EMG 22-REL/KSR- 24/21AU 2947721 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMG 22-REL/KSR- 24/21AU 2947721 PHOENIX CONTACT Relay Module

EMG 22-REL/KSR- 24/21AU

2947721

PHOENIX_CONTACT

10

Relay Module

More details


Industrial Relays

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey2947721
Packing unit10 pc
NoteMade to Order (non-returnable)
Catalog pagePage 135 (IF-2011)
GTIN4017918082840
Weight per Piece (excluding packing)63.350 g
Custom tariff number85364190
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width22.5 mm
Height75 mm
Depth62.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

Coil side

Nominal input voltage UN24 V AC/DC
Input voltage range in reference to UN0.8 ... 1.1
Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Protective circuitBridge rectifier Bridge rectifier
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W

Contact side

Contact typeSingle contact, 1-PDT
Type of switch contactSingle contact
Contact materialAgNi, hard gold-plated
Maximum switching voltage30 V AC
36 V DC
Maximum inrush current50 mA
Limiting continuous current50 mA
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)

Contact side (with destroyed gold layer)

Notethe following values are applicable if a gold layer is destroyed
Maximum switching voltage250 V AC/DC
Limiting continuous current6 A
Maximum inrush current8 A
Interrupting rating (ohmic load) max.144 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
1500 VA (for 250 V AC)

General

Test voltage relay winding/relay contact5 kVrms(50 Hz, 1 min.)
Test voltage relay contact/relay contact1 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20
Mechanical service lifeapprox. 3x 107cycles
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)63.35 g

Connection data input side

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Connection data output side

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Standards and Regulations

Standards/regulationsEN 50178
Rated insulation voltage260 V AC
InsulationBasic insulation
Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
Degree of pollution2
Overvoltage categoryIII

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.