FLT-CP-PLUS-3S-350 2882640 PHOENIX CONTACT Combination type 1/2 protective device View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FLT-CP-PLUS-3S-350 2882640 PHOENIX CONTACT Combination type 1/2 protective device

FLT-CP-PLUS-3S-350

2882640

PHOENIX_CONTACT

Combination type 1/2 protective device

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: FLT-SEC-P-T1-3S-350/25-FM 2905421

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2882640
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 28 (C-6-2013)
GTIN4046356098243
Weight per Piece (excluding packing)1,394.700 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height95 mm
Width142.4 mm
Depth71.5 mm
Horizontal pitch8 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (5 - 500 Hz/2.5 h/X, Y, Z)

General

IEC test classificationI / II
T1 / T2
EN typeT1 / T2
IEC power supply systemTN-S
TT
Mode of protectionL-N
L-PE
N-PE
Mounting typeDIN rail: 35 mm
Colorgray/blue
black
Housing materialPBT
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions4
Surge protection fault messageOptical, remote indicator contact

Protective circuit

Nominal voltage UN240/415 V AC (TN-S)
240/415 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC(L-N)350 V AC
Maximum continuous voltage UC(N-PE)350 V AC
Rated load current IL125 A (< 55 °C)
Residual current IPE≤ 0.01 mA
Nominal discharge current In(8/20) µs (L-N)25 kA
Nominal discharge current In(8/20) µs (L-PE)25 kA
Nominal discharge current In(8/20) µs (N-PE)100 kA
Maximum discharge current Imax(8/20) µs (L-N)50 kA
Maximum discharge current Imax(8/20) µs (L-PE)50 kA
Impulse discharge current (10/350) µs (L-N), charge12.5 As
Impulse discharge current (10/350) µs (L-N), specific energy160 kJ/Ω
Impulse discharge current (10/350) µs (L-N), peak current value Iimp25 kA
Impulse discharge current (10/350) µs (L-PE), charge12.5 As
Impulse discharge current (10/350) µs (L-PE), specific energy160 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp25 kA
Impulse discharge current (10/350) µs (N-PE), charge50 As
Impulse discharge current (10/350) µs (N-PE), specific energy2500 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp100 kA
Total discharge current Itotal(10/350) µs100 kA
Follow current interrupt rating Ifi(L-N)50 kA
Follow current interrupt rating Ifi(N-PE)100 A
Short-circuit current rating ISCCR50 kA
Voltage protection level Up(L-N)≤ 1.5 kV
Voltage protection level Up(L-PE)≤ 2.5 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Residual voltage Ures(L-N)≤ 1.5 kV (at In)
Residual voltage Ures(L-PE)≤ 2.5 kV (at In)
Residual voltage Ures(N-PE)≤ 1.5 kV (at In)
TOV behavior at UT(L-N)415 V AC (5 s / withstand mode)
457 V AC (120 min / withstand mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Response time tA(L-N)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
Max. backup fuse with V-type through wiring125 A (gG)
Max. backup fuse with branch wiring315 A (gG)

Indicator/remote signaling

Switching functionPDT contact
Operating voltage12 V AC ... 250 V AC
125 V DC (200 mA DC)
Operating current10 mA AC ... 1 A AC
1 A DC (30 V DC)
Connection methodPlug-in/screw connection via COMBICON
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Connection data

Connection methodScrew terminal blocks
Screw threadM5
Tightening torque4.5 Nm
Stripping length18 mm
Conductor cross section flexible2.5 mm² ... 25 mm²
Conductor cross section solid2.5 mm² ... 35 mm²
Conductor cross section AWG13 ... 2

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-L)528 V AC
Maximum continuous operating voltage MCOV (L-N)264 V AC
Maximum continuous operating voltage MCOV (L-G)528 V AC
Maximum continuous operating voltage MCOV (N-G)264 V AC
Nom. voltage240/415 V AC
Mode of protectionL-L
L-N
L-G
N-G
Power distribution systemWye
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-L)2450 V
Measured limiting voltage MLV (L-N)1350 V
Measured limiting voltage MLV (L-G)1570 V
Measured limiting voltage MLV (N-G)1080 V
Nominal discharge current In(L-L)20 kA
Nominal discharge current In(L-N)20 kA
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(N-G)20 kA

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.