ELR 3- 24DC/500AC- 2 2297196 PHOENIX CONTACT Three-phase solid-state contactor with 24 V DC input, 2 A outpu.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELR 3- 24DC/500AC- 2 2297196 PHOENIX CONTACT Three-phase solid-state contactor with 24 V DC input, 2 A outpu..

ELR 3- 24DC/500AC- 2

2297196

PHOENIX_CONTACT

Three-phase solid-state contactor with 24 V DC input, 2 A output current, zero voltage switch, optionally with thermal fuse.

More details


INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Dimensions

Width40 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Degree of protectionIP20

Input data

Input nameDevice supply
Protective circuitProtection against polarity reversal Suppressor diode
Surge protection
Status displayYellow LED
IndicationRed LED
Input nameControl input right/left
Rated actuating voltage UC24 V DC
Voltage range with reference to UC0.8 ... 1.25
Rated actuating current IC8.3 mA
Switching threshold9.6 V (“0” signal)
19.2 V (“1” signal)

Output data

Output nameAC output
Nominal output voltage500 V AC
Nominal output voltage range48 V AC ... 575 V AC
Periodic peak reverse voltage1200 V
Mains frequency50 Hz
60 Hz
Rated operating current at AC-512 A
Rated operating current at AC-53a2 A
Leakage current6 mA
Residual voltage< 1.5 V
Surge current200 A (t = 10 ms)
Max. load value250 A2s
Type of protectionRCV circuit
Surge voltage protection> 575 V AC

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

General

Test voltage input/output5 kVrms
Switching frequency≤ 10 Hz
Mounting positionVertical (horizontal DIN rail)
Assembly instructionsCan be aligned with spacing = 20 mm
Operating mode100% operating factor
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
InsulationBasic insulation
Pollution degree2
Overvoltage categoryIII
DesignationStandards/regulations
Standards/regulationsEN 60947

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.