TT-2/2-M-24DC 2920722 PHOENIX CONTACT Modular terminal block with two-stage surge protection for two signal .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

TT-2/2-M-24DC 2920722 PHOENIX CONTACT Modular terminal block with two-stage surge protection for two signal ..

TT-2/2-M-24DC

2920722

PHOENIX_CONTACT

14

Available

Ship on today

Modular terminal block with two-stage surge protection for two signal wires with common reference potential, disconnect knife on both signal paths, separate ground connection, nominal voltage: 24 V DC

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height94.8 mm
Width6.2 mm
Depth69.1 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C

General

Housing materialPA 6.6
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Mounting typeDIN rail: 35 mm
TypeDouble-level terminal block with PE foot – separate PE connection
Number of positions2
Direction of actionLine-Earth Ground

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN24 V DC
Maximum continuous voltage UC30 V DC
21 V AC
Nominal current IN300 mA (40°C)
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 10 µA
Nominal discharge current In (8/20) µs (Core-Core)5 kA
Nominal discharge current In (8/20) µs (Core-Earth)5 kA
Pulse discharge current Iimp (10/350) µs (core-ground)500 A
Nominal pulse current Ian (10/1000) µs (Core-Earth)30 A
Impulse discharge current (10/350)˽µs, peak value limp500 A
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 45 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 45 V
Residual voltage at In (conductor-ground)≤ 45 V
Residual voltage with Ian (10/1000)µs (conductor-ground)≤ 50 V
Voltage protection level Up (core-ground)≤ 55 V (C1 - 500 V / 250 A)
≤ 85 V (C2 - 10 kV/5 kA)
Response time tA (Core-Earth)≤ 1 ns
Input attenuation aE, asym.typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
typ. 0.2 dB (≤ 400 kHz / 150 Ω)
Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm systemtyp. 6 MHz
Cut-off frequency fg (3 dB), asym. (PE) in 150 Ohm systemtyp. 2.5 MHz
Capacity (Core-Earth)< 2.5 nF
Resistance in series4.7 Ω ±20 %
Max. required back-up fuse315 mA (e.g. T in acc. with IEC 127-2/III)
Impulse durability (conductor-ground)C1 - 500 V / 250 A
C2 - 10 kV/5 kA
D1 - 500 A

Connection data

Connection methodScrew connection
Connection type INScrew terminal blocks
Connection type OUTScrew terminal blocks
Screw threadM3
Tightening torque0.6 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2920722-TT-2/2-M-24DC English 301 Kbytes PHOENIX CONTACT-2920722-TT-2/2-M-24DC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review