SACB-6Q/4P-L-SC 1662942 PHOENIX CONTACT Sensor/actuator box View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SACB-6Q/4P-L-SC 1662942 PHOENIX CONTACT Sensor/actuator box

SACB-6Q/4P-L-SC

1662942

PHOENIX_CONTACT

Sensor/actuator box

More details


Sensors > Passive sensor-actuator interface (with cable)

QUICKON Installation System (QPD)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey1662942
Packing unit1 pc
Catalog pagePage 273 (C-2-2017)
GTIN4017918137496
Weight per Piece (excluding packing)218.900 g
Custom tariff number85366990
Country of originPL (Poland)

General

Rated voltage24 V DC
Max. operating voltage Umax30 V DC
Current carrying capacity per I/O signal4 A
Current carrying capacity per slot4 A
Total rated current12 A
Number of positions4
Number of slots6
Flammability rating according to UL 94V0
Sensor/actuator connection systemQUICKON

Ambient conditions

Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 60 °C

Local diagnostics function

Local diagnosticsSupply voltage per module Green LED
Status display I/O Yellow LED

Master cable data/connection data

Connection methodSpring-cage connection
Conductor cross section min. (signal)0.14 mm²
Conductor cross section max. (signal)1 mm²
Conductor cross section AWG min. (signal)26
Conductor cross section AWG max. (signal)17
Stripping length (signal)10 mm
Conductor cross section min. (energy)0.2 mm²
Conductor cross section max. (energy)1.5 mm²
Conductor cross section AWG min. (energy)24
Conductor cross section AWG max. (energy)16
External cable diameter min.6.5 mm
External cable diameter max.9.5 mm
Stripping length70 mm (Master cable)
Tightening torque, union nut2.5 Nm

Conductor data

Structure of individual litz in acc. with VDE 0295 / smallest wire diameterClass 2-6 // 0.34 mm²: 0.1 mm; 0.5 - 0.75 mm²: 0.15 mm
Wire insulation materialPVC / PE
Wire diameter including insulation≤ 2.5 mm
Minimum external conductor diameter4 mm
Maximum external conductor diameter7.5 mm
Tightening torque, union nut2.5 Nm
Wrench size, union nut22 mm
Note on the frequency of connectionsif the conductor is connected more than once, seal and cap may need to be replaced.
Conductor cross section flexible min.0.34 mm²
Conductor cross section flexible max.0.75 mm²
Conductor cross section AWG min.22
Conductor cross section AWG max.18

Insulation material

Housing materialPA
Material of the moulding massPUR
Contact materialSteel/copper
Contact surface materialSn
Contact carrier materialPA 6.6
Material of contact, master cable sideCuZn
Material of contact surface, master cable sideNiSn
Material of the contact carrier on the master cable sidePA 6.6 V0

Pin assignment

Slot/position = Wire color or connection1 / 4 (A) = 1 / 4
2 / 4 (A) = 2 / 4
3 / 4 (A) = 3 / 4
4 / 4 (A) = 4 / 4
5 / 4 (A) = 5 / 4
6 / 4 (A) = 6 / 4
1-6 / 1 (+ 24 V) = UN
1-6 / 3 (0 V) = 0 V
1-6 / 5 (PE) = PE

Standards and Regulations

Connection in acc. with standardCUL
Flammability rating according to UL 94V0

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.