CT 10-9VA-230AC 2830498 PHOENIX CONTACT LSA-PLUS plug (COMTRAB CT 10) with surge protection incl. visual fau.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CT 10-9VA-230AC 2830498 PHOENIX CONTACT LSA-PLUS plug (COMTRAB CT 10) with surge protection incl. visual fau..

CT 10-9VA-230AC

2830498

PHOENIX_CONTACT

Available

Ship on today

LSA-PLUS plug (COMTRAB CT 10) with surge protection incl. visual fault warning for nine 2-core signal circuits. Nominal voltage: 230 V AC. Design: 10 double wires

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for information technology - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$388.67
2+$374.73
3+$368.21
4+$364.25
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height22 mm
Width111 mm
Depth68.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPBT
Flammability rating according to UL 94V2
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664
Mounting typeOn CT-TERMIBLOCK and LSA-PLUS disconnect strip
TypeLSA-PLUS module
Direction of actionLine-Line & Line-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00

Protective circuit

IEC test classificationC1
C3
Nominal voltage UN230 V AC
Maximum continuous voltage UC275 V DC
275 V AC
Maximum continuous voltage UC (wire-ground)275 V DC
275 V AC
Maximum continuous voltage UC (wire-GND)275 V DC
275 V AC
Nominal current IN1.5 A
Operating effective current IC at UC≤ 1.5 mA
≤ 2 mA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (Core-Earth)1.5 kA
Nominal discharge current In (8/20) µs (Core-GND)1.5 kA
Nominal discharge current In (8/20) µs (GND-Ground)5 kA
Total surge current (8/20) µs5 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)5 kA (10-PE)
Max. discharge current Imax (8/20) µs maximum (Core-GND)4.5 kA (10)
Residual voltage at In (conductor-ground)≤ 1.4 kV
Residual voltage at In (conductor-GND)≤ 1.1 kV
Fixed cable length10 m
Enery absorption, asymmetrical71 J
Voltage protection level Up (core-ground)≤ 1.4 kV (10-PE)
Voltage protection level Up (core-GND)≤ 1.1 kV (10)
Response time tA (Core-Core)≤ 25 ns
Response time tA (Core-Earth)≤ 25 ns
≤ 100 ns
Frequency range50 Hz ... 60 Hz
Capacity (Core-GND)320 pF (10)
Capacity (Core-Earth)2 pF (10-PE)
Surge protection fault messageoptical
Max. required back-up fuse1.5 A (gL)

Connection data

Connection methodcan be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Connection type INCOMTRAB plug-in system
Connection type OUTCOMTRAB plug-in system

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2830498-CT 10-9VA-230AC English 151 Kbytes PHOENIX CONTACT-2830498-CT 10-9VA-230AC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.