VAL-MS 75 VF ST 2805318 PHOENIX CONTACT Surge protection plug type 2 with series connection consisting of va.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS 75 VF ST 2805318 PHOENIX CONTACT Surge protection plug type 2 with series connection consisting of va..

VAL-MS 75 VF ST

2805318

PHOENIX_CONTACT

10

Available

Ship on today

Surge protection plug type 2 with series connection consisting of varistor and gas-filled spark gap for VAL-MS base element, thermal monitoring, visual fault warning.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$50.98
20+$50.02
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height52.4 mm
Width17.5 mm
Depth55.3 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g
Vibration (operation)5g

General

Standards/specificationsIEC 61643-11 2011
EN 61643-11 2012
IEC test classificationII
T2
EN typeT2
SPD designCombination type
Mode of protectionL-PE
Mounting typeOn base element
Colorblack
Housing materialPA 6.6
Pollution degree2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions1
Surge protection fault messageoptical

Additional descriptions

NoteThe values specified for the L-L protective path are only valid in connection with VAL-MS/2+0-BE/FM/S2

Protective circuit

Nominal voltage UN5 V AC ... 48 V AC
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC75 V AC
Residual current IPE≤ 5 µA
Standby power consumption PC≤ 1 mVA
Nominal discharge current In (8/20) µs10 kA
Nominal discharge current In (8/20) µs (L-L)10 kA
Maximum discharge current Imax (8/20) µs20 kA
Maximum discharge current Imax (8/20) µs (L-L)20 kA
Short-circuit current rating ISCCR10 kA
Voltage protection level Up≤ 1.4 kV
Voltage protection level Up (L-L)≤ 1.8 kV
Residual voltage Ures≤ 0.45 kV (at In)
≤ 0.35 kV (at 5 kA)
≤ 0.3 kV (at 3 kA)
Residual voltage Ures (L-L)≤ 0.9 kV (at In)
≤ 0.7 kV (at 5 kA)
≤ 0.6 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.4 kV
Front of wave sparkover voltage at 6 kV (1.2/50) µs (L-L)≤ 1.8 kV
Response time tA≤ 100 ns
Response time tA (L-L)≤ 100 ns
Max. backup fuse with branch wiring63 A AC (gG)

Connection data

Connection methodVALVETRAB plug-in system

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2805318-VAL-MS 75 VF ST English 111 Kbytes PHOENIX CONTACT-2805318-VAL-MS 75 VF ST

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.