PLC-OPT- 24DC/230AC/2.4/ACT

2904632

PHOENIX_CONTACT

10

Available

Ship on today

PLC-INTERFACE for output functions, consisting of PLC-BPT…/ACT basic terminal block with push-in connection and integrated miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 24 - 253 V AC/2.4 A

More details


INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$39.28
20+$37.88
30+$37.22
40+$36.84
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width6.2 mm
Height80 mm
Depth86 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

"0" signal switching threshold in reference to UC< 0.4
"1" signal switching threshold in reference to UC> 0.8
Typical response time10 ms (at UC)
Typical turn-off time10 ms (at UC)
Status displayYellow LED
Type of protectionProtection against polarity reversal
Surge protection
Surge voltage protection> 33 V
Transmission frequency10 Hz

Output data

DesignationOutput data
Output voltage range24 V AC ... 253 V AC
Limiting continuous current2.4 A (see to derating)
Maximum inrush current250 A (20 ms)
Min. load current10 mA
Leakage current< 1 mA
Max. load value340 A2s (tp = 10 ms, at 25 °C)
Surge voltage protection> 275 V
Voltage drop at max. limiting continuous current< 1 V
Output circuit2-wire, zero voltage switch
Type of protectionRCV circuit

Connection data, input side

Connection nameInput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kV (50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage260 V AC
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2904632-PLC-OPT- 24DC/230AC/2.4/ACT English 116 Kbytes PHOENIX CONTACT-2904632-PLC-OPT- 24DC/230AC/2.4/ACT

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.