MACX MCR-SL-RTD-I-SP-NC 2924320 PHOENIX CONTACT Temperature measuring transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-SL-RTD-I-SP-NC 2924320 PHOENIX CONTACT Temperature measuring transducer

MACX MCR-SL-RTD-I-SP-NC

2924320

PHOENIX_CONTACT

Temperature measuring transducer

Temperature transducer, converts signals from resistance temperature detectors and resistors into 0/4 - 20 mA analog signals. Freely programmable, 3-way electrical isolation. Replacement item: 1050201 MACX MCR-RTD-I-SP.

More details


INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeTemperature transmitter
ApplicationTemperature
TypeSignal conditioner
Insulation characteristics
Overvoltage categoryII
Pollution degree2

Electrical properties
Alignment span± 5 %
Alignment zero± 5 %
Electrical isolation3-way isolation
Step response (0–99%)700 ms
≤ 1100 ms
Temperature coefficient, typical0.01 %/K
Electrical isolation Input/output/power supply
Rated insulation voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1
Electrical isolation Input/output
Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)
Electrical isolation Input/power supply
Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)
Supply
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption< 40 mA (24 V DC)
Power dissipation< 1 W

Input data
Signal
Number of inputs1
Input signalTemperature
Resistor
Measurement
Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Temperature measuring range-200 °C ... 850 °C (Range depending on the sensor type)
Linear resistance measuring range0 Ω ... 2000 Ω
Max. permissible overall conductor resistance50 Ω (Per cable)
Sensor input current200 µA ... 1 mA
Temperature measuring range> 50 K

Output data
Switching:
Configurable/programmableno
Signal
Output descriptionCurrent output
Number of outputs1
Configurable/programmableYes
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output≤ 500 Ω
Output ripple (current)< 50 µAPP
< 10 µArms
Behavior in the event of a sensor errorAs per NE 43 or can be freely defined

Connection data
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16

Signaling
Status displayLED supply voltage, PWR (green)
Red LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR)
Red LED, flashing 1.2 Hz (service operation, ERR)
Red LED, permanently on (module error, ERR)

Dimensions
Dimensional drawingpxkryaccbd.jpg
Width12.5 mm
Height116 mm
Depth114.5 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing materialPA 6.6-FR

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (not assessed by UL)
Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

Approvals
CE
CertificateCE-compliant
Noteand EN 61326-1
ATEX
Identification II 3G Ex nA ic IIC T4 Gc X
UL, USA/Canada
IdentificationUL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
CertificateGL 86 644-10HH
GL
IdentificationC, EMC1

EMC data
Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Noise emissionEN 61000-6-4
Electromagnetic HF field
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Fast transients (burst)
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Conducted interference
DesignationConducted interferences
Standards/regulationsEN 61000-4-6

Standards and regulations
Electrical isolation3-way isolation

Mounting
Mounting typeDIN rail mounting

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.