MNT-TELE S/WH 2880901 PHOENIX CONTACT Type 3 surge protection device View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MNT-TELE S/WH 2880901 PHOENIX CONTACT Type 3 surge protection device

MNT-TELE S/WH

2880901

PHOENIX_CONTACT

Type 3 surge protection device

Socket attachment plug with surge protection for the power supply and signal connection of an end device with analog or digital telecommunications interface (VDSL up to 50 Mbps, on short paths (< 300 m) up to 80 Mbps). Cable is included.

More details


Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeDevice protection
Product familyMAINTRAB
IEC test classificationC1
C2
C3
D1
TypeAttachment plug
For country-specific use inNL, E, I, S, FIN, TR
Surge protection fault messageoptical
Wire pairs per module1
Insulation characteristics
Overvoltage categoryIII
Pollution degree2
EN typeT3
Number of portsOne

Connection data
Connection methodRJ12
Connection methodGrounding plug/socket

Dimensions
Dimensional drawingtrqxlvhfvf.jpg
Width63 mm
Height103 mm
Depth78 mm

Material specifications
Flammability rating according to UL 94V-0
CTI value of material400
600
Insulating materialPA 6
Housing materialPA 6

Protective circuit
Power supplies
Direction of actionL/N-PE & Signal Line-Earth Ground
Nominal voltage UN230/400 V AC (TN)
230/400 V AC (TT - only in use with RCD)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC(L-N)275 V AC
Maximum continuous operating voltage UC(L-PE)360 V AC
Maximum continuous operating voltage UC(N-PE)360 V AC
Rated load current IL16 A (30 °C)
Residual current IPE≤ 5 µA
Standby power consumption PC≤ 1 VA
Reference test voltage UREF255 V AC
Nominal discharge current In(8/20) µs3 kA (> 5x)
Combination wave UOC4 kV
Energy absorption symmetrical140 J (L-N)
Enery absorption, asymmetrical220 J (L(N)-PE)
Voltage protection level Up(L-N)≤ 1.2 kV
Voltage protection level Up(L-PE)≤ 1.5 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Residual voltage at Iamax, (L-N)≤ 1 kV (at 1 kA)
≤ 1.2 kV (at UOC)
Residual voltage at Iamax, (L-PE)≤ 1 kV (at 1 kA)
≤ 1.5 kV (at UOC)
Residual voltage at Iamax, (PE)≤ 1 kV (at 1 kA)
≤ 1.5 kV (at UOC)
TOV behavior at UT(L-N)335 V AC (5 s / withstand mode)
440 V AC (120 min / safe failure mode)
TOV behavior at UT(L-PE)440 V AC (5 s / withstand mode)
440 V AC (120 min / withstand mode)
1455 V AC (200 ms / safe failure mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / safe failure mode)
Response time tA(L-N)≤ 25 ns
Response time tA(L-PE)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
Max. required back-up fuse16 A (gG / B / C)
Short-circuit current rating ISCCR1.5 kA AC
Max. backup fuse with branch wiring16 A (gG / B / C)
Information technology
Maximum continuous voltage UC200 V DC
Rated current150 mA (25 °C)
Operating effective current ICat UC≤ 150 µA
Standby power consumption PC≤ 1 VA
Residual current IPE≤ 2 µA
Insulation resistance Riso≥ 1 MΩ
≥ 1 GΩ
Nominal discharge current In(8/20) µs (line-line)1 kA
Nominal discharge current In(8/20) µs (line-ground)2.5 kA
Total discharge current Itotal(8/20) µs10 kA
Max. discharge current Imax(8/20) µs2.5 kA
Nominal pulse current Ian (10/1000) µs (line-line)35 A
Nominal pulse current Ian (10/1000) µs (line-earth)200 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 360 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 900 V
Output voltage limitation at 1 kV/µs (line-line) static≤ 360 V
Residual voltage at In(conductor-conductor)≤ 500 V
Residual voltage at In(conductor-ground)≤ 30 V
Residual voltage with Ian (10/1000) µs (line-line)≤ 35 V
Residual voltage with Ian (10/1000) µs (line-earth)≤ 35 V
Voltage protection level Up(line-line)≤ 460 V (C2 - 1 kA)
≤ 350 V (C3 - 25 A)
Voltage protection level Up(line-earth)≤ 900 V (C2 - 2 kA)
≤ 900 V (C3 - 100 A)
Response time tA(line-line)≤ 25 ns
Response time tA(line-earth)≤ 100 ns
Cut-off frequency fg (3 dB), sym. in 100 Ω systemtyp. 4 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 3 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ω systemtyp. 700 kHz
Capacity (Core-Core)typ. 1 nF
Capacity (Core-Earth)typ. 5 pF
Alternating current carrying capacity (line-line)250 mA - 1 s
Alternating current carrying capacity (line-earth)10 A - 1 s
Pulse reset time (line-line)≤ 15 ms

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (Child-proofing)
Ambient temperature (operation)-25 °C ... 75 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Standards and regulations
Standards/specificationsIEC 61643-11
Note2011
Standards/specificationsEN 61643-11
Note2012
Standards/specificationsEN 61643-21
NoteA2:2013
Standards/specificationsIEC 61643-21
NoteA2:2012

Mounting
Mounting typePlugging into the mains socket

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.