SENTRON, Molded case switch 3LD5 UL, Main switch, 3-pole, certified according to UL489 UL60947-4-1 and IEC60947-3, UL: 100A, SCCR 65kA at 480VAC, Operating power at 480VAC 3-phase: 60hp, IEC: 100A, Operating power at AC-23A at 400V: 45kW, floor mounting with door coupling rotary operating mechanism, defeatable, Standard, 4-hole mounting of the handle, without tolerance compensation, incl. terminal covers for the infeed side

SENTRON, 3LD5 UL switch-disconnector, main switch, 3 poles, approved according to UL 489, UL 60947-4-1 and IEC 60947-3, UL: 100 A, SCCR 65 kA at 480 V AC, operating power at 480 V AC three-phase: 60 hp, IEC: 100 A, operating power with 23 A AC at 400 V: 45 kW, fixation based on door coupling, neutralizable variant of rotary drive , standard, 4 holes fixing the lever without tolerance compensation, includes cover covers for the feed side. Cancelations and returns limited. Consult conditions.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > SWITCHES-DISCONNECTORS

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $532.15
Unit price: $532.15
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SENTRON, Molded case switch 3LD5 UL, Main switch, 3-pole, certified according to UL489 UL60947-4-1 and IEC60947-3, UL: 100A, SCCR 65kA at 480VAC, Operating power at 480VAC 3-phase: 60hp, IEC: 100A, Operating power at AC-23A at 400V: 45kW, floor mounting with door coupling rotary operating mechanism, defeatable, Standard, 4-hole mounting of the handle, without tolerance compensation, incl. terminal covers for the infeed side
Model
product brand nameSENTRON
product designation3LD UL switch disconnector
design of the productMain switch
display version / for switch position indicator manual operation1 ON - 0 OFF
design of the actuating elementdoor-coupling rotary operating mechanism
design of handlerotary operating mechanism, black
type of the driving mechanism / motor driveNo
General technical data
number of poles3
type of devicefixed mounting
type of switchFloor mounting with door coupling
size of switch disconnector3
mechanical service life (switching cycles) / typical100 000
electrical endurance (switching cycles)
● at AC-23 A / at 690 V6 000
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum223 kA2.s
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum223 kA2.s
operating frequency / maximum50 1/h
Voltage
insulation voltage / rated value690 V
surge voltage resistance / rated value6 kV
Protection class
protection class IPIP65
degree of protection NEMA rating1, 3R, 4X, 12
protection class IP / on the frontIP65
Dissipation
power loss [W]
● for rated value of the current / at AC / in hot operating state / per pole36 W
● per conductor / typical36 W
Current
operational current
● at 40 °C / rated value100 A
● at 45 °C / rated value100 A
● at 50 °C / rated value100 A
● at 55 °C / rated value100 A
● at AC / rated value100 A
● at AC-23 A / at 400 V / rated value100 A
● at AC-21 / at 690 V / rated value100 A
● at AC-21 A / at 240 V / rated value100 A
● at AC-21 A / at 440 V / rated value100 A
operational current / of upstream fuse / rated value125 A
let-through current / with closed switch
● at 440 V / for combination switch + gG fuse / maximum16 kA
● at 690 V / for combination switch + gG fuse / maximum permissible15 kA
Main circuit
operating power
● at AC-23 A / at 240 V / rated value30 kW
● at AC-23 A / at 440 V / rated value45 kW
● at AC-23 A / at 690 V / rated value37 kW
● at AC-3 / at 240 V / rated value30 kW
● at AC-3 / at 400 V / rated value45 kW
● at AC-3 / at 690 V / rated value30 kW
operational current / rated value100 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
operating voltage / of auxiliary contacts / at AC / maximum500 V
continuous current / of the auxiliary contact / rated value10 A
insulation voltage / of the auxiliary switch / rated value500 V
Suitability
suitability for use
● main switchYes
● switch disconnectorYes
● EMERGENCY OFF switchNo
● safety switchYes
● maintenance/repair switchYes
Appearance
color / of the actuating elementgray
Product details
product feature
● can be locked into OFF positionYes
number of bracket locks / maximum3
hasp thickness / of the bracket locks / minimum5 mm
hasp thickness / of the bracket locks / maximum7.5 mm
special product featuredefeatable door-coupling handle
product extension / optional
● motor driveNo
● voltage triggerNo
Short circuit
conditional short-circuit current / with line-side fuse protection
● at 440 V / by gG fuse / rated value50 kA
● at 690 V / by gG fuse / rated value50 kA
according UL
operational current / at AC / according to UL 489/UL 60947-4-1 / rated value100 A
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value100 A
operating voltage / at AC / at 50/60 Hz / according to UL 489 / rated value480 V
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value480 V
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value60
short-time withstand current (SCCR) / at 480 V / according to UL 508/UL 60947-4-1 and UL 48965 kA
continuous current / of upstream fuse / according to UL / rated value100 A
type of fuse / according to ULClass J
Number
number of connectable NC contacts / for auxiliary contacts / attachable / maximum3
number of connectable NO contacts / for auxiliary contacts / attachable / maximum5
number of connectable CO contacts / for auxiliary contacts / attachable / maximum0
Connections
AWG number / as coded connectable conductor cross section / solid
● minimum3
● maximum4/0
AWG number / as coded connectable conductor cross section / solid / according to UL 489
● minimum3
AWG number / as coded connectable conductor cross section / solid / according to CSA C22.2 No. 5-16
● minimum3
type of connectable conductor cross-sections / for copper conductor
● solid1x (16 ...185mm²)
● finely stranded / with core end processing1x (16...150mm²)
● stranded1x (16...185mm²)
type of connectable conductor cross-sections / for auxiliary contacts
● solidlateral auxiliary switch 2x (0,75 ... 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 ... 2,5mm²)
● finely stranded / with core end processinglateral auxiliary switch 2x (0,75 ... 1,5mm²), 1x 2,5mm²; front auxiliary switch 1x 2,5mm²
● strandedlateral auxiliary switch 2x (0,75 ... 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 ... 2,5mm²)
type of electrical connection
● for main current circuitbox terminal
● for auxiliary contactsconnection terminals
Requirements
design of the fuse link
● for short-circuit protection of the main circuit / requiredFuse gG: 125 A
● for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
Mechanical Design
height178 mm
width113 mm
depth158 mm
fastening methodBuilt-in unit fixed-mounted version
fastening method
● 4-hole front mountingYes
● front mounting with central attachmentNo
● rail mountingNo
net weight1 900 g
Environmental conditions
ambient temperature / during operation
● minimum-25 °C
● maximum55 °C
ambient temperature / during storage / minimum-25 °C

Downloads and manuals

General Product ApprovalDeclaration of Conformity

CSA

Confirmation

UL

EAC

UK Declaration of Conformity

EC/EU-Declaration of Conformity

other

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/12/2022


Additional data

Product
Article Number (Market Facing Number)3LD5410-0TK11
Product DescriptionSENTRON, Molded case switch 3LD5 UL, Main switch, 3-pole, certified according to UL489 UL60947-4-1 and IEC60947-3, UL: 100A, SCCR 65kA at 480VAC, Operating power at 480VAC 3-phase: 60hp, IEC: 100A, Operating power at AC-23A at 400V: 45kW, floor mounting with door coupling rotary operating mechanism, defeatable, Standard, 4-hole mounting of the handle, without tolerance compensation, incl. terminal covers for the infeed side
Product familyBasic Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12R / 1CL
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works130 Day/Days
Net Weight (kg)2,191 Kg
Packaging Dimension315,00 x 642,00 x 234,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869575568
UPCNot available
Commodity Code85365080
LKZ_FDB/ CatalogIDLV10
Product Group5887
Group CodeP360
Country of originGermany
Compliance with the substance restrictions according to RoHS directivenot available
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-14-03
eClass7.127-37-14-03
eClass827-37-14-03
eClass927-37-14-03
eClass9.127-37-14-03
ETIM5EC000216
ETIM6EC000216
ETIM7EC000216
ETIM8EC000216

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.