SACCBP-MS-12CON-M16/1,0-PVCSCO
1442227
PHOENIX_CONTACT
1
Flush-type connector
Conect. plug. to be apar. poster wall, Universal, 12-pole, PVC/PVC, black RAL 9005, shielded, Male connector, straight, M12-SPEEDCON, coding: A, at free cable end, Rear mounting, M16 x 1.5, Cable connection, cable length: 1 m, 0.14 mm², Black PVC, Alternative product according to RoHS II without exception 6c (Pb< 0.1%) item code: 1239767
Device connector rear mounting, Universal, 12-position, PVC/PVC, black RAL 9005, shielded, Pin, straight, M12-SPEEDCON, coding: A, on free cable end, Rear mounting, M16 x 1.5, Cable connection, cable length: 1 m, 0.14 mm2, PVC black, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239767
Connectors > Circular connector, mounting (with cable)
Field Device Connectors (FDC)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Order information: | Lock nut is included in the scope of delivery |
| Safety note | |
| Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. | |
| • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. | |
| • The products are suitable for applications in plant, controller, and electrical device engineering. | |
| • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. | |
| • Assembled products may not be manipulated or improperly opened. | |
| • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). | |
| • When using the product in direct connection with third-party manufacturers, the user is responsible. | |
| • For operating voltages > 50 V AC, conductive connector housings must be grounded | |
| • Ensure that the protective or functional ground has been properly connected. | |
| • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector | |
| • Only use tools recommended by Phoenix Contact | |
| • The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product. | |
| • Operate the connector only when it is fully plugged in and interlocked. | |
| • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. | |
| • Observe the minimum bending radius of the cable. Lay the cable without twisting it. | |
| • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). | |
| Product type | Signal and power cable |
| Sensor type | Universal |
| Number of positions | 12 |
| No. of cable outlets | 1 |
| Shielded | yes |
| Coding | A |
| Thread type | M12 |
| Data management status | |
| Article revision | 08 |
| Insulation characteristics | |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Ambient conditions | |
| Degree of protection | IP67 (When plugged in) |
| IP65 (When plugged in) | |
| IP65/IP67 | |
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
| -40 °C ... 85 °C (without mechanical actuation) | |
| -25 °C ... 85 °C (Cable, flexible installation) | |
| -40 °C ... 85 °C (cable, fixed installation) | |
| Resistance to oil | in accordance with DIN EN 60811-404 |
| Connection 1 | |
| Head design | Pin |
| Head cable outlet | straight |
| Head thread type | M12 |
| Head locking type | SPEEDCON |
| Coding | A |
| Connection 2 | |
| Head design | free cable end |
| Rated surge voltage | 0.8 kV |
| Contact resistance | ≤ 3 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Nominal voltage UN | 30 V |
| Nominal current IN | 1.5 A |
| Max. conductor resistance | 142 Ω/km |
| Flammability rating according to UL 94 | V0 |
| Seal material | FKM |
| Contact material | CuZn |
| Contact surface material | Au |
| Contact carrier material | PA 6.6 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Outer sheath, material | PVC |
| Conductor material | Tin-plated Cu litz wires |
| Connection method | Cable connection |
| Tightening torque | 3 ... 4 Nm |
| Mounting type | Rear mounting M16 x 1.5 Thread with flat nut |
| Assembly note | Thread with flat nut |
| Flame resistance | IEC 60332-1-2, IEC 60332-1, FT1, VW-1 |
| Resistance to oil | in accordance with DIN EN 60811-404 |
| Other resistance | Hydrolysis and microbe resistant as per VDE 0282 section 10 |
| M12 | |
| Standard designation | M12 connector |
| Standards/specifications | IEC 61076-2-101 |
| Cable length | 1 m |
| Cable type | PVC black |
| Short symbol | PVC |
| Signal type/category | Universal |
| External cable diameter | 7.00 mm ±0.03 mm |
| Outer sheath, material | PVC |
| External sheath, color | black RAL 9005 |
| Wire diameter incl. insulation | 1 mm ±0.05 mm |
| Single wire, color | white-brown, green-yellow, gray-pink, blue-red, black-violet, gray/pink-red/blue |
| Cable cross section | 6x 2x 0.14 mm² |
| Material, inner sheath | PVC |
| Conductor material | Tin-plated Cu litz wires |
| Conductor structure signal line | 18x 0.10 mm |
| Material wire insulation | PVC |
| Thickness, insulation | 0.21 mm |
| Overall twist | Six pairs around the filler to the core |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 85 % |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 1500 V AC |
| Cable resistance | 142 Ω/km (at 20 °C) |
| Smallest bending radius, fixed installation | 42 mm |
| Smallest bending radius, movable installation | 105 mm |
| Resistance to oil | in accordance with DIN EN 60811-404 |
| Flame resistance | IEC 60332-1-2, IEC 60332-1, FT1, VW-1 |
| Other resistance | Hydrolysis and microbe resistant as per VDE 0282 section 10 |
| Ambient temperature (operation) | -40 °C ... 85 °C (cable, fixed installation) |
| -25 °C ... 85 °C (Cable, flexible installation) |
| Feature Name | Feature Value |
|---|---|
| Contact type (EF001587) | Other |
| Number of data contacts (EF012232) | 0 |
| Number of power contacts (EF012216) | 0 |
| Number of control contacts (EF012217) | 12 |
| Type of housing (EF006980) | Straight |
| Rated current In (EF008250) | 1.5 A |
| Ambient temperature (EF002386) | -25 °C |
| Rated voltage (EF000228) | 30 V |
| Over voltage category (EF006785) | II |
| Pollution degree (EF006786) | 3 |
| Material of contact surface (EF004020) | Gold |
| Housing material (EF001596) | Plastic |
| Material thread ring (EF012304) | Other |
| Type of locking (EF000208) | Other |
| Inflammability class of insulation material according to UL94 (EF002521) | V0 |
| With protective conductor (EF007468) | No |
| Degree of protection (IP), mounted (EF007466) | IP67 |
| Min. number of insertion cycles (EF012212) | 100 |
| Screened (EF000881) | Yes |
| With status indication (EF001602) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX CONNECTORS EN.pdf | 68 Mbytes |
|
| PHOENIX CONTACT-1442227-SACCBP-MS-12CON-M16/1,0-PVCSCO | 125 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.