IL PN BK DI8 DO4 2SCRJ-PAC 2878379 PHOENIX CONTACT PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IL PN BK DI8 DO4 2SCRJ-PAC 2878379 PHOENIX CONTACT PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V ..

IL PN BK DI8 DO4 2SCRJ-PAC

2878379

PHOENIX_CONTACT

Available

Ship on today

PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V DC, 500 mA, complete with I/O connectors

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

Software

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$789.81
2+$775.67
3+$766.62
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Product description

The bus coupler for the PROFINET protocol has 4 digital outputs and 8 digital inputs. This package contains all the necessary Inline plugs for connecting the supply and the I/Os.

The Inline terminals can be labeled using pull-out labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the ZBFM-6... Zack marker strip for labeling the terminal points.

Dimensions

Width80 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsSpecfications with connectors

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)80 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Interfaces

Fieldbus systemPROFINET
DesignationPROFINET
Connection methodSC-RJ socket
Wavelength660 nm
Transmission speed100 MBit/s (acc. to PROFINET standard)
Fieldbus systemLokalbus
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s / 2 MBit/s (Automatic detection, no combined system)

Digital inputs

Input nameDigital inputs
Connection methodInline connector
2, 3-wire
Number of inputs8 (EN 61131-2 type 1)
Typical response timeapprox. 500 µs
Protective circuitProtection against polarity reversal Suppressor diode
Filter time3 ms
Input characteristic curveIEC 61131-2 type 1
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA
Typical input current per channeltyp. 3 mA
Delay at signal change from 0 to 15 ms
Delay at signal change from 1 to 05 ms

Digital outputs

Output nameDigital outputs
Connection methodInline connector
2, 3-wire
Number of outputs4
Protective circuitShort-circuit and overload protection Free running circuit
Output voltage24 V DC -1 V (At nominal current)
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block2 A
Maximum output current per module2 A
Nominal load, inductive12 VA (1.2 H; 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W

Power supply for module electronics

Connection methodSpring-cage connection
DesignationBus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 250 mA (from UBK)
Power losstyp. 3 W (entire device)
Communications power UL7.5 V DC
Current consumption0.8 A
Power consumptiontyp. 1.7 W

General

Net weight367.9 g
Note on weight specificationswith connectors
Mounting typeDIN rail mounting
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes

Inline potentials

Communications power UL7.5 V DC ±5 %
Power supply at ULmax. 0.8 A DC
Main circuit supply UM24 V DC
Supply voltage range UM19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UMmax. 8 A DC (Sum of UM + US; 4 A, maximum, when used in potentially explosive areas.)
Current consumption from UMmax. 8 A DC
Segment supply voltage US24 V DC
Supply voltage range US19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at USmax. 8 A DC (Sum of UM + US; 4 A, maximum, when used in potentially explosive areas.)
Current consumption from USmax. 8 A DC
I/O supply voltage UANA24 V DC
Supply voltage range UANA19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UANAmax. 0.5 A DC

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2878379-IL PN BK DI8 DO4 2SCRJ-PAC English 143 Kbytes PHOENIX CONTACT-2878379-IL PN BK DI8 DO4 2SCRJ-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.