Product successfully added to your shopping cart
PSI-TERMINATOR-PB
2313944
PHOENIX_CONTACT
1
Termination resistor
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2313944 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 335 (C-8-2015) |
GTIN | 4046356579445 |
Weight per Piece (excluding packing) | 124.200 g |
Custom tariff number | 85389091 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -20 °C ... 65 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
Degree of protection | IP20 |
Electrical isolation | DIN EN 50178 (RS-485 // VCC) |
---|---|
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Net weight | 124.2 g |
Housing material | PA 6.6-FR |
Color | green |
MTBF | 2383 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
559 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
MTTF | 3550 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
1818 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
849 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
UL, USA | Class I, Zone 2, AEx nA IIC T5 |
UL, USA/Canada | 508 Listed |
Class I, Div. 2, Groups A, B, C, D | |
UL, Canada | Class I, zone 2, Ex nA IIC T5 Gc X |
Nominal supply voltage | 24 V DC (via pluggable COMBICON screw terminal block) |
---|---|
Supply voltage range | 19.2 V DC ... 28.8 V DC (via pluggable COMBICON screw terminal block) |
Typical current consumption | 45 mA (24 V DC) |
Interface 1 | PROFIBUS acc. to IEC 61158, RS-485 2-conductor |
---|---|
Connection method | D-SUB 9, COMBICON |
Transmission length | ≤ 1200 m (Depends on transmission speed and cable type) |
Termination resistor | 390 Ω |
220 Ω | |
390 Ω (Can be connected) | |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Serial transmission speed | ≤ 12 Mbps |
Output nominal voltage | 5 V DC |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Type of test | Free fall in acc. with IEC 60068-2-32 |
Test result | 1 m |
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result | 25g, 11 ms period, half-sine shock pulse |
Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 3 GHz (Test Level 3) |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 1 kV (Data line, asymmetrical) |
Standards/regulations | EN 61000-6-4 |
EN 61000-4-6 | |
Frequency range | 0.15 MHz ... 80 MHz |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA | Class I, Zone 2, AEx nA IIC T5 |
UL, USA/Canada | 508 Listed |
Class I, Div. 2, Groups A, B, C, D | |
UL, Canada | Class I, zone 2, Ex nA IIC T5 Gc X |
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2313944-PSI-TERMINATOR-PB | 265 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.