Orderkey | 2811828 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 127 (C-5-2017) |
GTIN | 4046356579483 |
Weight per Piece (excluding packing) | 120.000 g |
Custom tariff number | 85437090 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -20 °C ... 65 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 2000 m |
Permissible humidity (operation) | typ. 5 % ... 95 % (non-condensing) |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
---|---|
Sensor types that can be used (TC) | B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG |
Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
Input signal range | 0 Ω ... 50 kΩ |
Potentiometer resistance range | 0 Ω ... 50 kΩ |
Input signal range | -1000 mV ... 1000 mV |
Configurable/programmable | Yes |
---|---|
Max. voltage output signal | ± 11 V |
Current output signal | 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL) |
Max. current output signal | 22 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/output load current output | ≤ 600 Ω (at 20 mA) |
Behavior in the event of a sensor error | according to NE 43 or freely configurable |
Output name | Relay output |
Configurable/programmable | Yes |
Contact type | 3 PDTs |
Contact material | AgSnO2, hard gold-plated |
Maximum switching voltage | 250 V AC (250 V DC) |
Maximum inrush current | 2 A (250 V AC) |
2 A (28 V DC) |
Supply voltage range | 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz) |
---|---|
Power consumption | < 2.4 W |
Conductor cross section solid min. | 0.2 mm² |
---|---|
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Connection method | Push-in connection |
Maximum transmission error | 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA) |
---|---|
Maximum temperature coefficient | 0.01 %/K |
Flammability rating according to UL 94 | V0 |
Degree of pollution | 2 |
Overvoltage category | II |
Electromagnetic compatibility | Conformance with EMC directive |
Housing material | PA 6.6-FR |
Color | gray |
Designation | Input/output/power supply |
Electrical isolation | 300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1)) |
2.5 kV (50 Hz, 1 min., test voltage) | |
Designation | Input/output |
Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
Designation | Input/power supply |
Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
Designation | Input/switching output |
Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA nC ic IIC T4 Gc X |
IECEx | Ex nA nC ic IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T6 | |
Class I, Zone 2, Group IIC T6 | |
SIL | 2 |
Electromagnetic compatibility | Conformance with EMC directive |
---|---|
Electrical isolation | 4-way, between input/output/power supply/switching output |
Flammability rating according to UL 94 | V0 |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA nC ic IIC T4 Gc X |
IECEx | Ex nA nC ic IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T6 | |
Class I, Zone 2, Group IIC T6 | |
DNV GL-Temperature | B |
DNV GL-Humidity | B |
DNV GL-Vibration | A |
DNV GL-EMC | A |
DNV GL-Enclosure | Required protection according to the Rules shall be provided upon installation on board |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PHOENIX CONTACT-2811828-MACX MCR-T-UIREL-UP-SP | 132 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.