Double-level modular terminal block with two-stage surge protection for one two-wire impedance-sensitive signal circuit, separate ground connection, nominal voltage: 24 V DC.

More details


Programmable Logic Controllers Plcs

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+52,45 €
20+51,64 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height100 mm
Width6.2 mm
Depth63.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesIEC 60664-1
Note on clearances and creepage distances2007
Mounting typeDIN rail: 35 mm
TypeDouble-level terminal block
Number of positions2
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationC1
C2
C3
D1
VDE requirement classC1
C2
C3
D1
Nominal voltage UN24 V DC (21 V AC)
Maximum continuous voltage UC30 V DC
21 V AC
Nominal current IN350 mA
Operating effective current IC at UC≤ 1 µA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (Core-Core)300 A
Nominal discharge current In (8/20) µs (Core-Earth)5 kA
Total surge current (8/20) µs10 kA
Nominal pulse current Ian (10/1000) µs (Core-Core)10 A
Nominal pulse current Ian (10/1000) µs (Core-Earth)50 A
Impulse discharge current (10/350)˽µs, peak value limp500 A (per path)
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 45 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 950 V
Output voltage limitation at (8/20) µs (core-core)≤ 50 V (at 300 A)
Output voltage limitation at (8/20) µs (core-earth)≤ 950 V (at 5 kA)
Residual voltage at In (conductor-conductor)≤ 50 V
Residual voltage at In (conductor-ground)≤ 950 V
Voltage protection level Up (core-core)≤ 50 V (C1 - 0,6 kV / 300 A)
≤ 45 V (C3 - 10 A)
Voltage protection level Up (core-ground)≤ 950 V (C2 - 10 kV / 5 kA)
≤ 950 V (C3 - 50 A)
Response time tA (Core-Core)≤ 1 ns
Response time tA (Core-Earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.1 dB (500 kHz/50 Ω system)
typ. 0.1 dB (200 kHz/150 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ohm system3 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm system1 MHz
Capacity (Core-Core)≤ 2 nF
Surge protection fault messageNone
Max. required back-up fuse370 mA
Impulse durability (conductor-conductor)C1 - 0,6 kV / 300 A
C3 - 10 A, 50 A
Impulse durability (conductor-ground)C2 - 10 kV/5 kA
D1 - 500 A
Alternating current carrying capacity (conductor-ground)5 A - 1 s (typical)

Connection data

Connection methodSpring-cage connection
Connection type INSpring-cage
Connection type OUTSpring-cage
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Datasheet - PDF