VAL-MS-T1/T2 1000DC-PV-ST 2801162 PHOENIX CONTACT Replacement plug for PV arrester combinations from the VAL.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 1000DC-PV-ST 2801162 PHOENIX CONTACT Replacement plug for PV arrester combinations from the VAL..

VAL-MS-T1/T2 1000DC-PV-ST

2801162

PHOENIX_CONTACT

Available

Ship on today

Replacement plug for PV arrester combinations from the VAL-MS-T1/T2 1000DC-PV-... product range

More details


Programmable Logic Controllers Plcs

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+44,22 €
5+40,97 €
9+40,12 €
13+39,66 €
18+39,31 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height52.4 mm
Width17.5 mm
Depth55.3 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)60g (Half sine/11 ms/3x XYZ)
Vibration (operation)7.5g (5-500 Hz/2.5 h/XYZ)

General

Standards/specificationsEN 50539-11 2013
IEC test classificationPV T1
PV T2
SPD failure behaviorOCM (Open-circuit mode)
SPD designVoltage-limiting type
Installation locationInside
AccessibilityAccessible
Installation location of the disconnect deviceInternal
Mounting typeOn base element
Colorjet black RAL 9005
Housing materialPA 6.6-FR
Pollution degree2
Flammability rating according to UL 94V-0
Surge protection fault messageoptical

Protective circuit DC voltage side (DC)

Maximum continuous operating voltage UCPV525 V DC
Open circuit voltage UOCSTC≤ 435 V DC
Short-circuit current rating ISCPV1000 A
Continuous operating current ICPV< 20 µA
Standby power consumption PC≤ 25 mVA
Nominal discharge current (8/20) µs15 kA
Maximum discharge current Imax (8/20) µs40 kA
Impulse discharge current (10/350)˽µs, charge2.5 As
Impulse discharge current (10/350)˽µs, specific energy6.25 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp5 kA
Residual voltage Ures≤ 1.8 kV (at In)
≤ 1.5 kV (at 5 kA)
≤ 1.7 kV (at 10 kA)
≤ 1.9 kV (at 20 kA)
≤ 2.2 kV (at 30 kA)
≤ 2.4 kV (at 40 kA)
Response time tA≤ 25 ns
Insulation resistance Riso> 5 GΩ (at 500 V DC)

UL specifications

SPD Type4 (for Type 2 photovoltaic applications)
Maximum continuous operating voltage MCOV (L-G)1050 V DC
Nom. voltage875 V AC
Mode of protectionL-G
Power distribution system1
Voltage protection rating VPR (L-G)3 kV
Nominal discharge current In (L-G)20 kA

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2801162-VAL-MS-T1/T2 1000DC-PV-STEnglish113 KbytesPHOENIX CONTACT-2801162-VAL-MS-T1/T2 1000DC-PV-ST

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review