3LD2330-0TK13 SIEMENS SENTRON, switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 160 A, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3LD2330-0TK13 SIEMENS SENTRON, switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 160 A, ..

3LD2330-0TK13

SIEMENS

SENTRON, switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 160 A, operating performance / at AC-23 A at 400 V: 75 kW, installation in distribution boards, knob-operated mechanism, red/yellow, handle direct at the switch

More details


Low-voltage industrial components > Switch disconnector

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > SWITCHES-DISCONNECTORS

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $503.81
Unit price: $503.81

Quantity Price
1+$503.81
2+$503.81
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

SENTRON, switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 160 A, operating performance / at AC-23 A at 400 V: 75 kW, installation in distribution boards, knob-operated mechanism, red/yellow, handle direct at the switch
Model
product brand nameSENTRON
product designation3LD Switch disconnector
design of the productEMERGENCY-STOP switch
display version / for switch position indicator manual operation1 ON - 0 OFF
design of the actuating elementselector switch
design of handleknob-operated mechanism, red/yellow
type of the driving mechanism / motor driveNo
General technical data
number of poles3
type of devicefixed mounting
type of switchDIN-rail mounting
size of switch disconnector5
mechanical service life (switching cycles) / typical100 000
electrical endurance (switching cycles)
● at AC-23 A / at 690 V6 000
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum185 kA2.s
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum185 kA2.s
operating frequency / maximum50 1/h
Voltage
insulation voltage / rated value690 V
surge voltage resistance / rated value8 kV
Protection class
protection class IPIP40
protection class IP / on the frontIP40
Dissipation
power loss [W]
● for rated value of the current / at AC / in hot operating state / per pole36 W
● per conductor / typical36 W
Current
operational current
● at 40 °C / rated value160 A
● at 45 °C / rated value160 A
● at 50 °C / rated value160 A
● at 55 °C / rated value160 A
● at AC / rated value160 A
● at AC-23 A / at 400 V / rated value132 A
● at AC-21 / at 690 V / rated value160 A
● at AC-21 A / at 240 V / rated value160 A
● at AC-21 A / at 440 V / rated value160 A
operational current / of upstream fuse / rated value160 A
let-through current / with closed switch
● at 440 V / for combination switch + gG fuse / maximum15 kA
● at 690 V / for combination switch + gG fuse / maximum permissible15 kA
Main circuit
operating power
● at AC-23 A / at 240 V / rated value132 kW
● at AC-23 A / at 400 V / rated value132 kW
● at AC-23 A / at 440 V / rated value132 kW
● at AC-23 A / at 690 V / rated value45 kW
● at AC-3 / at 240 V / rated value35 kW
● at AC-3 / at 400 V / rated value50 kW
● at AC-3 / at 690 V / rated value37 kW
operational current / rated value160 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
operating voltage / of auxiliary contacts / at AC / maximum500 V
continuous current / of the auxiliary contact / rated value10 A
insulation voltage / of the auxiliary switch / rated value500 V
Suitability
suitability for use
● main switchYes
● switch disconnectorYes
● EMERGENCY OFF switchYes
● safety switchYes
● maintenance/repair switchYes
Appearance
color / of the actuating elementred
Product details
product feature
● can be locked into OFF positionYes
number of bracket locks / maximum3
hasp thickness / of the bracket locks / minimum4 mm
hasp thickness / of the bracket locks / maximum6 mm
product extension / optional
● motor driveNo
● voltage triggerNo
Short circuit
conditional short-circuit current / with line-side fuse protection
● at 690 V / by gG fuse / rated value50 kA
according UL
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value180 A
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value600 V
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value75
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value50
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-110 kA
continuous current / of upstream fuse / according to UL / rated value200 A
type of fuse / according to ULRK5
Number
number of connectable NC contacts / for auxiliary contacts / attachable / maximum2
number of connectable NO contacts / for auxiliary contacts / attachable / maximum4
number of connectable CO contacts / for auxiliary contacts / attachable / maximum0
Connections
AWG number / as coded connectable conductor cross section / solid
● minimum1
type of connectable conductor cross-sections / for copper conductor
● solid1x (16 ...185mm²)
● finely stranded / with core end processing1x (16...150mm²)
● stranded1x (16...185mm²)
type of connectable conductor cross-sections / for auxiliary contacts
● solid2x (0.75 ... 2.5 mm²), 1x 4 mm²
● finely stranded / with core end processing2x (0.75 ... 1.5 mm²), 1x 2.5 mm²
● stranded2x (0.75 ... 2.5 mm²), 1x 4 mm²
type of electrical connection
● for main current circuitbox terminal
● for auxiliary contactsconnection terminals
Requirements
design of the fuse link
● for short-circuit protection of the main circuit / requiredfuse gL/gG: 160 A
● for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
Mechanical Design
height169 mm
width112 mm
depth94 mm
fastening methodBuilt-in unit fixed-mounted version
fastening method
● 4-hole front mountingNo
● front mounting with central attachmentNo
● rail mountingNo
net weight2 048 g
Environmental conditions
ambient temperature / during operation
● minimum-25 °C
● maximum55 °C
ambient temperature / during storage / minimum-25 °C

Downloads and manuals

General Product ApprovalDeclaration of Conformity

CSA

Confirmation

CCC

UL

EAC

EC/EU-Declaration of Conformity

Declaration of ConformityTest Certificatesother

UK Declaration of Conformity

Special Test Certificate

Type Test Certificates/Test Report

Environmental Confirmations

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/15/2022


Additional data

Product
Article Number (Market Facing Number)3LD2330-0TK13
Product DescriptionSENTRON, switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 160 A, operating performance / at AC-23 A at 400 V: 75 kW, installation in distribution boards, knob-operated mechanism, red/yellow, handle direct at the switch
Product familyBasic Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12R / 1CL
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works130 Day/Days
Net Weight (kg)2,048 Kg
Packaging Dimension220,00 x 300,00 x 195,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209786974
UPC040892595949
Commodity Code85365080
LKZ_FDB/ CatalogIDLV10.1
Product Group5887
Group CodeP360
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 06.12.2008
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-14-03
eClass7.127-37-14-03
eClass827-37-14-03
eClass927-37-14-03
eClass9.127-37-14-03
ETIM5EC000216
ETIM6EC000216
ETIM7EC000216
ETIM8EC000216
UNSPSC1439-12-22-05
UNSPSC1539-12-22-33

ETIM data

ETIM: EC000216 - Switch disconnector

Value Unit
Version as main switch (EF006981) true
Version as maintenance-/service switch (EF006986) true
Version as safety switch (EF006985) true
Version as emergency stop installation (EF006959) true
Version as reversing switch (EF009408) false
Number of switches (EF005586) 1
Max. rated operation voltage Ue AC (EF007355) 690V
Rated permanent current Iu (EF001389) 160.0A
Rated permanent current at AC-23, 400 V (EF011777) -A
Rated permanent current at AC-21, 400 V (EF009165) 160A
Rated operation power at AC-3, 400 V (EF001364) 50.0kW
Rated short-time withstand current lcw (EF007050) 4.0kA
Rated operation power at AC-23, 400 V (EF007027) 0.132kW
Number of poles (EF001391) 3
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
Motor drive optional (EF007386) false
Motor drive integrated (EF006697) false
Voltage release optional (EF007491) false
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for floor mounting (EF007243) FALSE
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) false
Suitable for distribution board installation (EF007262) true
Suitable for intermediate mounting (EF007264) true
Colour control element (EF007167) Red
Type of control element (EF006976) Toggle
Interlockable (EF006281) true
Type of electrical connection of main circuit (EF006819) Frame clamp
Degree of protection (IP), front side (EF003118) IP40
Degree of protection (NEMA) (EF011959) Other
Rated operating voltage (EF001435) -V
Switching power at 400 V (EF009166) -kW
Conditioned rated short-circuit current Iq (EF001444) -kA


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.