Supervisory relay for 3-phase voltage monitoring of 483...897 V AC, undervoltage, Window, phase sequence, phase fault, asymmetry, selectable supply voltage via power module, 2 switched contacts

More details


Relays > Voltage monitoring relay

Industrial Relays

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $311.00
Unit price: $311.00
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2885249
Packing unit1 pc
Catalog pagePage 268 (C-5-2017)
GTIN4017918996482
Weight per Piece (excluding packing)277.100 g
Custom tariff number85364900
Country of originAT (Austria)

Dimensions

Width45 mm
Height90 mm
Depth113 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
-25 °C ... 40 °C (corresponds to UL 508)
Ambient temperature (storage/transport)-25 °C ... 70 °C

Input data

Nominal input voltage UN3 ~ 690 V
Maximum temperature coefficient< 0.1 %/K
FunctionUndervoltage, window, asymmetry, phase sequence, phase failure
Min. setting range-30 % ... 20 % (From UN)
Max. setting range-20 % ... 30 % (From UN)
Min setting range of the voltage threshold value483 V AC ... 828 V AC
Max. setting range of the voltage threshold value552 V AC ... 897 V AC
Setting range for response delay0.1 s ... 10 s
Basic accuracy± 5 % (of scale end value)
Setting accuracy≤ 5 % (of scale end value)
Repeat accuracy≤ 2 %
Asymmetry5 % ... 25% / OFF
Recovery time500 ms

Contact side

Contact type2 floating PDT contacts
Maximum switching voltage250 V AC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max.750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Output fuse5 A (fast-blow)

Power supply

Supply voltage range230 V AC ... 500 V AC (see Power modules)

General

Mechanical service lifeapprox. 2x 107cycles
Operating mode100% operating factor
Mounting positionany
Assembly instructionson standard DIN rail NS 35 in accordance with EN 60715
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Overvoltage categoryIII, basic insulation (as per EN 50178)
Housing insulation materialPolyamide PA, self-extinguishing
Colorgreen
Rated insulation voltage600 V (acc. to EN 50178)
ConformanceCE-compliant
UL, USA/CanadaUL/C-UL listed UL 508

Connection data

Conductor cross section flexible min.0.25 mm²
Conductor cross section flexible max.2.5 mm²
Connection methodScrew connection
Stripping length8 mm
Conductor cross section solid0.5 mm² ... 2.5 mm²
Conductor cross section flexible0.25 mm² ... 2.5 mm²
Conductor cross section AWG20 ... 14
Tightening torque1 Nm

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-3
Noise immunityEN 61000-6-2
Low Voltage DirectiveConformance with LV directive 2006/95/EC
ConformanceCE-compliant
UL, USA/CanadaUL/C-UL listed UL 508

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2885249 Relays (EC001438)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
Voltage measuring range 1 (EF006134) 483 V
Type of voltage measuring range (EF003399) AC
Single-phase under voltage possible (EF003390) No
Three-phase under voltage possible (EF003391) Yes
Single-phase over voltage possible (EF003392) No
Three-phase over voltage possible (EF003393) No
Single-phase hysteresis possible (EF003394) No
Three-phase hysteresis possible (EF003395) Yes
Contains function DC-under voltage (EF003396) No
Contains function DC-over voltage (EF003397) No
Contains function DC-voltage hysteresis (EF003398) No
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Width (EF000008) 45 mm
Height (EF000040) 90 mm
Depth (EF000049) 113 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.