Protective plug PT with protective circuit for higher signal voltages, 2-channel, visual fault warning. Nominal voltage: 60 V AC

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$79.65
20+$79.48
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height45 mm
Width17.7 mm
Depth52 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesIEC 60664-1
Mounting typeOn base element
TypeDIN rail module, two-section, divisible
Direction of actionLine-Line & Line-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN60 V AC
Maximum continuous voltage UC100 V DC
75 V AC (50/60 Hz)
Nominal current IN26 A AC (30 °C)
3 A DC
Operating effective current IC at UC≤ 1.5 mA AC (per path)
≤ 2 mA DC (per path)
Residual current IPE≤ 3 mA AC
≤ 4 mA DC
Nominal discharge current In (8/20) µs (Core-Earth)2 kA
Impulse discharge current (10/350)˽µs, peak value limp500 A (per path)
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 200 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 200 V
Enery absorption, asymmetrical40 J
Voltage protection level Up (core-ground)≤ 300 V (C2 - 4 kV/2 kA)
≤ 220 V (C3 - 100 A)
≤ 250 V (C1 - 1.4 kV / 0.7 kA)
Response time tA (Core-Earth)≤ 25 ns
Input attenuation aE, asym.typ. 0.3 dB (≤ 150 kHz / 150 Ω)
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm systemtyp. 600 kHz
Capacity (Core-GND)typ. 4 nF
Surge protection fault messageOptical, remote indicator contact
Max. required back-up fuse25 A AC (gL/gG)
3 A DC (T)
Impulse durability (conductor-ground)C1 (1,4 kV / 0,7 kA)
C2 - 4 kV/2 kA
C3 (100 A)
D1 (500 A)

Connection data

Connection methodScrew connection (in connection with the base element)
Connection type INPLUGTRAB plug-in system
Connection type OUTPLUGTRAB plug-in system
Screw threadM3
Tightening torque0.8 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2839172-PT 2X1VA- 60AC-ST English 117 Kbytes PHOENIX CONTACT-2839172-PT 2X1VA- 60AC-ST

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.