RBO 10-3L/N-HC 3076099 PHOENIX CONTACT Bolt connection terminal block, Connection method: Bolt connection, C.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RBO 10-3L/N-HC 3076099 PHOENIX CONTACT Bolt connection terminal block, Connection method: Bolt connection, C..

RBO 10-3L/N-HC

3076099

PHOENIX_CONTACT

2

Bolt connection terminal block, Connection method: Bolt connection, Cross section: 6 mm²

More details


Enclosures connectivity

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



General

Number of levels1
Number of connections8
Nominal cross section150 mm²
Colorgray/blue
Insulating materialPA
Flammability rating according to UL 94V0

General

Rated surge voltage8 kV
Pollution degree3
Overvoltage categoryIII
Insulating material groupI
Connection in acc. with standardIEC 60947-7-1
Maximum load current309 A (with 150 mm² conductor cross section)
Nominal current IN309 A
Nominal voltage UN1500 V
Open side panelnein

Dimensions

Width164 mm
Length235 mm
Height NS 35/7,582 mm
Height NS 35/1589.5 mm

Connection data

NoteConnection bolts
Connection methodBolt connection
Connection in acc. with standardIEC 60947-7-1
Conductor cross section solid min.6 mm²
Conductor cross section solid max.150 mm²
Conductor cross section AWG min.10
Conductor cross section AWG max.300
Conductor cross section flexible min.6 mm²
Conductor cross section flexible max.150 mm²
Min. AWG conductor cross section, flexible10
Max. AWG conductor cross section, flexible300
Cable lug connection according to standardDIN 46 234
Min. cross section for cable lug connection6 mm²
Max. cross section for cable lug connection150 mm²
Hole diameter10.5 mm
Width30 mm
Bolt diameter10 mm
Screw threadM10
Tightening torque, min10 Nm
Tightening torque max20 Nm
Cable lug connection according to standardDIN 46,235
Min. cross section for cable lug connection16 mm²
Max. cross section for cable lug connection150 mm²
Hole diameter10.5 mm
Width34 mm
Bolt diameter10 mm
Screw threadM10
Tightening torque, min10 Nm
Tightening torque max20 Nm
Screw threadM10
Tightening torque, min10 Nm
Tightening torque max20 Nm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.