Product successfully added to your shopping cart
CT 10-9VA-230AC
2830498
PHOENIX_CONTACT
1
Surge protection plug
Trabtech (TT)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2830498 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 105 (C-6-2013) |
GTIN | 4017918106553 |
Weight per Piece (excluding packing) | 112.400 g |
Custom tariff number | 85363010 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -40 °C ... 85 °C |
---|---|
Altitude | ≤ 2000 mm (amsl (above mean sea level)) |
Degree of protection | IP20 |
Housing material | PBT |
---|---|
Flammability rating according to UL 94 | V-0 |
Color | jet black RAL 9005 |
Standards for cearances and creepage distances | VDE 0110-1 |
IEC 60664 | |
Mounting type | On CT-TERMIBLOCK and LSA-PLUS disconnect strip |
Type | LSA-PLUS module |
Direction of action | Line-Line & Line-Earth Ground |
Arrester can be tested with CHECKMASTER from software version: | From SW rev. 1.00 |
IEC test classification | C1 |
---|---|
C3 | |
Nominal voltage UN | 250 V DC |
230 V AC | |
Maximum continuous voltage UC | 275 V DC |
275 V AC | |
Rated current | 1.5 A AC (per path) |
200 mA DC (per path) | |
Operating effective current ICat UC | ≤ 1.5 mA AC (per path) |
≤ 2 mA DC (per path) | |
Residual current IPE | ≤ 1 µA |
Nominal discharge current In(8/20) µs (line-earth) | 1.5 kA |
Nominal discharge current In(8/20) µs (core-signal ground) | 1.5 kA |
Nominal discharge current In(8/20) µs (signalground-earth) | 5 kA |
Total discharge current Itotal(8/20) µs | 5 kA |
Max. discharge current Imax(8/20) µs maximum (line-earth) | 5 kA (10-PE) |
Max. discharge current Imax(8/20) µs maximum (line-signalground) | 3 kA |
Residual voltage at In(line-earth) | ≤ 1.4 kV |
Residual voltage at In(line-signalground) | ≤ 1.1 kV |
Fixed cable length | 10 m |
Voltage protection level Up(line-earth) | ≤ 1.4 kV (10-PE) |
Voltage protection level Up(line-signalground) | ≤ 1.1 kV |
Response time tA(line-line) | ≤ 25 ns |
Response time tA (line-signalground) | ≤ 25 ns |
Response time tA(line-earth) | ≤ 100 ns |
Frequency range | 50 Hz ... 60 Hz |
Capacity (line-signalground) | typ. 320 pF |
Capacity (line-earth) | typ. 2 pF (10-PE) |
Surge protection fault message | none |
Max. required back-up fuse | 1.5 A AC (gL) |
200 mA DC (F) | |
Impulse durability (line-earth) | C2 - 3 kV/1.5 kA |
Impulse durability (line-signalground) | C2 - 3 kV/1.5 kA |
Impulse durability (signalground-earth) | C2 - 10 kV/5 kA |
Connection method | can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips |
---|---|
Connection method IN | COMTRAB plug-in system |
Connection method OUT | COMTRAB plug-in system |
Standards/specifications | IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 |
---|---|
EN 61643-21 2001 + A1:2009 + A2:2013 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2830498-CT 10-9VA-230AC | 151 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.