ANUNCIAR
3RW5534-2HF04 SIEMENS SIRIUS soft starter 200-480 V 113 A, 24 V AC/DC spring-type terminals Fail-safe View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RW5534-2HF04 SIEMENS SIRIUS soft starter 200-480 V 113 A, 24 V AC/DC spring-type terminals Fail-safe

3RW5534-2HF04

SIEMENS

SIRIUS soft starter 200-480 V 113 A, 24 V AC/DC spring-type terminals Fail-safe

Soft starters SIRIUS 200-480 V 113 A, 24 V AC/DC safety spring terminals

More details


CONTROL AND CONTACTORS > Soft starters for high-feature applications

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $3,355.10
Unit price: $3,355.10
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SIRIUS soft starter 200-480 V 113 A, 24 V AC/DC spring-type terminals Fail-safe
product brand nameSIRIUS
product categoryHybrid switching devices
product designationFailsafe soft starters
product type designation3RW55
manufacturer's article number
● of high feature HMI module usable3RW5980-0HF00
● of communication module PROFINET standard usable3RW5980-0CS00
● of communication module PROFINET high-feature usable3RW5950-0CH00
● of communication module PROFIBUS usable3RW5980-0CP00
● of communication module Modbus TCP usable3RW5980-0CT00
● of communication module Modbus RTU usable3RW5980-0CR00
● of communication module Ethernet/IP3RW5980-0CE00
● of circuit breaker usable at 400 V3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 400 V at inside-delta circuit3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
● of the gG fuse usable up to 690 V3NA3244-6; Type of coordination 1, Iq = 65 kA
● of the gG fuse usable at inside-delta circuit up to 500 V3NA3244-6; Type of coordination 1, Iq = 65 kA
● of full range R fuse link for semiconductor protection usable up to 690 V3NE1225-0; Type of coordination 2, Iq = 65 kA
● of back-up R fuse link for semiconductor protection usable up to 690 V3NE3231; Type of coordination 2, Iq = 65 kA
General technical data
starting voltage [%]20 ... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0 ... 360 s
ramp-down time of soft starter0 ... 360 s
start torque [%]10 ... 100 %
stopping torque [%]10 ... 100 %
torque limitation [%]20 ... 200 %
current limiting value [%] adjustable125 ... 800 %
breakaway voltage [%] adjustable40 ... 100 %
breakaway time adjustable0 ... 2 s
number of parameter sets3
accuracy class according to IEC 61557-125 %
certificate of suitability
● CE markingYes
● UL approvalYes
● CSA approvalYes
product component
● HMI-High FeatureYes
● is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases3
trip classCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
current unbalance limiting value [%]10 ... 60 %
ground-fault monitoring limiting value [%]10 ... 95 %
buffering time in the event of power failure
● for main current circuit100 ms
● for control circuit100 ms
idle time adjustable0 ... 255 s
insulation voltage rated value480 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 400 V
service factor1.15
surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
● between main and auxiliary circuit480 V; does not apply for thermistor connection
shock resistance15 g / 11 ms, from 6 g / 11 ms with potential contact lifting
vibration resistance15 mm up to 6 Hz; 2 g up to 500 Hz
recovery time after overload trip adjustable60 ... 1 800 s
utilization category according to IEC 60947-4-2AC 53a
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)11/22/2019
product function
● ramp-up (soft starting)Yes
● ramp-down (soft stop)Yes
● breakaway pulseYes
● adjustable current limitationYes
● creep speed in both directions of rotationYes
● pump ramp downYes
● DC brakingYes
● motor heatingYes
● slave pointer functionYes
● trace functionYes
● intrinsic device protectionYes
● motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
● evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
● inside-delta circuitYes
● auto-RESETYes
● manual RESETYes
● remote resetYes
● communication functionYes
● operating measured value displayYes
● event listYes
● error logbookYes
● via software parameterizableYes
● via software configurableYes
● screw terminalNo
● spring-loaded terminalYes
● PROFIenergyYes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules
● firmware updateYes
● removable terminal for control circuitYes
● voltage rampYes
● torque controlYes
● combined brakingYes
● analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
● programmable control inputs/outputsYes
● condition monitoringYes
● automatic parameterisationYes
● application wizardsYes
● alternative run-downYes
● emergency operation modeYes
● reversing operationYes
● soft starting at heavy starting conditionsYes
Power Electronics
operational current
● at 40 °C rated value113 A
● at 40 °C rated value minimum23 A
● at 50 °C rated value101 A
● at 60 °C rated value89 A
operational current at inside-delta circuit
● at 40 °C rated value196 A
● at 50 °C rated value175 A
● at 60 °C rated value154 A
operating voltage
● rated value200 ... 480 V
● at inside-delta circuit rated value200 ... 480 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at inside-delta circuit-15 %
relative positive tolerance of the operating voltage at inside-delta circuit10 %
operating power for 3-phase motors
● at 230 V at 40 °C rated value30 kW
● at 230 V at inside-delta circuit at 40 °C rated value55 kW
● at 400 V at 40 °C rated value55 kW
● at 400 V at inside-delta circuit at 40 °C rated value110 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
minimum load [%]10 %; Relative to set Ie
power loss [W] for rated value of the current at AC
● at 40 °C after startup34 W
● at 50 °C after startup30 W
● at 60 °C after startup27 W
power loss [W] at AC at current limitation 350 %
● at 40 °C during startup1 500 W
● at 50 °C during startup1 279 W
● at 60 °C during startup1 074 W
type of the motor protectionElectronic, tripping in the event of thermal overload of the motor
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage at AC
● at 50 Hz rated value24 V
● at 60 Hz rated value24 V
relative negative tolerance of the control supply voltage at AC at 50 Hz-20 %
relative positive tolerance of the control supply voltage at AC at 50 Hz20 %
relative negative tolerance of the control supply voltage at AC at 60 Hz-20 %
relative positive tolerance of the control supply voltage at AC at 60 Hz20 %
control supply voltage frequency50 ... 60 Hz
relative negative tolerance of the control supply voltage frequency-10 %
relative positive tolerance of the control supply voltage frequency10 %
control supply voltage
● at DC rated value24 V
relative negative tolerance of the control supply voltage at DC-20 %
relative positive tolerance of the control supply voltage at DC20 %
control supply current in standby mode rated value440 mA
holding current in bypass operation rated value870 mA
locked-rotor current at close of bypass contact maximum6.3 A
inrush current peak at application of control supply voltage maximum7.5 A
duration of inrush current peak at application of control supply voltage20 ms
design of the overvoltage protectionVaristor
design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Inputs/ Outputs
number of digital inputs4
● with fail-safe1
● parameterizable4
● number of digital outputs3
● Number of digital outputs with fail-safe1
● number of digital outputs parameterizable2
● number of digital outputs not parameterizable1
digital output version2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover contact (CO)
number of analog outputs1
switching capacity current of the relay outputs
● at AC-15 at 250 V rated value3 A
● at DC-13 at 24 V rated value1 A
Installation/ mounting/ dimensions
mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
fastening methodscrew fixing
height306 mm
width185 mm
depth203 mm
required spacing with side-by-side mounting
● forwards10 mm
● backwards0 mm
● upwards100 mm
● downwards75 mm
● at the side5 mm
weight without packaging6.85 kg
Connections/ Terminals
type of electrical connection
● for main current circuitbusbar connection
● for control circuitspring-loaded terminals
width of connection bar maximum25 mm
wire length for thermistor connection
● with conductor cross-section = 0.5 mm² maximum50 m
● with conductor cross-section = 1.5 mm² maximum150 m
● with conductor cross-section = 2.5 mm² maximum250 m
type of connectable conductor cross-sections
● for DIN cable lug for main contacts stranded2x (16 ... 95 mm²)
● for DIN cable lug for main contacts finely stranded2x (25 ... 120 mm²)
type of connectable conductor cross-sections
● for control circuit solid2x (0.25 ... 1.5 mm²)
● for control circuit finely stranded with core end processing2x (0.25 ... 1.5 mm²)
● at AWG cables for control circuit solid2x (24 ... 16)
● at AWG cables for control circuit finely stranded with core end processing2x (24 ... 16)
wire length
● between soft starter and motor maximum800 m
● at the digital inputs at DC maximum1 000 m
tightening torque
● for main contacts with screw-type terminals10 ... 14 N·m
● for auxiliary and control contacts with screw-type terminals0.8 ... 1.2 N·m
tightening torque [lbf·in]
● for main contacts with screw-type terminals89 ... 124 lbf·in
● for auxiliary and control contacts with screw-type terminals7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum2 000 m; Derating as of 1000 m, see catalog
ambient temperature
● during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
● during storage and transport-40 ... +80 °C
environmental category
● during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
● during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
Communication/ Protocol
communication module is supported
● PROFINET standardYes
● PROFINET high-featureYes
● EtherNet/IPYes
● Modbus RTUYes
● Modbus TCPYes
● PROFIBUSYes
UL/CSA ratings
manufacturer's article number
● of circuit breaker
— usable for Standard Faults at 460/480 V according to ULSiemens type: 3VA52, max. 250 A; Iq = 10 kA
— usable for High Faults at 460/480 V according to ULSiemens type: 3VA52, max. 250 A; Iq max = 65 kA
— usable for Standard Faults at 460/480 V at inside-delta circuit according to ULSiemens type: 3VA52, max. 250 A; Iq = 10 kA
— usable for High Faults at 460/480 V at inside-delta circuit according to ULSiemens type: 3VA52, max. 250 A; Iq max = 65 kA
— usable for Standard Faults at 575/600 V according to ULSiemens type: 3VA52, max. 250 A; Iq = 10 kA
— usable for High Faults at 575/600 V at inside-delta circuit according to ULSiemens type: 3VA52, max. 250 A; Iq max = 65 kA
— usable for Standard Faults at 575/600 V at inside-delta circuit according to ULSiemens type: 3VA52, max. 250 A; Iq = 10 kA
● of the fuse
— usable for Standard Faults up to 575/600 V according to ULType: Class RK5 / K5, max. 350 A; Iq = 10 kA
— usable for High Faults up to 575/600 V according to ULType: Class J / L, max. 350 A; Iq = 100 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class RK5 / K5, max. 350 A; Iq = 10 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 350 A; Iq = 100 kA
operating power [hp] for 3-phase motors
● at 200/208 V at 50 °C rated value30 hp
● at 220/230 V at 50 °C rated value30 hp
● at 460/480 V at 50 °C rated value75 hp
● at 200/208 V at inside-delta circuit at 50 °C rated value50 hp
● at 220/230 V at inside-delta circuit at 50 °C rated value60 hp
● at 460/480 V at inside-delta circuit at 50 °C rated value125 hp
contact rating of auxiliary contacts according to ULR300-B300
Safety related data
safety type according to IEC 61496-1Type 2
safety device type according to IEC 61508-2Type B
B10 value at AC-53a500 000
B10d value500 000
Safety Integrity Level (SIL)
● according to IEC 61508SIL1
SIL Claim Limit (subsystem) according to EN 62061SIL 1
performance level (PL) according to EN ISO 13849-1c
category according to EN ISO 13849-12
stop category according to EN 60204-10
Safe failure fraction (SFF)60 %
average diagnostic coverage level (DCavg)90 %
diagnostics test interval by internal test function maximum1 000 s
PFHD with high demand rate according to EN 620610.000001 1/h
PFDavg with low demand rate according to IEC 615080.09
MTTFd30 y
hardware fault tolerance according to IEC 615080
safe stateOpen load circuit
protection class IP on the front according to IEC 60529IP00; IP20 with cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
electromagnetic compatibilityacc. to IEC 60947-4-2
ATEX
certificate of suitability
● ATEXYes
● IECExYes
● according to ATEX directive 2014/34/EUBVS 18 ATEX F 003 X
type of protection according to ATEX directive 2014/34/EUII (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb],II (2)D [Ex tb Db] [Ex pxb Db],I (M2) [Ex db Mb]
hardware fault tolerance according to IEC 61508 relating to ATEX0
PFDavg with low demand rate according to IEC 61508 relating to ATEX0.008
PFHD with high demand rate according to EN 62061 relating to ATEX0.0000005 1/h
Safety Integrity Level (SIL) according to IEC 61508 relating to ATEXSIL1
T1 value for proof test interval or service life according to IEC 61508 relating to ATEX3 s
Certificates/ approvals

Downloads and manuals

General Product Approval

CSA

CCC

Confirmation

TUEV

UL

EAC

EMCFor use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / Shipping

RCM

ATEX-EC-Type-Examination-Certificate

IECEx

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

ABS (American Bureau of Shipping)

Marine / Shippingother

BV / Bureau Veritas

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

DNV-GL

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Characteristic: Installation altitude
Simulation Tool for Soft Starters (STS)
last modified:4/10/2022
Date
5/7/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RW5534-2HF04
Product DescriptionSIRIUS soft starter 200-480 V 113 A, 24 V AC/DC spring-type terminals Fail-safe
Product family3RW55 Failsafe soft starters
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group42S / 42S
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works100 Day/Days
Net Weight (kg)10,000 Kg
Packaging Dimension303,00 x 393,00 x 333,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047621040523
UPC195125037816
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group4982
Group CodeR711
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 22.11.2019
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™)covering any of its individual anti- and syn-isomers or any combination thereof

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Dicyclohexyl phthalate (DCHP)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Dibutylbis(pentane-2,4-dionato-O,O')tin

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-07
eClass7.127-37-09-07
eClass827-37-09-07
eClass927-37-09-07
eClass9.127-37-09-07
ETIM5EC000640
ETIM6EC000640
ETIM7EC000640
ETIM8EC000640
IDEA44740
UNSPSC1539-12-15-21

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.