ANUNCIAR
3SK1122-2AB40 SIEMENS SIRIUS safety relay Basic unit Advanced series 3 electronic enabling circuits 1 electr.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3SK1122-2AB40 SIEMENS SIRIUS safety relay Basic unit Advanced series 3 electronic enabling circuits 1 electr..

3SK1122-2AB40

SIEMENS

SIRIUS safety relay Basic unit Advanced series 3 electronic enabling circuits 1 electronic signaling circuit Us = 24 V DC Spring-type terminal (push-in)

SIRIUS Safety Relay; Advanced Base Unit; 3 NA elect. + 1 NC; 24 V DC; Push-In connection.

More details


Relays > Device for monitoring of safety-related circuits

CONTROL AND CONTACTORS > Limit Switches and safety relays

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $227.84
Unit price: $227.84
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

SIRIUS safety relay Basic unit Advanced series 3 electronic enabling circuits 1 electronic signaling circuit Us = 24 V DC Spring-type terminal (push-in)
product brand nameSIRIUS
product categorySafety relays
product designationsafety relays
design of the productSolid-state enabling circuits
General technical data
protection class IP of the enclosureIP20
touch protection against electrical shockfinger-safe
insulation voltage rated value50 V
ambient temperature
● during storage-40 ... +80 °C
● during operation-25 ... +60 °C
air pressure according to SN 31205900 ... 1 060 hPa
relative humidity during operation10 ... 95 %
installation altitude at height above sea level maximum2 000 m
vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0.75 mm
shock resistance10g / 11 ms
surge voltage resistance rated value800 V
EMC emitted interferenceIEC 60947-5-1, Class A
installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
overvoltage category3
degree of pollution3
reference code according to IEC 81346-2F
power loss [W] maximum2 W
number of sensor inputs 1-channel or 2-channel1
design of the cascadingyes
type of the safety-related wiring of the inputssingle-channel and two-channel
product feature cross-circuit-proofYes
Safety Integrity Level (SIL)
● according to IEC 620613
● according to IEC 615083
performance level (PL)
● according to ISO 13849-1e
category according to EN ISO 13849-14
Safe failure fraction (SFF)99 %
PFHD with high demand rate according to EN 620610.0000000013 1/h
PFDavg with low demand rate according to IEC 615080.000007
T1 value for proof test interval or service life according to IEC 6150820 y
hardware fault tolerance according to IEC 615081
safety device type according to IEC 61508-2Type B
Inputs/ Outputs
number of outputs as contact-affected switching element
● as NO contact
— safety-related instantaneous contact0
— safety-related delayed switching0
number of outputs as contact-less semiconductor switching element
● safety-related
— instantaneous contact3
● for signaling function instantaneous contact1
stop category according to EN 60204-10
design of input
● cascading input/functional switchingYes
● feedback inputYes
● start inputYes
type of electrical connection plug-in socketNo
operating frequency maximum2 000 1/h
switching capacity current
● of semiconductor outputs at DC-13 at 24 V2 A
design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requirednot required
wire length
● with Cu 1.5 mm² and 150 nF/km per sensor circuit maximum4 000 m
make time with automatic start
● at DC maximum85 ms
make time with automatic start after power failure
● typical6 500 ms
● maximum6 500 ms
make time with monitored start
● maximum85 ms
backslide delay time after opening of the safety circuits typical40 ms
recovery time after opening of the safety circuits typical30 ms
recovery time after power failure typical6.5 s
pulse duration
● of the sensor input minimum60 ms
● of the ON pushbutton input minimum0.15 s
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage
● at DC
— rated value24 V
operating range factor control supply voltage rated value of magnet coil
● at DC0.8 ... 1.2
Installation/ mounting/ dimensions
mounting positionany
required spacing for grounded parts at the side5 mm
fastening methodscrew and snap-on mounting
width22.5 mm
height100 mm
depth121.6 mm
Connections/ Terminals
type of electrical connectionspring-loaded terminal (push-in)
type of connectable conductor cross-sections
● solid1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
● finely stranded
— with core end processing1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²)
— without core end processing1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections at AWG cables
● solid1x (20 ... 16), 2x (20 ... 16)
● stranded1x (20 ... 16), 2x (20 ... 16)
Product Function
product function parameterizablesensor floating / sensor non-floating, monitored start-up / automatic start, 1-channel / 2-channel sensor connection, cross-circuit detection, startup testing, antivalent sensors, 2-hand switches
suitability for operation device connector 3ZY12Yes
suitability for interaction press controlYes
suitability for use
● safety switchYes
● monitoring of floating sensorsYes
● monitoring of non-floating sensorsYes
● magnetically operated switch monitoringYes
● safety-related circuitsYes
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMC

CSA

Confirmation

CCC

UL

EAC

RCM

Functional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / Shipping

Type Examination Certificate

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

DNV / Det Norske Veritas

LR (Lloyds Register)

RINA / Registro Italiano Navale

Marine / ShippingotherRailway

RMRS / Russian Maritime Register

Confirmation

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:3/29/2022
Date
5/7/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3SK1122-2AB40
Product DescriptionSIRIUS safety relay Basic unit Advanced series 3 electronic enabling circuits 1 electronic signaling circuit Us = 24 V DC Spring-type terminal (push-in)
Product familySIRIUS 3SK1 Advanced basic units
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41L / 41L
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works180 Day/Days
Net Weight (kg)0,199 Kg
Packaging Dimension36,00 x 109,00 x 152,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209913707
UPC887621548995
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group3761
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 05.11.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead titanium zirconium oxide

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-18-19
eClass7.127-37-18-19
eClass827-37-18-19
eClass927-37-18-19
eClass9.127-37-18-19
ETIM5EC001449
ETIM6EC001449
ETIM7EC001449
ETIM8EC001449
IDEA45166
UNSPSC1539-12-22-05

ETIM data

ETIM: EC001449 - Device for monitoring of safety-related circuits

Value Unit
Model (EF000010) -
Suitable for monitoring of position switches (EF007270) true
Suitable for monitoring of emergency-stop circuits (EF007268) true
Suitable for monitoring of valves (EF007272) -
Suitable for monitoring of optoelectronic protection equipment (EF007269) true
Suitable for monitoring of tactile sensors (EF007271) -
Suitable for monitoring of magnetic switches (EF007266) true
Suitable for monitoring of proximity switches (EF007267) -
Type of electric connection (EF003961) Spring clamp connection
Rail mounting possible (EF003972) FALSE
Rated control supply voltage Us at DC (EF003980) ['-', '24']V
Voltage type for actuating (EF008242) DC
With detachable clamps (EF003340) false
Evaluation inputs (EF008245) One- and two-channel
With start input (EF003342) true
With muting function (EF004057) false
With feedback circuit (EF003343) true
Number of outputs, safety related, undelayed, semiconductors (EF003346) 3
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 1
Number of outputs, signalling function, delayed, semiconductors (EF003351) -
Category according to EN 954-1 (EF006782) -
Type of safety according to IEC 61496-1 (EF004105) -
Stop category according to IEC 60204 (EF007498) 0
Performance level according to EN ISO 13849-1 (EF007399) Level e
SIL according to IEC 61508 (EF009889) 3
With approval for TÜV (EF004144) true
With approval for BG BIA (EF004145) -
With approval according to UL (EF001783) true
Width (EF000008) 22.5mm
Height (EF000040) 100.0mm
Depth (EF000049) 121.6mm
Release-delay (EF001129) -s
Number of outputs, safety related, undelayed, with contact (EF003344) -
Number of outputs, safety related, delayed, with contact (EF003345) -
Number of outputs, signalling function, undelayed, with contact (EF003348) -
Number of outputs, signalling function, delayed, with contact (EF003349) -
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Rated control supply voltage Us at AC 60HZ (EF003979) -V



Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.