| SIPLUS SIMOCODE pro V basic unit 2 based on 3UF7010-1AU00-0 with conformal coating, -25…+60 °C, PROFIBUS DP interface 12 Mbps, RS-485; 4 I/3 O freely parameterizable US: 110-240 V AC/DC; input for thermistor connection; monostable relay outputs; expandable by expansion modules |
| product brand name | SIPLUS |
| product designation | Motor management system |
| design of the product | basic unit 2 |
| product type designation | SIMOCODE pro V |
| General technical data |
| product function | |
| ● bus communication | Yes |
| ● data acquisition function | Yes |
| ● diagnostics function | Yes |
| ● password protection | Yes |
| ● test function | Yes |
| ● maintenance function | Yes |
| product component | |
| ● input for thermistor connection | Yes |
| ● digital input | Yes |
| ● input for analog temperature sensors | No |
| ● input for ground fault detection | No |
| ● relay output | Yes |
| product extension | |
| ● temperature monitoring module | Yes |
| ● current measuring module | Yes |
| ● current/voltage measuring module | Yes |
| ● fail-safe digital I/O module | Yes |
| ● ground-fault monitoring module | Yes |
| ● control unit with display | Yes |
| ● control unit | Yes |
| ● analog I/O module | Yes |
| insulation voltage with degree of pollution 3 at AC rated value | 300 V |
| surge voltage resistance rated value | 4 000 V |
| protection class IP | IP20 |
| shock resistance | |
| ● according to IEC 60068-2-27 | 15g / 11 ms |
| |
| ● vibration resistance | 1-6 Hz / 15 mm; 6-500 Hz / 2 g |
| switching capacity current of the NO contacts of the relay outputs at AC-15 | |
| ● at 24 V | 6 A |
| ● at 120 V | 6 A |
| ● at 230 V | 3 A |
| switching capacity current of the NO contacts of the relay outputs at DC-13 | |
| ● at 24 V | 2 A |
| ● at 60 V | 0.55 A |
| ● at 125 V | 0.25 A |
| mechanical service life (switching cycles) typical | 10 000 000 |
| electrical endurance (switching cycles) typical | 100 000 |
| buffering time in the event of power failure | 0.2 s |
| reference code according to IEC 81346-2 | F |
| continuous current of the NO contacts of the relay outputs | |
| ● at 50 °C | 6 A |
| ● at 60 °C | 5 A |
| type of input characteristic | Type 1 in accordance with EN 61131-2 |
| Substance Prohibitance (Date) | 05/01/2012 |
| Electromagnetic compatibility |
| EMC emitted interference according to IEC 60947-1 | class A |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| conducted interference | |
| ● due to burst according to IEC 61000-4-4 | 2 kV (power ports) / 1 kV (signal ports) |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| ● due to high-frequency radiation according to IEC 61000-4-6 | 10 V |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| conducted HF interference emissions according to CISPR11 | corresponds to degree of severity A |
| field-bound HF interference emission according to CISPR11 | corresponds to degree of severity A |
| Inputs/ Outputs |
| product function | |
| ● parameterizable inputs | Yes |
| ● parameterizable outputs | Yes |
| number of inputs | 4 |
| ● for thermistor connection | 1 |
| number of digital inputs with a common reference potential | 4 |
| digital input version type 1 acc. to IEC 61131 | Yes |
| input voltage at digital input at DC rated value | 24 V |
| number of outputs | 3 |
| number of semiconductor outputs | 0 |
| number of outputs as contact-affected switching element | 3 |
| switching behavior | monostable |
| wire length for digital signals maximum | 300 m |
| wire length for thermistor connection | |
| ● with conductor cross-section = 0.5 mm² maximum | 50 m |
| ● with conductor cross-section = 1.5 mm² maximum | 150 m |
| ● with conductor cross-section = 2.5 mm² maximum | 250 m |
| Protective and monitoring functions |
| product function | |
| ● asymmetry detection | Yes |
| ● blocking current evaluation | Yes |
| ● power factor monitoring | Yes |
| ● ground fault detection | Yes |
| ● phase failure detection | Yes |
| ● phase sequence recognition | Yes |
| ● voltage detection | Yes |
| ● monitoring of number of start operations | Yes |
| ● overvoltage detection | Yes |
| ● overcurrent detection 1 phase | Yes |
| ● undervoltage detection | Yes |
| ● undercurrent detection 1 phase | Yes |
| ● active power monitoring | Yes |
| product function | |
| ● current detection | Yes |
| ● overload protection | Yes |
| ● evaluation of thermistor motor protection | Yes |
| response value of thermoresistor | 3 400 ... 3 800 Ω |
| release value of thermoresistor | 1 500 ... 1 650 Ω |
| Motor control functions |
| product function | |
| ● parameterizable overload relay | Yes |
| ● circuit breaker control | Yes |
| ● direct start | Yes |
| ● reverse starting | Yes |
| ● star-delta circuit | Yes |
| ● star-delta reversing circuit | Yes |
| ● Dahlander circuit | Yes |
| ● Dahlander reversing circuit | Yes |
| ● pole-changing switch circuit | Yes |
| ● pole-changing switch reversing circuit | Yes |
| ● slide control | Yes |
| ● valve control | Yes |
| Communication/ Protocol |
| |
| ● protocol is supported PROFIBUS DP protocol | Yes |
| ● protocol is supported PROFINET IO protocol | No |
| ● protocol is supported PROFIsafe protocol | Yes |
| ● protocol is supported Modbus RTU | No |
| ● protocol is supported EtherNet/IP | No |
| ● protocol is supported OPC UA Server | No |
| ● protocol is supported LLDP | No |
| ● protocol is supported Address Resolution Protocol (ARP) | No |
| ● protocol is supported SNMP | No |
| ● protocol is supported HTTPS | No |
| ● protocol is supported NTP | No |
| ● protocol is supported Media Redundancy Protocol (MRP) | No |
| ● product function is supported Device Level Ring (DLR) | No |
| number of interfaces | |
| ● according to PROFIBUS | 1 |
| product function | |
| ● web server | No |
| ● shared device | No |
| ● at the Ethernet interface Autocrossover | No |
| ● at the Ethernet interface Autonegotiation | No |
| ● at the Ethernet interface Autosensing | No |
| ● is supported PROFINET system redundancy | No |
| ● supports PROFIenergy measured values | No |
| ● supports PROFIenergy shutdown | No |
| transfer rate maximum | 12 Mbit/s |
| identification & maintenance function | |
| ● I&M0 - device-specific information | Yes |
| ● I&M1 – higher level designation/location designation | Yes |
| ● I&M2 - installation date | Yes |
| ● I&M3 - comment | Yes |
| type of electrical connection of the communication interface | 9-pin SUB-D socket (12 Mbit) / screw terminal (1.5 Mbit) |
| Installation/ mounting/ dimensions |
| mounting position | any |
| fastening method | screw and snap-on mounting |
| height | 111 mm |
| width | 45 mm |
| depth | 124 mm |
| Connections/ Terminals |
| product component removable terminal for auxiliary and control circuit | Yes |
| type of connectable conductor cross-sections | |
| ● solid | 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) |
| ● finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| ● at AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
| ● at AWG cables stranded | 1x (20 ... 14), 2x (20 ... 16) |
| tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
| tightening torque [lbf·in] with screw-type terminals | 7 ... 10.3 lbf·in |
| type of connectable conductor cross-sections for PROFIBUS wire | 2x 0.34 mm², AWG 22 |
| Ambient conditions |
| installation altitude at height above sea level | |
| ● 1 maximum | 2 000 m |
| ● 2 maximum | 3 000 m |
| ● 3 maximum | 4 000 m; max. +40 °C (no protective separation) |
| ambient temperature | |
| ● during operation | -25 ... +60 °C |
| ● during storage | -40 ... +80 °C |
| ● during transport | -40 ... +80 °C |
| relative humidity | |
| ● with condensation maximum | 100 %; RH incl. condensation/frost (no commissioning in bedewed state) |
| ambient condition relating to ambient temperature - air pressure - installation altitude | -25 ... +60°C at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // -25 ... +50°C at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // -25 ... +40°C at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
| resistance to mechanically active substances conformity according to EN 60721-3-3 | Yes; The supplied plug covers must remain in place over the unused interfaces during operation! |
| resistance to chemically active substances conformity according to EN 60721-3-3 | Yes; Compliant with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna); the supplied plug covers must remain in place on the unused interfaces during operation. |
| resistance to biologically active substances conformity according to EN 60721-3-3 | Yes; Compliant with EN 60721-3-3, Class 3C4 incl. salt spray in accordance with EN 60068-2-52 (severity 3); the supplied plug covers must remain in place on the unused interfaces during operation. |
| resistance to salt-laden atmosphere conformity according to EN 60068-2-52 | Yes; Severity 3 |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| Short-circuit protection |
| design of short-circuit protection per output | Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) |
| Safety related data |
| touch protection against electrical shock | finger-safe |
| Main circuit |
| operating voltage | |
| ● at AC | |
| — at 50 Hz rated value | 110 ... 240 V |
| — at 60 Hz rated value | 110 ... 240 V |
| ● at DC rated value | 110 ... 240 V |
| Control circuit/ Control |
| product function soft starter control | Yes |
| type of voltage of the control supply voltage | AC/DC |
| control supply voltage at AC | |
| ● at 50 Hz rated value | 110 ... 240 V |
| ● at 60 Hz rated value | 110 ... 240 V |
| control supply voltage frequency | |
| ● 1 rated value | 50 Hz |
| ● 2 rated value | 60 Hz |
| control supply voltage at DC | |
| ● rated value | 110 ... 240 V |
| control supply voltage 1 at DC rated value | 240 V |
| operating range factor control supply voltage rated value at DC | |
| ● initial value | 0.85 |
| ● full-scale value | 1.1 |
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| ● initial value | 0.85 |
| ● full-scale value | 1.1 |
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| ● initial value | 0.85 |
| ● full-scale value | 1.1 |
Downloads and manuals |
| Certificates/ approvals |
| Further information |
Information- and Downloadcenter (Catalogs, Brochures,…) |
Industry Mall (Online ordering system) |
Cax online generator |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) |
Test report No. A0258, protective separation |
|
|
|
| last modified: | 1/27/2022 |
Date 5/6/2022 | Subject to change without notice © Copyright Siemens 2022 |