| Product Name | Eaton Moeller® series LS Position switch |
| Catalog Number | 106823 |
| Model Code | LS-S02-24DFT-ZBZ/X |
| EAN | 4015081065837 |
| Product Length/Depth | 55 mm |
| Product Height | 170 mm |
| Product Width | 37 mm |
| Product Weight | 0.43 kg |
| Certifications | IEC/EN 60947 UL 508 CSA File No.: 012528 CE CSA-C22.2 No. 14 UL File No.: E29184 CSA UL CSA Class No.: 3211-03 IEC/EN 60947-5 UL Category Control No.: NKCR |
| Electric connection type | Cable entry metrical |
| Enclosure material | Plastic Insulated material |
| Features | Expandable Forced opening |
| Fitted with: | Auxiliary release mechanism Interlock monitoring |
| Switch function type | Slow-action switch |
| Connection type | Screw terminal |
| Degree of protection | IP65 NEMA Other |
| Duty factor | 100 % (Magnet) |
| Lifespan | 1,000,000 mechanical Operations |
| Operating frequency | 800 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Basic units with spring-powered interlock (closed-circuit principle) |
| Rated impulse withstand voltage (Uimp) | 4000 V AC |
| Repetition accuracy | 0.02 mm (Contacts/switching capacity) |
| Suitable for | Safety functions |
| Type |
|
| Mounting position | As required |
| Shock resistance | 10 g, Standard-action contact, Mechanical, Half-Sinusoidal shock 20 ms |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 70 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Terminal capacity (flexible with ferrule) | 2 x (0.5 - 1.5) mm² 1 x (0.5 - 1.5) mm² |
| Terminal capacity (solid) | 1 x (0.75 - 2.5) mm² 2 x (0.75 - 1.5) mm² |
| Screw size | PH1, Terminal screw |
| Tightening torque | 0.9 Nm, Screw terminals |
| Power consumption | 8 W at 24 V DC (electromechanical actuation) 11 VA at 230 V AC (electromechanical actuation) 8 VA at 120 V AC (electromechanical actuation) |
| Rated conditional short-circuit current (Iq) | 1 kA |
| Rated control supply voltage | 24 V DC (Us, for magnet drive) |
| Rated insulation voltage (Ui) | 400 V |
| Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V | 6 A |
| Rated operational current (Ie) at AC-15, 24 V | 6 A |
| Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V | 4 A |
| Rated operational current (Ie) at DC-13, 110 V | 0.8 A |
| Rated operational current (Ie) at DC-13, 125 V | 0.8 A |
| Rated operational current (Ie) at DC-13, 220 V, 230 V | 0.3 A |
| Rated operational current (Ie) at DC-13, 24 V | 3 A |
| Short-circuit protection rating | Max. 6 A gG/gL, Fuse, Contacts |
| Supply frequency | Max. 400 Hz, Contacts |
| Voltage tolerance | 1.1 x Us, Pick-up and drop-out values 0.85 x Us, Pick-up and drop-out values |
| Actuating force at beginning/end of stroke | 25 N/15 N (plug-in/pull-out) |
| Actuator type | None |
| Mechanical holding force | 1200 N (according to GS-ET-19 (04/2004), XNW) 1600 N (according to GS-ET-19 (04/2004), XWA, XFG, XF) 1700 N (according to GS-ET-19 (04/2004), XG, XW, XNG) |
| Number of contacts (change-over contacts) | 0 |
| Number of contacts (normally closed contacts) | 2 |
| Number of contacts (normally open contacts) | 0 |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0.13 W |
| Rated operational current for specified heat dissipation (In) | 6 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP