— Scott 12/21/18, 12:00 AM
Button
Button is as advertised. Top quality at a very good price.

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: M22-PV
Code: 216876
Catalog Number: Y7-216876
Manufacturer: EATON - MOELLER
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER
LAST VIEWED
| Product Name | Eaton Moeller® series M22 emergency stop/emergency switching off pushbutton |
| Catalog Number | 216876 |
| Model Code | M22-PV |
| EAN | 4015082168766 |
| Product Length/Depth | 38 mm |
| Product Height | 70 mm |
| Product Width | 38 mm |
| Product Weight | 0.039 kg |
| Compliances | CE Marked |
| Certifications | EN 60947-5 CSA Std. C22.2 No. 94-91 IEC 60947-5 UL 508 CSA Std. C22.2 No. 14-05 VDE UL CE CSA File No.: 012528 IEC/EN 60947-5 CSA IEC/EN 60947 UL File No.: E29184 CSA Class No.: 3211-03 CSA-C22.2 No. 14-05 CSA-C22.2 No. 94-91 VDE 0660 UL Category Control No.: NKCR DNV GL LR |
| Catalog Notes | Max. number of contacts: four M22-(C)K01, …10 or two M22-(C)K02, …20, …11 |
| Type | Controlled stop pushbutton/emergency-stop button |
| Actuator color | Red |
| Features | Tamper-proof (according to ISO 13850, EN 418) |
| Actuator function | Pull-to-release Switching function latching |
| 10.10 Temperature rise | Not applicable. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Operating frequency | 600 Operations/h |
| Button color | Red |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
| Connection to SmartWire-DT | No |
| Base color | Yellow |
| Actuating force | 50 N |
| Actuator diameter | 38 mm |
| Ambient operating temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Diameter cap | 38 mm |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Force for positive opening - min | 0 N |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Opening diameter | 22.5 mm |
| Opening height | 0 mm |
| RAL-number | 3000 |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Illumination | Non-illuminated |
| Bezel color | Other |
| Shock resistance | Mechanical, According to IEC/EN 60068-2-27 50 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms |
| Color | Red |
| Bezel material | Other |
| Design | Mushroom-shaped Classical |
| Mounting position | As required |
| Degree of protection | IP66 NEMA 4X, 13 |
| Front element type | High |
| Lens type | Round |
| Lifespan, mechanical | 100,000 Operations |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| Width opening | 0 mm |
| Product category | RMQ-Titan |
| Size | Front dimensions: 35 mm |
| Supply voltage lamp | 0 V |
| Suitable for | Emergency stop |
| Unlocking method | Pull-release |
— Scott 12/21/18, 12:00 AM
Button is as advertised. Top quality at a very good price.
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP