| Direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 0.09 kW / 400 V; Adjustment range 0.1 .. 0.4 A; PROFIenergy; Option: 3DI/LC module |
| product brand name | SIMATIC |
| product category | Motor starter |
| product designation | Direct-on-line starter |
| product type designation | ET 200SP |
| General technical data |
| trip class | CLASS OFF / 5 / 10 adjustable |
| equipment variant according to IEC 60947-4-2 | 3 |
| product function | Direct-on-line starter |
| ● on-site operation | Yes |
| ● intrinsic device protection | Yes |
| ● remote firmware update | Yes |
| ● for power supply reverse polarity protection | Yes |
| insulation voltage rated value | 500 V |
| degree of pollution | 2 |
| overvoltage category | III |
| surge voltage resistance rated value | 6 kV |
| maximum permissible voltage for safe isolation | |
| ● between main and auxiliary circuit | 500 V |
| shock resistance | 6g / 11 ms |
| vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
| operating frequency maximum | 1 1/s |
| mechanical service life (switching cycles) of the main contacts typical | 30 000 000 |
| type of assignment | 1 |
| reference code according to IEC 81346-2 | Q |
| Substance Prohibitance (Date) | 04/15/2016 |
| product function | |
| ● direct start | Yes |
| ● reverse starting | No |
| product component motor brake output | No |
| product function short circuit protection | Yes |
| design of short-circuit protection | fuse |
| breaking capacity maximum short-circuit current (Icu) | |
| ● at 400 V rated value | 55 kA |
| ● at 500 V rated value | 55 kA |
| ● at 500 V according to UL 60947 rated value | 100 kA |
| breaking capacity maximum short-circuit current (Icu) in the IT network | |
| ● at 400 V rated value | 55 kA |
| ● at 500 V rated value | 55 kA |
| Electromagnetic compatibility |
| EMC emitted interference according to IEC 60947-1 | class A |
| EMC immunity according to IEC 60947-1 | Class A |
| conducted interference | |
| ● due to burst according to IEC 61000-4-4 | 2 kV |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| ● due to high-frequency radiation according to IEC 61000-4-6 | Class A |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 8 kV air discharge |
| conducted HF interference emissions according to CISPR11 | Class A for industrial environment |
| field-bound HF interference emission according to CISPR11 | Class A for industrial environment |
| Safety related data |
| MTBF | 48 y |
| safe state | Load circuit open |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe |
| Main circuit |
| number of poles for main current circuit | 3 |
| design of the switching contact | Hybrid |
| adjustable current response value current of the current-dependent overload release | 0.1 ... 0.4 A |
| minimum load [%] | 50 %; from smallest adjustable rated current |
| type of the motor protection | solid-state |
| operating voltage rated value | 48 ... 500 V |
| relative symmetrical tolerance of the operating voltage | 10 % |
| operating frequency 1 rated value | 50 Hz |
| operating frequency 2 rated value | 60 Hz |
| relative symmetrical tolerance of the operating frequency | 5 % |
| relative positive tolerance of the operating frequency | 5 % |
| relative negative tolerance of the operating frequency | 5 % |
| operational current at AC at 400 V rated value | 0.4 A |
| ampacity when starting maximum | 4 A |
| operating power for 3-phase motors at 400 V at 50 Hz | 0.06 ... 0.12 kW |
| Inputs/ Outputs |
| number of digital inputs | 4 |
| ● note | 4 via 3DI/LC module |
| Supply voltage |
| type of voltage of the supply voltage | DC |
| supply voltage 1 at DC rated value | |
| ● minimum permissible | 20.4 V |
| ● maximum permissible | 28.8 V |
| supply voltage at DC rated value | 24 V |
| consumed current for rated value of supply voltage | |
| ● in standby mode of operation | 85 mA |
| ● during operation | 140 mA |
| ● at switching on of motor | 230 mA |
| power loss [W] for rated value of supply voltage | |
| ● in switching state OFF with bypass circuit | 2 W |
| ● in switching state ON with bypass circuit | 3.4 W |
| inrush current peak at 24 V | 25 A; Observe the manual for group configuration |
| duration of inrush current peak at 24 V | 0.145 ms |
| Response times |
| ON-delay time | 20 ms |
| OFF-delay time | 35 ... 50 ms |
| Power Electronics |
| operational current | |
| ● at 40 °C rated value | 0.4 A |
| ● at 50 °C rated value | 0.4 A |
| ● at 55 °C rated value | 0.4 A |
| ● at 60 °C rated value | 0.4 A |
| Installation/ mounting/ dimensions |
| mounting position | Vertical, horizontal (observe derating) |
| fastening method | pluggable in BaseUnit |
| height | 142 mm |
| width | 30 mm |
| depth | 150 mm |
| required spacing with side-by-side mounting | |
| ● upwards | 50 mm |
| ● downwards | 50 mm |
| Ambient conditions |
| installation altitude at height above sea level maximum | 4 000 m; For derating see manual |
| ambient temperature | |
| ● during operation | -25 ... +60 °C; For derating see manual |
| ● during storage | -40 ... +70 °C |
| ● during transport | -40 ... +70 °C |
| environmental category during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices) |
| relative humidity during operation | 10 ... 95 % |
| air pressure according to SN 31205 | 900 ... 1 060 hPa |
| Communication/ Protocol |
| protocol is supported | |
| ● PROFIBUS DP protocol | Yes |
| ● PROFINET protocol | Yes |
| product function bus communication | Yes |
| protocol is supported AS-Interface protocol | No |
| product function | |
| ● supports PROFIenergy measured values | Yes |
| ● supports PROFIenergy shutdown | Yes |
| address space memory of address range | |
| ● of the inputs | 4 byte |
| ● of the outputs | 2 byte |
| type of electrical connection of the communication interface | Plug contact to Base Unit |
| Connections/ Terminals |
| type of electrical connection | |
| ● 1 for digital input signals | Pluggable module - accessory |
| type of electrical connection | |
| ● for main energy infeed | Plug contact to Base Unit |
| ● for load-side outgoing feeder | Plug contact to Base Unit |
| ● for supply voltage line-side | Plug contact to Base Unit |
| wire length for motor unshielded maximum | 200 m |
| UL/CSA ratings |
| full-load current (FLA) for 3-phase AC motor at 480 V rated value | 0.4 A |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 480 V |
| Certificates/ approvals |
Downloads and manuals |
|
| Further information |
Information- and Downloadcenter (Catalogs, Brochures,…) |
Industry Mall (Online ordering system) |
Cax online generator |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) |
|
|
|