QUINT-PS/1AC/24DC/ 5 2866750 PHOENIX CONTACT Power supply unit View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

QUINT-PS/1AC/24DC/ 5 2866750 PHOENIX CONTACT Power supply unit

QUINT-PS/1AC/24DC/ 5

2866750

PHOENIX_CONTACT

Power supply unit

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $322.00
Unit price: $322.00

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey2866750
Packing unit1 pc
Catalog pagePage 158 (C-6-2015)
GTIN4046356113786
Weight per Piece (excluding packing)1,022.000 g
Custom tariff number85044030
Country of originTH (Thailand)

Dimensions

Width40 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly43 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height5000 m

Input data

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC
90 V DC ... 350 V DC
Dielectric strength maximum300 V AC
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Discharge current to PE< 3.5 mA
Current consumption1.2 A (120 V AC)
0.6 A (230 V AC)
1.3 A (110 V DC)
0.6 A (220 V DC)
Nominal power consumption145 VA
Inrush surge current< 15 A
Mains buffering> 55 ms (120 V AC)
> 55 ms (230 V AC)
Input fuse5 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (AC: Characteristics B, C, D, K)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)5 A (-25 °C ... 60 °C, UOUT= 24 V DC)
POWER BOOST (IBoost)7.5 A (-25°C ... 40°C permanent, UOUT= 24 V DC )
Selective Fuse Breaking (ISFB)30 A (12 ms)
Derating60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistancemax. 35 V DC
Output overvoltage protection< 35 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 40 mVPP(with nominal values)
Output power120 W
Typical response time< 0.15 s
Maximum power dissipation in no-load condition3 W
Power loss nominal load max.15 W

General

Net weight0.7 kg
Efficiency> 90 % (for 230 V AC and nominal values)
Insulation voltage input/output4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE3.5 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE500 V DC (routine test)
Protection classI
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 1134000 h (25 °C)
> 635000 h (40 °C)
> 270000 h (60 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Connection data for signaling

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.12
Screw threadM3

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCSA
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m (Test Level 2)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-6-3
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Equipment safetyBG (design tested)
Standard - Approval for medical useIEC 60601-1, 2 x MOOP
Shipbuilding approvalDNV GL (EMC A), ABS, LR, RINA, NK, BV
UL approvalsUL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
DeviceNet approvalDeviceNet™ Power Supply Conformance Tested
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Approval - requirement of the semiconductor industry with regard to mains voltage dipsSEMI F47-0706 Compliance Certificate
Information technology equipment - safety (CB scheme)IEC 60950-1 (2ndEdition)
Rail applicationsEN 50121-4
Overvoltage category (EN 62477-1)III

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.