EATON - MOELLER E10 090351 Y7-90351 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

E10 090351 Y7-90351 EATON ELECTRIC Contact element, 1N/O, front mount, screw connection

Reference: E10

Code: 090351

Catalog Number: Y7-90351

Manufacturer: EATON - MOELLER

Description:

Contact element, 1N/O, front mount, screw connection
Contact Element 1 NO Front Mount Screw Connection For
Eaton Moeller® series E10 Accessory Contact element, 1 N/O, Front fastening, Blade terminal
Contact element, Product range: Accessories, Single unit, Connection technique: Blade terminal, Description: admissible operating voltage: 5 – 250 V, Contacts N/O = Normally open: 1 N/O, Degree of Protection: IP20 with ISH2,8, Connection to SmartWire-DT: no

Categories:

  • Low-voltage industrial components > Auxiliary contact block
  • EATON - MOELLER > Auxiliary Control and Signalling Elements

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton Moeller® series E10 Accessory Contact element
Catalog Number
090351
Model Code
E10
EAN
4015080903512
Product Length/Depth
6 mm
Product Height
29 mm
Product Width
18 mm
Product Weight
0.003 kg
Certifications
CE
UL Category Control No.: NKCR
UL
CSA-C22.2 No. 14-05
IEC/EN 60947
UL 508
UL File No.: E29184
CSA
CSA Class No.: 3211-03
CSA File No.: 46552
IEC/EN 60947-5

Features & Functions

Electric connection type
Screw connection

General

Degree of protection
IP20, with Insulated ferrule ISH2,8
Lifespan, mechanical
100,000,000 Operations
Model
Top mounting
Mounting method
Front fastening
Operating frequency
3600 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Accessories
Rated impulse withstand voltage (Uimp)
4000 V AC
Terminal capacity
0.5 - 1.0 mm²
Terminal size
2.8 x 0.8 mm to DIN 46247 and IEC 60760, Fast-on connectors
2.8 x 0.8 mm to DIN 46244, Blade terminal

Ambient conditions, mechanical

Mounting position
As required
Shock resistance
40 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Electrical rating

Rated insulation voltage (Ui)
250 V
Rated operational current (Ie)
4 A at AC-15, 110 V
4 A at AC-15, 48 V
Rated operational current (Ie) at AC-15, 24 V
4 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
6 A
Rated operational current (Ie) at DC-13, 24 V
1.5 A
Rated operational current (Ie) at DC-13, 42 V
1 A
Rated operational current (Ie) at DC-13, 60 V
0.8 A
Rated operational current (Ie) at DC-13, 110 V
0.5 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.2 A
Rated operational voltage (Ue) at AC - max
250 V
Short-circuit protection
FAZ-B6/1, Fuseless
Short-circuit protection rating
Max. 10 A gG/gL, Fuse, Contacts

Actuator

Actuating force - max
3 N

Communication

Connection to SmartWire-DT
No
Connection type
Blade terminal

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.1 W
Rated operational current for specified heat dissipation (In)
4 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 090351 Low-voltage industrial controls and switchgear (EC000041)

Feature nameNumber of contacts as change-over contact (EF008257)
Feature value0
Feature nameNumber of contacts as normally open contact (EF008256)
Feature value1
Feature nameNumber of contacts as normally closed contact (EF008255)
Feature value0
Feature nameNumber of fault-signal switches (EF007613)
Feature value0
Feature nameRated operation current Ie at AC-15, 230 V (EF001385)
Feature value6 A
Feature nameType of electric connection (EF003961)
Feature valueScrew connection
Feature nameModel (EF000010)
Feature valueClip-on
Feature nameMounting method (EF000003)
Feature valueFront fastening
Feature nameLamp holder (EF000048)
Feature valueNone

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.