Key Commercial Data

Orderkey2964063
Packing unit10 pc
Catalog pagePage 439 (C-5-2017)
GTIN4017918099374
Weight per Piece (excluding packing)22.900 g
Custom tariff number85364190
Country of originCN (China)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height80 mm
Depth56 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

Coil side

Nominal input voltage UN24 V AC/DC
Input voltage range in reference to UN0.8 ... 1.1
Typical input current at UN6.5 mA
Typical response time5 ms
Typical release time15 ms
Protective circuitBridge rectifier Bridge rectifier
Operating voltage displayYellow LED
Power dissipation for nominal condition0.16 W

Contact side

Contact type1 N/O contact
Type of switch contactDouble contact
Contact materialAgNi, hard gold-plated
Maximum switching voltage250 V AC
125 V DC
Minimum switching voltage0.1 V
Min. switching current1 mA
Maximum inrush current5 A
Limiting continuous current3 A (5 A up to 35°C at 24 V DC)
Interrupting rating (ohmic load) max.72 W (at 24 V DC)
60 W (at 48 V DC)
50 W (at 60 V DC)
50 W (at 110 V DC)
750 VA (for 250 V AC)
120 W (at 24 V DC - up to 35°)

General

Type of noteNote on application
NoteUse of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.
Test voltage relay winding/relay contact2 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Mechanical service lifeapprox. 2x 107cycles
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)22.9 g

Connection data input side

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm

Connection data output side

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm

Standards and Regulations

Connection in acc. with standardCUL
Standards/regulationsIEC 60664
EN 50178
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryIII

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.