PHOENIX CONTACT  PLC-OPT-48DC/230AC/1 2900370 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-OPT- 48DC/230AC/1 2900370 PHOENIX CONTACT PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal bloc..

Reference: PLC-OPT-48DC/230AC/1

Code: 2900370

Manufacturer: PHOENIX CONTACT

Description:

PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal block with push-in connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 48 V DC, output: 24 - 253 V AC/0.75 A
PLC-INTERFACE, consisting of PLC-BPT.../21 base terminal block with push-in connection and plug-in miniature solid-state relay, for installation on NS 35/7.5 rail, 1 closing contact, input: 48 V DC, output: 24-253 V AC/ 0.75 A

Categories:

  • Relays > Optocoupler
  • PHOENIX CONTACT > Industrial Relays

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 49,56 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C

Input data

Nominal input voltage UN48 V DC
Input voltage range in reference to UN0.8 ... 1.2
Switching threshold "0" signal in reference to UN≤ 0.25
Switching threshold "1" signal in reference to UN≥ 0.8
Typical input current at UN9 mA
Typical response time10 ms (at UN)
Typical turn-off time10 ms (at UN)
Operating voltage displayYellow LED
Type of protectionProtection against polarity reversal
Free-wheeling diode
Protective circuit/componentPolarity protection diode
Damping diode
Transmission frequency10 Hz

Output data

Output voltage range24 V AC ... 253 V AC
Limiting continuous current0.75 A (see derating curve)
Maximum inrush current30 A (10 ms)
Min. load current10 mA
Leakage current< 1 mA (in off state)
Max. load value4.5 A2s
Voltage drop at max. limiting continuous current< 1 V
Output circuit2-wire, floating
Type of protectionRCV circuit

Connection data, input side

Connection nameInput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kV (50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryIII

ETIM for 2900370 Relays (EC001504)

Feature nameInput voltage (EF003840)
Feature value38.4 V
Feature nameType of voltage (input voltage) (EF003033)
Feature valueDC
Feature nameOutput voltage (EF003933)
Feature value24 V
Feature nameType of output voltage (EF008222)
Feature valueAC
Feature nameRated operation current Ie (EF001443)
Feature value0.75 A
Feature nameType of digital output (EF003601)
Feature valueElectronic
Feature nameWith LED indication (EF005950)
Feature valueYes

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.