0.2 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)0.05 %
● Resistance, relative to input range, (+/-)0.05 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min.70 dB
● Common mode voltage, max.10 V
● Common mode interference, min.90 dB
Interrupts/diagnostics/status information
Diagnostics functionYes
Alarms
● Diagnostic alarmYes
● Limit value alarmYes; two upper and two lower limit values in each case
Diagnoses
● Monitoring the supply voltageYes
● Wire-breakYes; channel by channel
● Group errorYes
● Overflow/underflowYes; channel by channel
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
● Channel status displayYes; green LED
● for channel diagnosticsYes; red LED
● for module diagnosticsYes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channelsNo
● between the channels and backplane busYes
● between the channels and the power supply of the electronicsYes
Permissible potential difference
between the inputs (UCM)10 V DC
Isolation
Isolation tested with707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
● horizontal installation, max.60 °C; = Tmax
● vertical installation, min.-40 °C; = Tmin; Startup @ -25 °C
● vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m
● Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
● Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width15 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.30 g
last modified:08/29/2020


Product
Article Number (Market Facing Number)6AG1134-6JD00-2CA1
Product DescriptionSIPLUS ET 200SP, Analog input module, AI 4xRTD/TC High Feature, -40...+60°C start up -25°C with conformal coating based on 6ES7134-6JD00-0CA1. suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.1% , 2-/3-/4-wire
Product familySIPLUS analog inputs
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group473
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99H
Standard lead time ex-works37 Day/Days
Net Weight (kg)0,039 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension6,50 x 7,60 x 2,30
Package size unit of measureCM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047618043247
UPC887621207069
Commodity Code85389091
LKZ_FDB/ CatalogIDA&DSE/SIP ADD
Product Group4257
Group CodeR740
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 18.12.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

4,4'-isopropylidenediphenol (Bisphenol A, BPA)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-24-26-01
eClass7.127-24-26-01
eClass827-24-26-01
eClass927-24-26-01
eClass9.127-24-26-01
ETIM4EC001596
ETIM5EC001596
ETIM6EC001596
ETIM7EC001596
IDEA43562
UNSPSC1532-15-17-05

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.