Product successfully added to your shopping cart
VAL-MS 580/3+0-FM
2920447
PHOENIX_CONTACT
1
Type 2 surge arrester
Trabtech (TT)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2920447 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 41 (C-6-2015) |
GTIN | 4046356163569 |
Weight per Piece (excluding packing) | 386.100 g |
Custom tariff number | 85363030 |
Country of origin | DE (Germany) |
Degree of protection | IP20 (only when all terminal points are used) |
---|---|
Ambient temperature (operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
IEC test classification | II |
---|---|
T2 | |
EN type | T2 |
IEC power supply system | TN-C |
IT | |
Mode of protection | L-PE |
L-PEN | |
Mounting type | DIN rail: 35 mm |
Color | jet black RAL 9005 |
Housing material | PA 6.6 |
PBT | |
Degree of pollution | 2 |
Distance between live and grounded parts | 5 mm |
Flammability rating according to UL 94 | V-0 |
Type | DIN rail module, two-section, divisible |
Number of positions | 3 |
Surge protection fault message | Optical, remote indicator contact |
Note | For use in all low-voltage systems between L-PEN. Only for use in IT systems between L-PE if the bodies of the equipment in the low-voltage system are connected to the grounding system of the transformer station. (common grounding of the HV transformer station and the bodies of the LV consumer's installation. RE= RAaccording to IEC 60364-4-442/VDE 0100-442 Figure 44D/example a) |
---|
Nominal voltage UN | 400/690 V AC (TN-C) |
---|---|
500 V AC (IT) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 580 V AC |
Rated load current IL | 80 A |
Residual current IPE | ≤ 0.75 mA |
Standby power consumption PC | ≤ 450 mVA |
Nominal discharge current In(8/20) µs | 15 kA |
Maximum discharge current Imax(8/20) µs | 30 kA |
Short-circuit current rating ISCCR | 25 kA |
Voltage protection level Up | ≤ 2.5 kV |
Residual voltage Ures | ≤ 2.5 kV (at In) |
≤ 2.3 kV (at 10 kA) | |
≤ 2.1 kV (at 5 kA) | |
≤ 1.9 kV (at 3 kA) | |
TOV behavior at UT | 690 V AC (5 s / withstand mode) |
762 V AC (120 min / withstand mode) | |
Response time tA | ≤ 25 ns |
Max. backup fuse with V-type through wiring | 80 A (gG) |
Max. backup fuse with branch wiring | 125 A (gG) |
Switching function | PDT contact |
---|---|
Operating voltage | 5 V AC ... 250 V AC |
30 V DC | |
Operating current | 5 mA AC ... 1.5 A AC |
1 A DC | |
Connection method | Plug-in/screw connection via COMBICON |
Screw thread | M2 |
Tightening torque | 0.25 Nm |
Stripping length | 7 mm |
Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Connection method | Screw connection |
---|---|
Screw thread | M5 |
Tightening torque | 3 Nm (1,5 mm² ... 16 mm²) |
4.5 Nm (25 mm² ... 35 mm²) | |
Stripping length | 16 mm |
Conductor cross section flexible | 1.5 mm² ... 25 mm² |
Conductor cross section solid | 1.5 mm² ... 35 mm² |
Conductor cross section AWG | 15 ... 2 |
Connection method | Fork-type cable lug |
Conductor cross section flexible | 1.5 mm² ... 16 mm² |
SPD Type | 4CA |
---|---|
Maximum continuous operating voltage MCOV (L-L) | 1160 V AC |
Maximum continuous operating voltage MCOV (L-G) | 580 V AC |
Nom. voltage | 400/690 V AC |
Mode of protection | L-L |
L-G | |
Power distribution system | Delta |
Nominal frequency | 50/60 Hz |
Measured limiting voltage MLV (L-L) | 4270 V |
Measured limiting voltage MLV (L-G) | 2310 V |
Nominal discharge current In(L-L) | 10 kA |
Nominal discharge current In(L-G) | 10 kA |
Operating voltage | 125 V AC |
---|---|
Operating current | 1 A AC |
Tightening torque | 4 lbf-in. |
Conductor cross section AWG | 30 ... 14 |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2920447-VAL-MS 580/3+0-FM | 239 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.