CT 10-18FSR+F/PE-24 2807939 PHOENIX CONTACT Surge protection plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CT 10-18FSR+F/PE-24 2807939 PHOENIX CONTACT Surge protection plug

CT 10-18FSR+F/PE-24

2807939

PHOENIX_CONTACT

Surge protection plug

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $831.23
Unit price: $831.23

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2807939
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 107 (C-6-2013)
GTIN4017918075415
Weight per Piece (excluding packing)1.330 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height22 mm
Width111 mm
Depth68.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 75 °C
Degree of protectionIP20

General

Housing materialPBT
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
Mounting typeOn CT-TERMIBLOCK and LSA-PLUS disconnect strip
TypeLSA-PLUS module
Direction of actionLine-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN24 V DC
Maximum continuous voltage UC40 V DC
28 V AC
Rated current140 mA (25 °C)
Operating effective current ICat UC≤ 5 µA (18x)
Residual current IPE≤ 1 µA
Nominal discharge current In(8/20) µs (line-line)5 kA
Nominal discharge current In(8/20) µs (line-earth)5 kA
Total discharge current Itotal(8/20) µs10 kA
Max. discharge current Imax(8/20) µs5 kA
Max. discharge current Imax(8/20) µs maximum (line-earth)
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 60 V (a, b)
Output voltage limitation at 1 kV/µs (line-earth) static≤ 650 V
Residual voltage at In(line-line)≤ 85 V (a-b)
Residual voltage at In(line-signalground)≤ 85 V
Response time tA(line-line)≤ 1 ns (a-b)
Response time tA(line-earth)≤ 100 ns (a, b)
Input attenuation aE, sym.1.8 dB (Typ. up to 1 MHz / 50 Ω)
0.6 dB (Typ. up to 400 kHz / 150 Ω)
0.2 dB (Typ. up to 60 kHz / 600 Ω)
Input attenuation aE, asym.
Cut-off frequency fg (3 dB), sym. in 50 Ohm system6 MHz (typ.)
Cut-off frequency fg (3 dB), sym. in 150 Ohm system2.5 MHz (typ.)
Cut-off frequency fg (3 dB), sym. in 600 Ohm system750 kHz (typ.)
Capacity (line-earth)1.1 nF (1 MHz a ... b)
Resistance in series22 Ω ±10 %
Surge protection fault messagenone
Max. required back-up fuse145 mA
Impulse durability (line-earth)D1 - 2.5 kA
Impulse durability (signalground-earth)D1 - 2.5 kA

Connection data

Connection methodcan be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Connection method INCOMTRAB plug-in system
Connection method OUTCOMTRAB plug-in system

Standards and Regulations

Standards/regulationsIEC 61643-21
Standards/specificationsIEC 61643-21 2000

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.