Key Commercial Data

Orderkey2313944
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 335 (C-8-2015)
GTIN4046356579445
Weight per Piece (excluding packing)124.200 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width22.5 mm
Height99 mm
Depth56 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)30 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20

General

Electrical isolationDIN EN 50178 (RS-485 // VCC)
Test voltage data interface/power supply1.5 kVrms(50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Net weight124.2 g
Housing materialPA 6.6-FR
Colorgreen
MTBF2383 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
559 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF3550 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
1818 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
849 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USAClass I, Zone 2, AEx nA IIC T5
UL, USA/Canada508 Listed
Class I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, zone 2, Ex nA IIC T5 Gc X

Power supply

Nominal supply voltage24 V DC (via pluggable COMBICON screw terminal block)
Supply voltage range19.2 V DC ... 28.8 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption45 mA (24 V DC)

Serial interface

Interface 1PROFIBUS acc. to IEC 61158, RS-485 2-conductor
Connection methodD-SUB 9, COMBICON
Transmission length≤ 1200 m (Depends on transmission speed and cable type)
Termination resistor390 Ω
220 Ω
390 Ω (Can be connected)
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Serial transmission speed≤ 12 Mbps
Output nominal voltage5 V DC

Function

Status and diagnostic indicatorsLEDs: UL (communications power), data activity (not marked)

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testFree fall in acc. with IEC 60068-2-32
Test result1 m
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result25g, 11 ms period, half-sine shock pulse
Free from substances that could impair the application of coatingaccording to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 3 GHz (Test Level 3)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 1 kV (Data line, asymmetrical)
Standards/regulationsEN 61000-6-4
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USAClass I, Zone 2, AEx nA IIC T5
UL, USA/Canada508 Listed
Class I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, zone 2, Ex nA IIC T5 Gc X
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.