ANUNCIAR
3KD2644-2ME40-0 SIEMENS Switch disconnector 63 A, Size 1, 4-pole Lateral operating mechanism right Basic uni.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3KD2644-2ME40-0 SIEMENS Switch disconnector 63 A, Size 1, 4-pole Lateral operating mechanism right Basic uni..

3KD2644-2ME40-0

SIEMENS

Switch disconnector 63 A, Size 1, 4-pole Lateral operating mechanism right Basic unit without handle Box terminal

SWITCH-DISCONNECTOR 63A, SIZE 1, 4 POLES ACCTO. RIGHT SIDE. BASE UNIT WITHOUT HANDLE FRAME TERMINALS.

More details


Low-voltage industrial components > Switch disconnector

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > 3KD Switch-disconnectors, 3KC Power Switches

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $152.07
Unit price: $152.07
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



ETIM: EC000216 - Switch disconnector

Value Unit
Degree of protection (NEMA) (EF011959) -
Number of switches (EF005586) -
Rated permanent current at AC-23, 400 V (EF011777) -A
Rated operating voltage (EF001435) -V
Version as main switch (EF006981) true
Version as maintenance-/service switch (EF006986) true
Version as safety switch (EF006985) true
Version as emergency stop installation (EF006959) true
Version as reversing switch (EF009408) false
Max. rated operation voltage Ue AC (EF007355) 690V
Rated permanent current Iu (EF001389) 63.0A
Rated permanent current at AC-21, 400 V (EF009165) 63A
Rated operation power at AC-23, 400 V (EF007027) 30.0kW
Switching power at 400 V (EF009166) 30.0kW
Number of poles (EF001391) 4
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 3
Motor drive optional (EF007386) false
Motor drive integrated (EF006697) false
Voltage release optional (EF007491) false
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for floor mounting (EF007243) FALSE
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) false
Suitable for distribution board installation (EF007262) true
Suitable for intermediate mounting (EF007264) true
Colour control element (EF007167) Other
Type of control element (EF006976) None
Interlockable (EF006281) false
Type of electrical connection of main circuit (EF006819) Frame clamp
Degree of protection (IP), front side (EF003118) IP20
Conditioned rated short-circuit current Iq (EF001444) -kA
Rated operation power at AC-3, 400 V (EF001364) -kW
Rated short-time withstand current lcw (EF007050) -kA


Switch disconnector 63 A, Size 1, 4-pole Lateral operating mechanism right Basic unit without handle Box terminal
Model
product brand nameSENTRON
Product designation3KD switch disconnector
Design of the productSwitch
Display version / for switch position indicator door-coupling rotary operating mechanismON-OFF
Design of the operating mechanismWithout handle
type of the driving mechanismSide operating mechanism
Type of the driving mechanism / motor driveNo
General technical data
number of poles4
Type of devicefixed mounting
Size of switch disconnector1
Electrical endurance (switching cycles)
● at AC-23 A / at 690 V6 000
● at DC-23 A / at 440 V1 500
● I2t value / with closed switch / for combination switch + fuse / at 500 V / maximum34 100 A²·s
● I2t value / with closed switch / for combination switch + fuse / at 400 V / maximum34 100 A²·s
● I2t value / with closed switch / at 415 V / for combination switch +molded case circuit breaker / maximum187 000 A²·s
● I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum41 190 A²·s
● I2t value / with closed switch / at 1000 V / for combination switch +gG/aM SITOR fuse / maximum2 331 A²·s
● I2t value / of the gG/aM SITOR fuse / at 1000 V / maximum permissible6 000 A²·s
● I2t value / of the molded case circuit breaker / at 415 V / maximum permissible480 000 A²·s
Mechanical service life (switching cycles) / typical15 000
Position / of the switch operating mechanismat the right end
Overvoltage in percent / relative to the operating voltage / at AC / at 400, 500, 690 V / at 50/60 Hz10 %
overvoltage categoryIII
Degree of pollution3
Voltage
Operating voltage / with current paths in series
● with degree of pollution 2 / at DC / rated value440 V / 3
● with degree of pollution 3 / at DC / rated value440 V / 3
Insulation voltage
● rated value1 000 V
Surge voltage resistance / rated value8 kV
Supply voltage
Operating current / at AC / rated value63 A
Operating voltage
● at AC / at 50/60 Hz / rated value1 000 V
Protection class
Protection class IPIP20
● Protection class IP / with closed switch / with cover or cable lug coverIP20
● protection class IP / on the frontIP20
Dissipation
Power loss [W]
● with conventional rated thermal current / per pole1 W
● with conventional rated thermal current / per device4 W
● for rated value of the current / at AC / in hot operating state / per pole1 W
Current
● Operating current / at AC-23 A / at 690 V / rated value63 A
● Operating current / at AC-23 A / at 500 V / rated value63 A
● Operating current / at AC-23 A / at 400 V / rated value63 A
● Operating current / at AC-22 A / at 690 V / rated value63 A
● Operating current / at AC-22 A / at 500 V / rated value63 A
● Operating current / at AC-22 A / at 400 V / rated value63 A
● Operating current / at AC-20 A / at 1000 V / maximum63 A
● Operating current / at AC-21 A / at 400 V / rated value63 A
● Operating current / at AC-21 A / at 500 V / rated value63 A
● Operating current / at AC-21 A / at 690 V / rated value63 A
● Operating current / at AC-23 A / at 500 V / at 50/60 Hz / rated value / maximum63 A
● Operating current / at AC-22 A / at 500 V / at 50/60 Hz / rated value / maximum63 A
● Operating current / at AC-22 A / at 400 V / at 50/60 Hz / rated value / maximum63 A
● Operating current / at AC-22 A / at 690 V / at 50/60 Hz / rated value / maximum63 A
● Operating current / at AC-23 A / at 400 V / at 50/60 Hz / rated value / maximum63 A
● Operating current / at AC-23 A / at 690 V / at 50/60 Hz / rated value / maximum63 A
Continuous current
● rated value63 A
● at 40 °C / rated value63 A
● at 45 °C / rated value63 A
● at 50 °C / rated value63 A
● at 55 °C / rated value63 A
● at 60 °C / rated value63 A
● at 65 °C / rated value63 A
● at 70 °C / rated value63 A
Continuous current / of upstream fuse / at 500 V and 690 V / rated value100 A
Continuous current / of upstream fuse / at 1000 V / rated value100 A
Continuous current / of upstream molded case circuit breaker / at 415 V / rated value100 A
Operating current / at DC / rated value63 A
let-through current / of the fuse / at 500 V / maximum permissible12 500 A
let-through current / of the gG fuse / at 690 V / maximum permissible14 700 A
let-through current / of the gG/aM SITOR fuse / at 1000 V / maximum permissible4 700 A
let-through current / of the molded case circuit breaker / at 415 V / maximum permissible20 000 A
let-through current / with closed switch
● at 690 V / for combination switch + gG fuse / maximum permissible11 500 A
● at 415 V / for combination switch +molded case circuit breaker / maximum permissible12 400 A
● at 1000 V / for combination switch +gG/aM SITOR fuse / maximum permissible5 057 A
● for combination switch + fuse / at 400 V / maximum permissible13 100 A
● for combination switch + fuse / at 500 V / maximum permissible13 100 A
Main circuit
Operating power
● at AC-23 A / at 400 V / at 50/60 Hz / rated value30 kW
● at AC-23 A / at 500 V / rated value37 kW
● at AC-23 A / at 690 V / at 50/60 Hz / rated value55 kW
Operating current / rated value63 A
Auxiliary circuit
Number of connected NC contacts / for auxiliary contacts0
Number of connected NO contacts / for auxiliary contacts0
Number of connected CO contacts / for auxiliary contacts0
Number of CO contacts / for auxiliary contacts3
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Suitability
Suitability for use
● Main switchYes
● switch disconnectorYes
● EMERGENCY OFF switchYes
● safety switchYes
● maintenance/repair switchYes
Product details
product feature / interlockNo
Product component
● Trip indicatorNo
● Voltage triggerNo
● undervoltage releaseNo
● undervoltage release with leading contactNo
Product extension / Auxiliary switchYes
Product extension / optional
● motor driveNo
● Voltage triggerNo
Short circuit
Short-time withstand current (Icw) / at AC 1000 V/DC 440 V / limited to 1 s / rated value3 kA
Short-circuit current making capacity (Icm)
● for switch disconnector / at 1000 V AC / without fuse link / rated value / minimum7 kA
● for switch disconnector / at DC 440 V / without fuse link / rated value / minimum7 kA
● for switch disconnector / without fuse link / rated value / minimum7 kA
Conditional short-circuit current / with line-side fuse protection
● at 415 V / by molded case circuit breaker / rated value36 kA
● at 500 V / by gG fuse / rated value100 kA
● at 690 V / by gG fuse / rated value100 kA
Connections
Type of connectable conductor cross-sections
● with flexible busbar2x (0,8x9 mm²)
Type of connectable conductor cross-sections
● for copper busbar'1 x (2 x 9 mm²)
Type of connectable conductor cross-sections / for copper conductor
● solid1x (1 ... 16 mm²)
● finely stranded / with core end processing1x (1 ... 35 mm²)
● stranded1x (6 ... 35 mm²)
Type of electrical connection
● for main current circuitbox terminal
Mechanical Design
Height119 mm
Width121.3 mm
Depth69.5 mm
Mounting typeScrew fixing and standard rail mounting 35 mm
● Mounting type / front mounting with 4-hole attachmentNo
● Mounting type / front mounting with central attachmentNo
● mounting type / rail mountingYes
mounting positionany
net weight1 047 g
Environmental conditions
Ambient temperature / during operation
● minimum-25 °C
● maximum70 °C
Ambient temperature / during storage
● minimum-50 °C
● maximum80 °C
Certificates
● reference code / acc. to DIN EN 61346-2Q
● Reference code / acc. to DIN EN 81346-2Q
General Product ApprovalDeclaration of ConformityShipping Approvalother

CCC

VDE

Miscellaneous

EC/EU-Declaration of Conformity

LR (Lloyds Register)

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications


Product
Article Number (Market Facing Number)3KD2644-2ME40-0
Product DescriptionSwitch disconnector 63 A, Size 1, 4-pole Lateral operating mechanism right Basic unit without handle Box terminal
Product familyBasic Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group12S
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works5 Day/Days
Net Weight (kg)1,047 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension121,30 x 69,50 x 119,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869514369
UPCNot available
Commodity Code85365080
LKZ_FDB/ CatalogIDLV10.1
Product Group5378
Group CodeP360
Country of originChina
Compliance with the substance restrictions according to RoHS directiveSince: 24.11.2009
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-14-03
eClass7.127-37-14-03
eClass827-37-14-03
eClass927-37-14-03
eClass9.127-37-14-03
ETIM4EC000216
ETIM5EC000216
ETIM6EC000216
ETIM7EC000216
UNSPSC1439-12-22-05
UNSPSC1539-12-22-33

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.