VAL-MS 230/FM 2839130 PHOENIX CONTACT Surge voltage arrester consisting of base element with remote indicato.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS 230/FM 2839130 PHOENIX CONTACT Surge voltage arrester consisting of base element with remote indicato..

VAL-MS 230/FM

2839130

PHOENIX_CONTACT

Available

Ship on today

Surge voltage arrester consisting of base element with remote indicator contact and ground connector with high-capacity varistor, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 1-channel

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+57,40 €
4+53,90 €
7+52,85 €
10+52,27 €
14+51,82 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height97 mm
Width17.6 mm
Depth58 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

Standards/specificationsIEC 61643-11 2011
EN 61643-11 2012
IEC test classificationII
T2
EN typeT2
IEC power supply systemTN
TT
Number of portsOne
SPD designVoltage-limiting type
Mode of protectionL-PEN
L-N
Mounting typeDIN rail: 35 mm
Colorjet black RAL 9005
Housing materialPA 6.6
PBT
Pollution degree2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions1
Surge protection fault messageOptical, remote indicator contact

Protective circuit

Nominal voltage UN240/415 V AC (TN)
240/415 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC275 V AC
Rated load current IL80 A
Residual current IPE≤ 0.45 mA
Standby power consumption PC≤ 120 mVA
Nominal discharge current In (8/20) µs20 kA
Maximum discharge current Imax (8/20) µs40 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 1.35 kV
Residual voltage Ures≤ 1.35 kV (at In)
≤ 1.1 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3 kA)
TOV behavior at UT335 V AC (5 s / withstand mode)
440 V AC (120 min / safe failure mode)
Response time tA≤ 25 ns
Max. backup fuse with branch wiring125 A AC (gG)
Max. backup fuse with V-type through wiring80 A AC (gG)

Indicator/remote signaling

Connection nameRemote fault indicator contact
Switching functionPDT contact
Operating voltage5 V AC ... 250 V AC
30 V DC
Operating current5 mA AC ... 1 A AC
1 A DC
Connection methodScrew connection
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG28 ... 16

Connection data

Connection methodScrew connection
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.35 mm²
Conductor cross section AWG15 ... 2
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-N)275 V AC
Nom. voltage230 V AC
Mode of protectionL-N
Power distribution system1
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-N)1900 V
Nominal discharge current In (L-N)20 kA

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2839130-VAL-MS 230/FMEnglish128 KbytesPHOENIX CONTACT-2839130-VAL-MS 230/FM

Reviews (0)