Product successfully added to your shopping cart
MNT-TV-SAT D/WH
2882297
PHOENIX_CONTACT
1
Socket attachment plug with surge protection for the power supply unit and signal connection for radio and television equipment (cable, terrestrial antenna, satellite system). Cable is provided.
Surge protected power outlet adapter for power supply and connection of radio and TV signals (cable, terrestrial antenna, satellite installation). The cable is included.
Trabtech (TT)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| General | |
| Note | Shielding requirements according to DIN EN 50083-2, Class A |
| Product type | Device protection |
| Product family | MAINTRAB |
| IEC test classification | C2 |
| C3 | |
| D1 | |
| IEC power supply system | TN |
| TT | |
| Type | Attachment plug |
| Number of positions | 2 |
| For country-specific use in | D, A, NL, E, S, FIN, TR |
| Surge protection fault message | optical |
| Data management status | |
| Article revision | 12 |
| Insulation characteristics | |
| Overvoltage category | II |
| Pollution degree | 2 |
| IEC test classification | III |
| T3 | |
| EN type | T3 |
| Number of ports | One |
| Connection method | F connector |
| Connection method | Grounding plug/socket |
| Dimensional drawing | ![]() |
| Width | 63 mm |
| Height | 107 mm |
| Depth | 78 mm |
| Color | white (RAL 9010) |
| black (RAL 9005) | |
| Flammability rating according to UL 94 | V-0 |
| CTI value of material | 400 |
| 600 | |
| Insulating material | PA 6 |
| Housing material | PA 6 |
| Power supplies | |
| Direction of action | L/N-PE & Signal Line-Shield-Earth Ground |
| Nominal voltage UN | 230/400 V AC (TN/TT) |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous operating voltage UC(L-N) | 275 V AC |
| Maximum continuous operating voltage UC(L-PE) | 360 V AC |
| Maximum continuous operating voltage UC(N-PE) | 360 V AC |
| Rated load current IL | 16 A (30 °C) |
| Residual current IPE | ≤ 5 µA |
| Standby power consumption PC | ≤ 1 VA |
| Reference test voltage UREF | 255 V AC |
| Combination wave UOC | 6 kV |
| Voltage protection level Up | ≤ 1.5 kV |
| TOV behavior at UT(L-N) | 460 V AC (5 s / withstand mode) |
| 460 V AC (120 min / safe failure mode) | |
| TOV behavior at UT(L-PE) | 460 V AC (5 s / withstand mode) |
| 460 V AC (120 min / withstand mode) | |
| 1455 V AC (200 ms / safe failure mode) | |
| TOV behavior at UT(N-PE) | 1200 V AC (200 ms / safe failure mode) |
| Response time tA(L-N) | ≤ 25 ns |
| Response time tA(L-PE) | ≤ 100 ns |
| Response time tA(N-PE) | ≤ 100 ns |
| Max. required back-up fuse | 16 A (gG / B / C) |
| Short-circuit current rating ISCCR | 1.5 kA AC |
| Information technology | |
| Maximum continuous voltage UC | 24 V DC |
| Rated current | 1.5 A (25 °C) |
| Operating effective current ICat UC | ≤ 1 µA |
| Standby power consumption PC | ≤ 1 VA |
| Residual current IPE | ≤ 1 µA |
| Insulation resistance Riso | ≥ 70 MΩ |
| ≥ 70 MΩ | |
| Nominal discharge current In(8/20) µs (line-ground) | 2.5 kA |
| Nominal discharge current In(8/20) µs (line-shield) | 2.5 kA |
| Nominal discharge current In(8/20) µs (shield-ground) | 5 kA |
| Total discharge current Itotal(8/20) µs | 5 kA |
| Nominal pulse current Ian (10/1000) µs (line-shield) | 120 A |
| Nominal pulse current Ian (10/1000) µs (shield-ground) | 200 A |
| Output voltage limitation at 1 kV/µs (line-shield) spike | ≤ 700 V |
| Output voltage limitation at 1 kV/µs (shield-ground) spike | ≤ 1 kV |
| Output voltage limitation at 1 kV/µs (line-shield) static | ≤ 700 V |
| Output voltage limitation at 1 kV/µs(shield-ground) static | ≤ 1 kV |
| Residual voltage at In(conductor-shield) | ≤ 40 V |
| Residual voltage at In(shield-ground) | ≤ 50 V |
| Voltage protection level Up(line-shield) | ≤ 700 V (C2 - 2 kA) |
| Voltage protection level Up(shield-ground) | ≤ 1.2 kV (C2 - 5 kA) |
| Response time tA (line-shield) | ≤ 100 ns |
| Response time tA (shield-ground) | ≤ 100 ns |
| Input attenuation aE, asym. | typ. 0.3 dB (≤ 2.4 GHz /75 Ω) |
| Cut-off frequency fg (3 dB), asym. (shield) in 75 Ω system | typ. 2.5 GHz |
| Frequency range | 0 Hz ... 2400 MHz |
| Capacity asymmetrical (shield) | typ. 10 pF |
| Alternating current carrying capacity (line-shield) | 5 A - 1 s |
| Alternating current carrying capacity (shield-ground) | 10 A - 1 s |
| Pulse reset time (line-shield) | ≤ 4 s |
| Ambient conditions | |
| Degree of protection | IP20 (Child-proofing) |
| Ambient temperature (operation) | -25 °C ... 75 °C |
| Ambient temperature (storage/transport) | -25 °C ... 75 °C |
| Altitude | ≤ 2000 m (amsl) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Standards/specifications | IEC 61643-11 |
| Note | 2011 |
| Standards/specifications | EN 61643-11 |
| Note | 2019 |
| Standards/specifications | EN 61643-21 |
| Note | A2:2013 |
| Standards/specifications | IEC 61643-21 |
| Note | A2:2012 |
| Standards/specifications | EN 50083 |
| Note | CLASS-A |
| Mounting type | Plugging into the mains socket |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX PROTECTION EN .pdf | 27 Mbytes |
|
| PHOENIX CONTACT-2882297-MNT-TV-SAT D/WH | 113 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.