5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: M22-D-S
Code: 216590
Catalog Number: Y7-216590
Manufacturer: EATON - MOELLER
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER
Calculate price by quantity
| Quantity | Price |
|---|---|
More units, standard lead time: 5 days.
LAST VIEWED
| Product Name | Eaton Moeller® series M22 Pushbutton |
| Catalog Number | 216590 |
| Model Code | M22-D-S |
| EAN | 4015082165901 |
| Product Length/Depth | 30 mm |
| Product Height | 30 mm |
| Product Width | 30 mm |
| Product Weight | 0.009 kg |
| Compliances | CE Marked |
| Certifications | IEC 60947-5 EN 60947-5 UL 508 CSA Std. C22.2 No. 94-91 CSA Std. C22.2 No. 14-05 VDE CSA CSA-C22.2 No. 94-91 UL File No.: E29184 CE IEC/EN 60947 UL Category Control No.: NKCR VDE 0660 UL CSA Class No.: 3211-03 CSA File No.: 012528 CSA-C22.2 No. 14-05 IEC/EN 60947-5 DNV GL LR |
| Bezel color | Titanium |
| Bezel material | Plastic |
| Color | Black |
| Design | Flat Classical |
| Fitted with: | Front ring |
| Inscription | Blank |
| Degree of protection | IP69K NEMA 13 NEMA 3R IP67 IP66 NEMA 4X NEMA 12 |
| Degree of protection (front side) | NEMA 4X IP67/IP69K |
| Lifespan, mechanical | 5,000,000 Operations |
| Opening diameter | 22.5 mm |
| Operating frequency | 3600 Operations/h |
| Product category | RMQ-Titan |
| Product category | RMQ-Titan |
| Size | Front dimensions: 22 x 22 mm |
| Type | Pushbutton actuator |
| Mounting position | As required |
| Shock resistance | Mechanical, According to IEC/EN 60068-2-27 30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 70 °C |
| Ambient storage temperature - min | 40 °C |
| Ambient storage temperature - max | 80 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
| Connection to SmartWire-DT | Yes With SWD-RMQ connections |
| Actuating force | 5 N |
| Actuator color | Black |
| Actuator function | Spring-return Momentary |
| Force for positive opening - min | 0 N |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | Not applicable. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP