EATON - MOELLER LS-S02-230AFT-ZBZ/X 106821 Y7-106821 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

LS-S02-230AFT-ZBZ/X 106821 Y7-106821 EATON ELECTRIC Position switch, 2 N/C, basic, spring-powered interlock

Reference: LS-S02-230AFT-ZBZ/X

Code: 106821

Catalog Number: Y7-106821

Manufacturer: EATON - MOELLER

Description:

Position switch, 2 N/C, basic, spring-powered interlock
LS-S02-230AFT-ZBZ/X
Eaton Moeller® series LS Position switch, 2 N/C, basic, spring-powered interlock LS-S02-230AFT-ZBZ/X
Position switch, Basic function: Position switches, Safety position switches, Part group reference: LS…ZBZ/X, Product range: Basic units with spring-powered interlock (closed-circuit principle), Degree of Protection: IP65, Features: Basic device, expandable, Ambient temperature: -25 - +40 °C, Description: With interlock monitoring, with auxiliary release mechanism, Monitoring of door position: continuous, Contacts N/C = Normally closed: 2 NC, Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Rated control voltage for magnetic drive: Us= 230 V 50/60 Hz V, Housing: Insulated material, Connection type: Screw terminal , Standards: IEC/EN 60947

Categories:

  • Sensors > End switch
  • EATON - MOELLER > Position Switches

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 166,64 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton Moeller® series LS Position switch
Catalog Number
106821
Model Code
LS-S02-230AFT-ZBZ/X
EAN
4015081065813
Product Length/Depth
55 mm
Product Height
170 mm
Product Width
37 mm
Product Weight
0.417 kg
Certifications
CSA File No.: 012528
UL Category Control No.: NKCR
CSA
CSA-C22.2 No. 14
IEC/EN 60947
IEC/EN 60947-5
CE
UL File No.: E29184
CSA Class No.: 3211-03
UL
UL 508

Product specifications

Type
Features
Forced opening
Expandable
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Electric connection type
Cable entry metrical
Enclosure material finishing
Other
Fitted with:
Interlock monitoring
Auxiliary release mechanism
Operating frequency
800 Operations/h
Pollution degree
3
Actuator alignment
Other
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Enclosure material
Plastic
Insulated material
Enclosure type
Cuboid
Rated operational current (Ie) at DC-13, 110 V
0.8 A
Rated operational current (Ie) at DC-13, 125 V
0.8 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.3 A
Rated operational current (Ie) at DC-13, 24 V
3 A
Rated operational current for specified heat dissipation (In)
6 A
Sensor height
173 mm
Sensor length
39 mm
Static heat dissipation, non-current-dependent Pvs
0 W
Width sensor
60 mm
Product category
Basic units with spring-powered interlock (closed-circuit principle)
Action
2021118113756-Mechanical Limit Switches.xlsm-Data
Force for positive opening - min
50 N
Rated impulse withstand voltage (Uimp)
4000 V AC
Actuating force at beginning/end of stroke
25 N/15 N (plug-in/pull-out)
Explosion safety category for dust
None
Explosion safety category for gas
None
Actuator type
None
Ambient operating temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Diameter sensor
0 mm
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.13 W
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
2
Number of contacts (normally open contacts)
0
Number of safety auxiliary contacts
2
Rated insulation voltage (Ui)
400 V
Rated operational current (Ie) at AC-15, 125 V
6 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
6 A
Rated operational current (Ie) at AC-15, 24 V
6 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
4 A
Mounting position
As required
Rated conditional short-circuit current (Iq)
1 kA
Overvoltage category
III
Connection type
Screw terminal
Duty factor
100 % (Magnet)
Degree of protection
IP65
NEMA Other
Interface type
None
Switch function type
Slow-action switch
Voltage tolerance
0.85 x Us, Pick-up and drop-out values
1.1 x Us, Pick-up and drop-out values
Screw size
PH1, Terminal screw
Lifespan
1,000,000 mechanical Operations
Rated control supply voltage
230 V 50/60 Hz (Us, for magnet drive)
Repetition accuracy
0.02 mm (Contacts/switching capacity)
Shock resistance
10 g, Standard-action contact, Mechanical, Half-Sinusoidal shock 20 ms
Mechanical holding force
1700 N (according to GS-ET-19 (04/2004), XG, XW, XNG)
1200 N (according to GS-ET-19 (04/2004), XNW)
1600 N (according to GS-ET-19 (04/2004), XWA, XFG, XF)
Supply frequency
Max. 400 Hz, Contacts
Suitable for
Safety functions
Power consumption
8 VA at 120 V AC (electromechanical actuation)
11 VA at 230 V AC (electromechanical actuation)
8 W at 24 V DC (electromechanical actuation)
Tightening torque
0.9 Nm, Screw terminals
Short-circuit protection rating
Max. 6 A gG/gL, Fuse, Contacts
Terminal capacity (flexible with ferrule)
1 x (0.5 - 1.5) mm²
2 x (0.5 - 1.5) mm²
Terminal capacity (solid)
2 x (0.75 - 1.5) mm²
1 x (0.75 - 2.5) mm²

ETIM for 106821 Sensors (EC000030)

Feature nameWidth sensor (EF007094)
Feature value60 mm
Feature nameDiameter sensor (EF007111)
Feature value0 mm
Feature nameHeight of sensor (EF007283)
Feature value173 mm
Feature nameLength of sensor (EF007334)
Feature value39 mm
Feature nameRated operation current Ie at AC-15, 24 V (EF007084)
Feature value6 A
Feature nameRated operation current Ie at AC-15, 125 V (EF007082)
Feature value6 A
Feature nameRated operation current Ie at AC-15, 230 V (EF001385)
Feature value6 A
Feature nameRated operation current Ie at DC-13, 24 V (EF007087)
Feature value3 A
Feature nameRated operation current Ie at DC-13, 125 V (EF007085)
Feature value0.8 A
Feature nameRated operation current Ie at DC-13, 230 V (EF001386)
Feature value0.3 A
Feature nameSwitching function (EF000189)
Feature valueSlow-action switch
Feature nameSwitching function latching (EF007447)
Feature valueNo
Feature nameOutput electronic (EF006987)
Feature valueNo
Feature nameForced opening (EF006694)
Feature valueYes
Feature nameNumber of safety auxiliary contacts (EF006940)
Feature value2
Feature nameNumber of contacts as normally closed contact (EF008255)
Feature value2
Feature nameNumber of contacts as normally open contact (EF008256)
Feature value0
Feature nameNumber of contacts as change-over contact (EF008257)
Feature value0
Feature nameType of interface (EF006977)
Feature valueNone
Feature nameType of interface for safety communication (EF003956)
Feature valueNone
Feature nameConstruction type housing (EF004008)
Feature valueCuboid
Feature nameHousing material (EF001596)
Feature valuePlastic
Feature nameCoating housing (EF001601)
Feature valueOther
Feature nameType of control element (EF006976)
Feature valueNone
Feature nameAlignment of the control element (EF008793)
Feature valueOther
Feature nameType of electric connection (EF003961)
Feature valueCable entry metrical
Feature nameWith status indication (EF001602)
Feature valueNo
Feature nameSuitable for safety functions (EF001597)
Feature valueYes
Feature nameExplosion safety category for gas (EF003997)
Feature valueNone
Feature nameExplosion safety category for dust (EF003998)
Feature valueNone
Feature nameAmbient temperature during operating (EF007515)
Feature value-25 °C
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP65
Feature nameDegree of protection (NEMA) (EF011959)
Feature valueOther

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.