ANUNCIAR
SACCBP-FS-5CON-PG9/1,0-920SCO 1437533 PHOENIX CONTACT Bus system flush-type socket View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SACCBP-FS-5CON-PG9/1,0-920SCO 1437533 PHOENIX CONTACT Bus system flush-type socket

SACCBP-FS-5CON-PG9/1,0-920SCO

1437533

PHOENIX_CONTACT

Bus system flush-type socket

Conect. plug. to be apar. wall poster., CANopen®, DeviceNet™, 5-pole, halogen-free PUR, lilac red RAL 4001, shielded, Connection female, straight, M12-SPEEDCON, coding: A, to free cable end, Rear mounting, Cable connection, cable length: 1 m, CANopen®/DeviceNet™, PUR, violet, Alternative product according to RoHS II without exception 6c (Pb< 0.1%) item code: 1239659

Device connector rear mounting, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded, Socket, straight, M12-SPEEDCON, coding: A, on free cable end, Rear mounting, Cable connection, cable length: 1 m, CANopen®/DeviceNet™, PUR, violet, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239659

More details


Connectors > Circular connector, mounting (with cable)

Field Device Connectors (FDC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $62.69
Unit price: $62.69
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

Notes
Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Order information:Lock nut is included in the scope of delivery
Safety note
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Mounting
Mounting typeRear mounting

Product properties
Product typeCircular connectors (device side)
Sensor typeCANopen®
Number of positions5
No. of cable outlets1
Shieldedyes
CodingA
Thread typeM12
Data management status
Article revision13
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFKM
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Outer sheath, materialPUR

Electrical properties
Rated surge voltage1.5 kV
Insulation resistance100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Transmission mediumCopper

Connection data
Conductor connection
Connection methodCable connection
Contact connection typeSocket
Tightening torque2 Nm ... 3 Nm (Installation-side)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles> 100

Connector
Connection 1
Head designSocket
Head cable outletstraight
Head thread typeM12
Head locking typeSPEEDCON
CodingA
Connection 2
Head designfree cable end

Cable/line
Cable length1 m
CANopen®/DeviceNet™, PUR, violet [920]
Dimensional drawingrhrjzbepqc.jpg
Cable weight90 kg/km
UL AWM Style21198 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™, PUR, violet [920]
Conductor structure2xAWG24/19+2xAWG22/19
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter6.70 mm ±0.3 mm
Outer sheath, materialPUR
External sheath, colorred lilac RAL 4001
Conductor materialTin-plated Cu litz wires
Material wire insulationFoamed PE (Data cable)
PE (Power supply)
Single wire, colorred-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering80 %
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance120 Ω ±10 % (with 1 MHz)
Cable capacitynom. 40 nF/km (Data cable)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation67 mm
Dynamic load capacity (bending)Max. bending cycles: 5000000, Bending radius: 70 mm, Bending radius: 10 x D, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: -20 °C ... 60 °C
Shield attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistanceUL 1581, Section 1060 and UL 2556, Section 9.3 (FT1)
UL 1581, Section 1100 and UL 2556, Section 9.1 (HFT/FT2)
IEC 60332-1-2
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
-20 °C ... 60 °C (for installation)
-20 °C ... 60 °C (cable, drag chain applications)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67 (When plugged in)
IP65 (When plugged in)
IP65/IP67
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

ETIM for 1437533 Connectors (EC003570)
Feature Name Feature Value
Cable length (EF000536) 1 mm
Type of plug-in contact, outer side (EF005528) None
Mounting method (EF000003) Back wall mounting
Housing material (EF001596) Other
Material of contact surface (EF004020) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Ambient temperature (EF002386) 85 °C
Operating temperature (EF002393) -25 °C
Rated voltage (EF000228) 48 V
With shield connection (EF002535) Yes
Screw-in thread (EF012303) M12
Min. number of insertion cycles (EF012212) 100
Degree of protection (IP), mounted (EF007466) Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.