ANUNCIAR
STU 35/ 4X10 BU 3033210 PHOENIX CONTACT Potential collective terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

STU 35/ 4X10 BU 3033210 PHOENIX CONTACT Potential collective terminal

STU 35/ 4X10 BU

3033210

PHOENIX_CONTACT

25

Potential collective terminal

Collective potential terminal, nominal voltage: 1000 V, nominal current: 41 A, number of connections: 5, connection type: Spring connection, Branch, Dimensioning cross-section: 6 mm², cross-section: 0.2 mm² - 10 mm², Screw connection, Collective connection, Dimensioning cross-section: 35 mm², cross-section: 1.5 mm² - 50 mm², mounting class: NS 35/7.5, NS 35/15, colour: blue

Potential collector terminals, nominal voltage: 1000 V, nominal current: 41 A, Branch, connection type: Spring connection, Reference section: 6 mm2, cross-section: 0.2 mm2 - 10 mm2, Collective connection, connection type: Screwed connection, Reference section: 35 mm2, Cross-section: 1.5 mm2 - 50 mm2, Mounting: NS 35/7.5, NS 35/15, Colour: blue

More details


Terminal blocks > Feed-through terminal block

Modular TBs

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $477.52
Unit price: $19.10
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey3033210
Packing unit25 pc
Minimum order quantity25 pc
Catalog pagePage 195 (C-1-2017)
GTIN4046356296045
Weight per Piece (excluding packing)55.040 g
Custom tariff number85369010
Country of originCN (China)

General

Number of levels1
Number of connections5
Nominal cross section35 mm²
Colorblue
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition4.06 W
Ambient temperature (operation)-60 °C ... 130 °C
Connection methodSpring-cage connection
Connection in acc. with standardIEC 60947-7-1
Maximum load current41 A (in case of a 10 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal current IN41 A
Nominal voltage UN1000 V
Connection methodScrew connection
Connection in acc. with standardIEC 60947-7-1
Maximum load current125 A (with 50 mm² conductor cross section)
Nominal current IN125 A
Nominal voltage UN1000 V
Open side panelNo
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width16.2 mm
Length86 mm
Height NS 35/7,546.8 mm
Height NS 35/1554.3 mm

Connection data

Connection methodSpring-cage connection
Connection in acc. with standardIEC 60947-7-1
Stripping length12 mm
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.10 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.8
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.6 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible10
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.6 mm²
Conductor cross section flexible, with TWIN ferrule min.0.5 mm²
Conductor cross section flexible, with TWIN ferrule max.1.5 mm²
Internal cylindrical gageA5
Connection methodScrew connection
Connection in acc. with standardIEC 60947-7-1
Screw threadM6
Tightening torque, min3.2 Nm
Tightening torque max3.7 Nm
Stripping length18 mm
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.50 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.1/0
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.35 mm²
Min. AWG conductor cross section, flexible16
Max. AWG conductor cross section, flexible2
Conductor cross section flexible, with ferrule without plastic sleeve min.1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.35 mm²
Conductor cross section flexible, with TWIN ferrule min.1.5 mm²
Conductor cross section flexible, with TWIN ferrule max.10 mm²
2 conductors with same cross section, solid min.1.5 mm²
2 conductors with same cross section, solid max.16 mm²
2 conductors with same cross section, stranded min.1.5 mm²
2 conductors with same cross section, stranded max.10 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.10 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.10 mm²

Standards and Regulations

Connection in acc. with standardUL
IEC 60947-7-1
IEC 60947-7-1
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 3033210 Terminal blocks (EC000897)
Feature Name Feature Value
Rated current In (EF008250) 41 A
Rated voltage (EF000228) 1000 V
Type of electrical connection 1 (EF002526) Spring clamp connection
Type of electrical connection 2 (EF002527) Screw connection
Number of levels (EF002659) 1
Number of clamp positions per level (EF002660) 5
Suitable for conductor material (EF012572) Aluminium/copper
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Width (EF000008) 16.2 mm
Height (EF000040) 86 mm
Depth (EF000049) 46.8 mm
Closing plate required (EF002525) No
Colour (EF000007) Blue
Internally connected stages (EF002661) Yes

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.