Double-level modular terminal block with surge voltage coarse protection between both levels, disconnect knife in the upper level, nominal voltage: 60 V AC, for mounting on NS 32 or NS 35/7.5, closed housing, terminal width: 6.2 mm, terminal height: 68 mm

More details


Programmable Logic Controllers Plcs

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height68 mm
Width6.2 mm
Length80 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664
Mounting typeDIN rail/G-profile rail
TypeDouble-level terminal block with disconnect knife
Number of positions1
Direction of actionLine-Line

Protective circuit

IEC test classificationC1
C2
D1
VDE requirement classC2
Nominal voltage UN60 V AC
Maximum continuous voltage UC170 V DC
120 V AC
Maximum continuous voltage UC (wire-wire)120 V AC
170 V DC
Nominal current IN2 A (85 °C)
Operating effective current IC at UC≤ 2 µA
Nominal discharge current In (8/20) µs (Core-Core)5 kA
Total surge current (8/20) µs5 kA
Max. discharge current Imax (8/20) µs maximum (Core-Core)5 kA
Output voltage limitation at 1 kV/µs (Core-Core) spike≤ 650 V
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 650 V
Response time tA (Core-Core)≤ 100 ns
Capacity (Core-Core)≤ 2 pF
Max. required back-up fuse2 A
Impulse durability (conductor-conductor)C2 - 10 kV/5 kA
Alternating current carrying capacity (conductor-ground)2.5 A (1 s)

Connection data

Connection methodScrew connection
Connection type INScrew terminal blocks
Connection type OUTScrew terminal blocks
Screw threadM3
Tightening torque0.5 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF