ANUNCIAR
RIF-2-RPT-LDP-24DC/4X21/EX 2909741 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RIF-2-RPT-LDP-24DC/4X21/EX 2909741 PHOENIX CONTACT Relay Module

RIF-2-RPT-LDP-24DC/4X21/EX

2909741

PHOENIX_CONTACT

Relay Module

Pre-assembled relay module consisting of: relay socket, function insertable module, relay with power contact and clamping flange approved according to ATEX/IECEx (zone 2) and Ex zone class I, div. 2, Push-in connection, 4 inverter contacts, Free flow diode, Input voltage: 24 VDC

More details


Relays > Switching relay

Industrial Relays

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $35.09
Unit price: $35.09
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2909741
Packing unit10 pc
NoteMade to Order (non-returnable)
GTIN4055626379913
Weight per Piece (excluding packing)109.630 g
Custom tariff number85364110
Country of originCN (China)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width31 mm
Height96 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Input voltage range in reference to UNsee diagram
Typical input current at UN42 mA
Typical response time13 ms
Typical release time14 ms
Coil voltage24 V DC
Protective circuitDamping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition1.01 W

Contact side

Contact type4 PDTs
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (At 24 mA)
Min. switching current5 mA (at 24 V)
Maximum inrush current16 A (20 ms, N/O contact)
Limiting continuous current6 A (see diagram)
Interrupting rating (ohmic load) max.144 W (at 24 V DC)
124 W (at 48 V DC)
108 W (at 60 V DC)
52 W (at 110 V DC)
48 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.22 A (at 120 V, DC13)
0.11 A (at 250 V, DC13)
1.5 A (at 24 V, AC15)
1.5 A (at 120 V, AC15)
1 A (at 240 V, AC15)

General

Test voltage relay winding/relay contact2.5 kVrms(50 Hz, 1 min.)
Test voltage relay contact/relay contact2 kVrms(50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay base)
RT III (Relay)
Mechanical service lifeapprox. 2x 107cycles
ATEX II 3G Ex ec nC IIC T4 Gc
EU-type examination certificateIBExU17ATEXB014X
IECExEx ec nC IIC T4 Gc
IECEx certificateIECEx IBE 17.0032X
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

Connection data output side

Connection nameContact side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

Standards and Regulations

Standards/regulationsDIN EN 50178
IEC 61508-1
Rated insulation voltage250 V AC
Rated surge voltage2.5 kV
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryIII
DesignationEx zone
Standards/regulationsEN/IEC 60079-0
EN/IEC 60079-7
EN/IEC 60079-15
Flammability rating according to UL 94V2
ATEX II 3G Ex ec nC IIC T4 Gc
IECExEx ec nC IIC T4 Gc
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.