QUINT-UPS/ 24DC/ 24DC/10/3.4AH 2320267 PHOENIX CONTACT Uninterruptible power supply View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

QUINT-UPS/ 24DC/ 24DC/10/3.4AH 2320267 PHOENIX CONTACT Uninterruptible power supply

QUINT-UPS/ 24DC/ 24DC/10/3.4AH

2320267

PHOENIX_CONTACT

Uninterruptible power supply

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $502.61
Unit price: $502.61

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey2320267
Packing unit1 pc
Catalog pagePage 294 (C-4-2017)
GTIN4046356554183
Weight per Piece (excluding packing)4,434.000 g
Custom tariff number85371091
Country of originCN (China)

Dimensions

Width120 mm
Height169 mm
Depth125 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)0 °C ... 40 °C
Ambient temperature (storage/transport)-15 °C ... 40 °C
Max. permissible relative humidity (operation)≤ 95 % (25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2

Input data

Input voltage24 V DC
Input voltage range18 V DC ... 30 V DC
Current consumption (maximum)18.6 A (24 V DC)
Current consumption (idle)9.5 mA
Current consumption (charging process)3.6 A

Output data (24 V DC mains operation)

Nominal output voltage24 V DC
Output voltage range (depends on the input voltage)18 V DC ... 30 V DC
Nominal output current (IN)10 A (0 °C ... 40 °C)
POWER BOOST (IBoost)15 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB)60 A (0 °C ... 40 °C)

Output data (24 V DC battery operation)

Nominal output voltage24 V DC
Output voltage range (depends on the input voltage)19.2 V DC ... 27.6 V DC (UOUT= UBAT- 0.5 V DC)
Nominal output current (IN)10 A (0 °C ... 40 °C)
POWER BOOST (IBoost)15 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB)65 A (0 °C ... 40 °C)

General output data

Efficiency> 97.6 % (Mains operation, with charged energy storage)

General

IQ technologyYes
DisposalUsed batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations. They can also be returned to Phoenix Contact or the manufacturer.
Net weight3.8 kg
Memory mediumLead rechargeable battery module, 3.4 Ah
Protection classIII
MTBF (IEC 61709, SN 29500)> 806000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontal 5 mm, vertical 50 mm

Connection data, input

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4

Connection data, output

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4

Connection data for signaling

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM4

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m (Criterion A)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-6-3
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
EN 61558-2-17
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
UL approvalsUL/C-UL Recognized UL 60950-1
UL Listed UL 508
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g tv= 90 min.
Rail applicationsEN 50121-4

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 3
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.