Product successfully added to your shopping cart
PT 3-HF-12DC-ST
2858043
PHOENIX_CONTACT
1
Surge protection plug
Trabtech (TT)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2858043 |
---|---|
Packing unit | 10 pc |
Catalog page | Page 145 (C-4-2017) |
GTIN | 4017918878047 |
Weight per Piece (excluding packing) | 20.470 g |
Custom tariff number | 85363090 |
Country of origin | DE (Germany) |
Height | 45 mm |
---|---|
Width | 17.7 mm |
Depth | 52 mm |
Horizontal pitch | 1 Div. |
Complete module height | 90 mm |
Complete module width | 17.7 mm |
Complete module depth | 65.5 mm |
Ambient temperature (operation) | -40 °C ... 85 °C |
---|---|
Altitude | max. 2000 m |
Degree of protection | IP20 |
Housing material | PA |
---|---|
Flammability rating according to UL 94 | V-0 |
Color | black |
Standards for cearances and creepage distances | DIN EN 61664-1 |
IEC 60664-1 | |
Mounting type | on base element |
Type | Male |
Number of positions | 3 |
Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
Arrester can be tested with CHECKMASTER from software version: | From SW rev. 1.10 |
IEC test classification | C1 |
---|---|
C2 | |
C3 | |
D1 | |
VDE requirement class | C1 |
C2 | |
C3 | |
D1 | |
Nominal voltage UN | 12 V DC |
Maximum continuous voltage UC | 14 V DC |
9.8 V AC | |
Rated current | 450 mA (45°C) |
Operating effective current ICat UC | ≤ 5 µA |
Residual current IPE | < 5 µA (with PT 1X2-BE) |
< 1 µA (with PT 1X2+F-BE) | |
Nominal discharge current In(8/20) µs (line-line) | 10 kA |
Nominal discharge current In(8/20) µs (line-earth) | 10 kA |
Nominal discharge current In(8/20) µs (core-signal ground) | 10 kA |
Pulse discharge current Iimp(10/350) µs | 2.5 kA |
Total discharge current Itotal(8/20) µs | 20 kA |
Max. discharge current Imax(8/20) µs maximum (line-line) | 10 kA |
Max. discharge current Imax(8/20) µs maximum (line-earth) | 10 kA |
Nominal pulse current Ian (10/1000) µs (line-line) | 67 A |
Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 55 V |
Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 55 V (with PT 1X2-BE) |
≤ 700 V (with PT 1X2+F-BE) | |
Output voltage limitation at 1 kV/µs (line-line) static | ≤ 25 V |
Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 25 V |
≤ 40 V (with PT 1X2+F-BE) | |
Residual voltage at In(line-line) | ≤ 25 V |
Residual voltage at In(line-earth) | ≤ 40 V (with PT 1X2-BE) |
Residual voltage at In(line-signalground) | ≤ 25 V (with PT 1X2-BE) |
Residual voltage with Ian (10/1000) µs (line-line) | ≤ 25 V |
Residual voltage with Ian (10/1000) µs (line-signalground) | ≤ 25 V |
Voltage protection level Up(line-line) | ≤ 50 V (C3 - 25 A) |
≤ 80 V (C1 - 1 kV/500 A) | |
≤ 110 V (C2 - 10 kV / 5 kA) | |
≤ 80 V (6 kV / 3 kA) | |
Voltage protection level Up(line-earth) | ≤ 50 V (C3 - 25 A) |
≤ 85 V (C1 - 1 kV/500 A) | |
≤ 140 V (C2 - 10 kV / 5 kA) | |
≤ 100 V (6 kV / 3 kA) | |
Voltage protection level Up(line-signalground) | ≤ 50 V (C3 - 25 A) |
Response time tA(line-line) | ≤ 500 ns |
Response time tA(line-earth) | ≤ 500 ns |
Input attenuation aE, sym. | typ. 0.3 dB (≤ 5 MHz / 100 Ω) |
Cut-off frequency fg (3 dB), sym. in 100 Ohm system | typ. 60 MHz |
Capacity (line-line) | typ. 30 pF |
Resistance in series | 2.2 Ω ±10 % (7-8/11-12) |
Max. required back-up fuse | 500 mA (T) |
Impulse durability (line-line) | C2 - 10 kV/5 kA |
C3 - 67 A | |
Impulse durability (line-earth) | C2 - 10 kV/5 kA |
C3 - 67 A | |
D1 - 2.5 kA |
Connection method | Screw connection (in connection with the base element) |
---|---|
Screw thread | M3 |
Tightening torque | 0.8 Nm |
Stripping length | 8 mm |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Stripping length | 8 mm |
---|---|
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2858043-PT 3-HF-12DC-ST | 305 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.