6AG1134-6FF00-2AA1 SIEMENS SIPLUS ET 200SP AI 8xU BASIC -40 ... +60°C with conformal coating based on 6ES713.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

6AG1134-6FF00-2AA1 SIEMENS SIPLUS ET 200SP AI 8xU BASIC -40 ... +60°C with conformal coating based on 6ES713..

6AG1134-6FF00-2AA1

SIEMENS

SIPLUS ET 200SP AI 8xU BASIC -40 ... +60°C with conformal coating based on 6ES7134-6FF00-0AA1 . AI 8XU Basic, suitable for BU type A0, A1, Color code CC02, Module diagnostics, 16 bit

SIPLUS ET 200SP AI 8xU BASIC -40 ... +60 °C with coating formed based on 6ES7134-6FF00-0AA1 . AI 8XU BASIC, suitable for type BU A0, A1, color code CC02, module diagnosis, 16bit

More details


AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $748.16
Unit price: $748.16
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001596 - Fieldbus, decentr. periphery - analogue I/O module

Value Unit
Category according to EN 954-1 (EF006782) -
Explosion safety category for dust (EF003998) -
Type of electric connection (EF003961) -
Supply voltage AC 60 Hz (EF007533) -V
SIL according to IEC 61508 (EF009889) -
Explosion safety category for gas (EF003997) -
Performance level according to EN ISO 13849-1 (EF007399) -
Supply voltage AC 50 Hz (EF007532) -V
Degree of protection (IP) (EF005474) -
Degree of protection (NEMA) (EF011959) -
Supply voltage DC (EF007534) ['19.2', '28.8']V
Voltage type of supply voltage (EF002991) DC
Input, current (EF003204) false
Input, voltage (EF003205) true
Input, resistor (EF003206) false
Input, resistance thermometer (EF003207) false
Input, thermocouple (EF003208) false
Input signal, configurable (EF003209) true
Resolution of the analogue inputs (EF003575) 16Bit
Output, current (EF003212) -
Output, voltage (EF003213) -
Output signal configurable (EF003214) -
Resolution of the analogue outputs (EF003577) -Bit
Number of analogue inputs (EF001994) 8
Number of analogue outputs (EF001995) 0
Analogue inputs configurable (EF008518) true
Analogue outputs configurable (EF008519) -
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) -
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
Supporting protocol for TCP/IP (EF003050) false
Supporting protocol for PROFIBUS (EF003052) -
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET IO (EF007525) -
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) -
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) -
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
System accessory (EF004118) true
Fieldbus connection over separate bus coupler possible (EF004002) -
Rail mounting possible (EF003972) true
Wall mounting/direct mounting (EF007020) false
Front build in possible (EF007016) true
Rack-assembly possible (EF007018) true
Suitable for safety functions (EF001597) -
Appendant operation agent (Ex ia) (EF004141) -
Appendant operation agent (Ex ib) (EF004142) -
Width (EF000008) 15.0mm
Height (EF000040) -mm
Depth (EF000049) -mm


SIPLUS ET 200SP AI 8xU BASIC -40 ... +60°C with conformal coating based on 6ES7134-6FF00-0AA1 . AI 8XU Basic, suitable for BU type A0, A1, Color code CC02, Module diagnostics, 16 bit
General information
Product type designationAI 8xU BA
Firmware version
● FW update possibleYes
usable BaseUnitsBU type A0, A1
Color code for module-specific color identification plateCC02
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeNo
● Measuring range scalableNo
Engineering with
● PROFIBUS from GSD version/GSD revisionGSD Revision 5
● PROFINET from GSD version/GSD revisionGSDML V2.3
Operating mode
● OversamplingNo
● MSINo
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNNo
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption, max.25 mA
Power loss
Power loss, typ.0.7 W
Address area
Address space per module
● Address space per module, max.16 byte
Analog inputs
Number of analog inputs8; Single-ended
permissible input voltage for voltage input (destruction limit), max.30 V
Cycle time (all channels), min.1 ms; per channel
Input ranges (rated values), voltages
● 0 to +10 VYes; 15 bit
— Input resistance (0 to 10 V)100 kΩ
● -10 V to +10 VYes; 16 bit incl. sign
— Input resistance (-10 V to +10 V)100 kΩ
Cable length
● shielded, max.200 m
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.16 bit
● Integration time, parameterizableYes
● Interference voltage suppression for interference frequency f1 in Hz16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60)
● Conversion time (per channel)180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms
Smoothing of measured values
● Number of smoothing levels4; None; 4/8/16 times
● parameterizableYes
Encoder
Connection of signal encoders
● for voltage measurementYes
● for current measurement as 4-wire transducerNo
Errors/accuracies
Linearity error (relative to input range), (+/-)0.02 %
Temperature error (relative to input range), (+/-)0.009 %/K
Crosstalk between the inputs, min.-50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)0.9 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min.70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB
Interrupts/diagnostics/status information
Diagnostics functionYes
Alarms
● Diagnostic alarmYes
● Limit value alarmNo
Diagnoses
● Monitoring the supply voltageYes
● Wire-breakNo
● Short-circuitNo
● Group errorYes
● Overflow/underflowYes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
● Channel status displayYes; green LED
● for channel diagnosticsNo
● for module diagnosticsYes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channelsNo
● between the channels and backplane busYes
● between the channels and the power supply of the electronicsNo
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
● horizontal installation, max.60 °C; = Tmax
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m
● Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
● Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width15 mm
Weights
Weight, approx.31 g
last modified:08/29/2020


Product
Article Number (Market Facing Number)6AG1134-6FF00-2AA1
Product DescriptionSIPLUS ET 200SP AI 8xU BASIC -40 ... +60°C with conformal coating based on 6ES7134-6FF00-0AA1 . AI 8XU Basic, suitable for BU type A0, A1, Color code CC02, Module diagnostics, 16 bit
Product familySIPLUS analog inputs
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group473
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works37 Day/Days
Net Weight (kg)0,039 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension7,70 x 7,00 x 2,50
Package size unit of measureCM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047618074906
UPC804766352942
Commodity Code85389091
LKZ_FDB/ CatalogIDA&DSE/SIP ADD
Product Group4257
Group CodeR740
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.06.2016
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-24-26-01
eClass7.127-24-26-01
eClass827-24-26-01
eClass927-24-26-01
eClass9.127-24-26-01
ETIM5EC001596
ETIM6EC001596
ETIM7EC001596
IDEA43562
UNSPSC1532-15-17-05

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.